Literature DB >> 24077918

Low aseptic loosening and revision rate in Zweymüller-Plus total hip arthroplasty with ceramic-on-ceramic bearings.

T Bouras1, T Repantis, P Fennema, P Korovessis.   

Abstract

UNLABELLED: A recent comparative study reported lower revision rate and higher survival in ceramic-on-ceramic (CoC) than in metal-on-metal (MoM) coupling in Zweymüller-Plus THA. We retrospectively studied 87 consecutive patients (94 hips), who primarily received Zweymüller-Plus THA (SL-Plus stem, ceramic 28-mm ball head, Bicon cup) with third-generation CoC bearing surfaces for osteoarthritis. Survival, revision and osteolysis rate were studied and compared to those observed in historical series from this institution with the same THA and MoM articulation. The mean ± SD follow-up was 7.4 ± 1.7 years (range 6-10 years). Four hips (4%) in four patients were revised 1-6 years following primary implantation: one (1%) for aseptic loosening of SL-Plus stem and Bicon 5 years after index surgery; one (1%) for malpositioning of the Bicon and recurrent dislocations 1 year following implantation; and two (2%) for septic loosening 1 and 6 years postoperatively. Intraoperatively on inspection, there were neither findings for impingement in the revised hips, nor fracture of the Bicon ceramic inlay and ball head. Expansile osteolysis was shown around SL-Plus stem and Bicon in the revised for aseptic loosening hip. With revision of any component for aseptic loosening as the endpoint, the survival was 99% (95% CI 91-100%), while for revision for any reason, it was 95% (95% CI 87-98%) at 10 years. Zweymüller-Plus THA with CoC bearings showed, at mid-term follow-up, high survival and low revision rate for aseptic loosening. These rates were better than the historical series of the same THA with MoM articulation performed by the same surgeon. LEVEL OF EVIDENCE: Level IV.

Entities:  

Mesh:

Year:  2014        PMID: 24077918     DOI: 10.1007/s00590-013-1314-y

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  30 in total

1.  High medium-term survivorship and durability of Zweymüller-Plus total hip arthroplasty.

Authors:  Panagiotis Korovessis; Thomas Repantis; Andreas Zafiropoulos
Journal:  Arch Orthop Trauma Surg       Date:  2010-08-19       Impact factor: 3.067

2.  Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up.

Authors:  P Korovessis; G Petsinis; M Repanti; T Repantis
Journal:  J Bone Joint Surg Am       Date:  2006-06       Impact factor: 5.284

3.  Validating and norming of the Greek SF-36 Health Survey.

Authors:  Evelina Pappa; Nick Kontodimopoulos; Dimitris Niakas
Journal:  Qual Life Res       Date:  2005-06       Impact factor: 4.147

4.  Fracture of ceramic heads in total hip replacement.

Authors:  B Habermann; W Ewald; M Rauschmann; L Zichner; A A Kurth
Journal:  Arch Orthop Trauma Surg       Date:  2006-06-21       Impact factor: 3.067

5.  Patterns of osteolysis around total hip components inserted with and without cement.

Authors:  B Zicat; C A Engh; E Gokcen
Journal:  J Bone Joint Surg Am       Date:  1995-03       Impact factor: 5.284

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

Review 7.  Ceramic femoral head retrieval data.

Authors:  G Willmann
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

8.  Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.

Authors:  Jeong Joon Yoo; Young-Min Kim; Kang Sup Yoon; Kyung-Hoi Koo; Won Seok Song; Hee Joong Kim
Journal:  J Bone Joint Surg Am       Date:  2005-03       Impact factor: 5.284

9.  Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty.

Authors:  Kyung-Hoi Koo; Yong-Chan Ha; Woon Hwa Jung; Sang-Rim Kim; Jeong Joon Yoo; Hee Joong Kim
Journal:  J Bone Joint Surg Am       Date:  2008-02       Impact factor: 5.284

10.  Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty.

Authors:  P J Lusty; C C Tai; R P Sew-Hoy; W L Walter; W K Walter; B A Zicat
Journal:  J Bone Joint Surg Am       Date:  2007-12       Impact factor: 5.284

View more
  1 in total

1.  Aseptic Loosening after Total Hip Arthroplasty in an Acromegalic Patient: A Case Report.

Authors:  Simon Koulischer; Bilal Kapanci; Nicolas Bloemers; Tatiana Charles; Marc Jayankura
Journal:  J Orthop Case Rep       Date:  2017 Mar-Apr
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.