Literature DB >> 16810547

Fracture of ceramic heads in total hip replacement.

B Habermann1, W Ewald, M Rauschmann, L Zichner, A A Kurth.   

Abstract

After introduction of ceramics in total hip replacement, there have been several studies on wear and fracture of the femoral head component. Though reports on fractures are few, we saw four fractures within 2 months. In all patients, a cementless hip prosthesis by four different surgeons was implanted between 3/2001 and 2/2004. In three patients, a ceramic-on-polyethylene pair and in one, a ceramic-on-ceramic pair was used. Only one patient suffered an adequate trauma. The mean survival of the ceramic head was 27 months (11-42). In two patients with polyethylene inlays, the inlay showed signs of wear out due to the fractured head. All four revision surgeries had a good outcome with satisfying results and no complications. Though we observe the postoperative development after implantation of ceramic components closely, we still believe that ceramics in total hip replacement in young and active patients are indicated with good long term results.

Entities:  

Mesh:

Year:  2006        PMID: 16810547     DOI: 10.1007/s00402-006-0173-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  13 in total

1.  Imaging of ceramic liner fractures in total hip arthroplasty: the value of CT.

Authors:  Yoshimi Endo; Lisa Renner; Tom Schmidt-Braekling; Douglas N Mintz; Friedrich Boettner
Journal:  Skeletal Radiol       Date:  2015-03-07       Impact factor: 2.199

2.  Low aseptic loosening and revision rate in Zweymüller-Plus total hip arthroplasty with ceramic-on-ceramic bearings.

Authors:  T Bouras; T Repantis; P Fennema; P Korovessis
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-12

3.  Effect of Operation Room Nursing Intervention and Ceramic Prosthesis on Total Hip Arthroplasty.

Authors:  Ting Xu; Jie Zhang
Journal:  Scanning       Date:  2022-06-21       Impact factor: 1.750

Review 4.  [The problem of fractures of ceramic heads. What should be done?].

Authors:  H R Dürr
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

5.  Ceramic head fracture in ceramic-on-polyethylene total hip arthroplasty.

Authors:  Jae-Hwi Nho; Jong-Seok Park; Ui-Seoub Song; Woo-Jong Kim; You-Sung Suh
Journal:  Yonsei Med J       Date:  2013-11       Impact factor: 2.759

Review 6.  Ceramic-Ceramic Bearing: Too Unpredictable to Use it Regularly.

Authors:  Edwin P Su
Journal:  HSS J       Date:  2012-09-05

7.  Comparison of the risk of revision in cementless total hip arthroplasty with ceramic-on-ceramic and metal-on-polyethylene bearings.

Authors:  Claus Varnum; Alma B Pedersen; Per Kjærsgaard-Andersen; Søren Overgaard
Journal:  Acta Orthop       Date:  2015-01-30       Impact factor: 3.717

8.  Two-year follow-up of revision total hip arthroplasty using a ceramic revision head with a retained well-fixed femoral component: a case series.

Authors:  Dirk Ganzer; Lutz Forke; Ulrich Irlenbusch
Journal:  J Med Case Rep       Date:  2014-12-17

9.  Traumatic ceramic femoral head fracture: an initial misdiagnosis.

Authors:  Mohammad H Fard-Aghaie; Mustafa Citak; Joao Correia; Carl Haasper; Thorsten Gehrke; Daniel Kendoff
Journal:  Open Orthop J       Date:  2012-08-10

Review 10.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.