| Literature DB >> 24061966 |
Jarle Sundseth1, Eva A Jacobsen, Frode Kolstad, Oystein P Nygaard, John A Zwart, Per K Hol.
Abstract
PURPOSE: Cervical disc prostheses induce significant amount of artifact in magnetic resonance imaging which may complicate radiologic follow-up after surgery. The purpose of this study was to investigate as to what extent the artifact, induced by the frequently used Discover(®) cervical disc prosthesis, impedes interpretation of the MR images at operated and adjacent levels in 1.5 and 3 Tesla MR.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24061966 PMCID: PMC3804698 DOI: 10.1007/s00586-013-2994-z
Source DB: PubMed Journal: Eur Spine J ISSN: 0940-6719 Impact factor: 3.134
Fig. 1a Left 1.5 T MRI with T2 sagittal images. Right 1.5 T MRI with T2 sagittal images and with an artists illustration of the artifact around the disc prosthesis and effect on the spinal cord (illustrated in yellow). The artifact gives the impression that the spinal cord is pulled in the anterior direction towards the disc space/prosthesis and with a change in configuration. b Left 3 T with T2 sagittal images. Right 3 T with T2 sagittal images and with an artists illustration of the artifact around the disc prosthesis and effect on the spinal cord (illustrated in yellow) The artifact gives the impression that the spinal cord is dislocated in the posterior direction and with a signal change within the cord. The artifact can be misinterpreted as spinal stenosis
Disc levels possible to assess with 1.5 and 3 T MRI
| Evaluated level | Sagittal T2 | Axial Medic 2 | Axial T2a | Sagittal T2 | Axial T2 | Oblique T2 | Oblique T2 |
|---|---|---|---|---|---|---|---|
| 1.5 T | 1.5 T | 1. 5 T | 3 T | 3 T | 1.5 T | 3 T | |
|
| 10 | 10 | 1 | 10 | 10 | 10 | 10 |
| Adjacent upper level | 10 | 10 | 1 | 10 | 10 | 10 | 10 |
| Operated level spinal cord | 0 | 0 | 0 | 0 | 0 | – | – |
| Disc | 0 | 0 | 0 | 0 | 0 | – | – |
| Right foramen | – | 0 | 1 | – | 1 | 1 | 0 |
| Left foramen | – | 0 | 1 | – | 2 | 3 | 1 |
| Adjacent lower level | 10 | 10 | 1 | 10 | 10 | 10 | 10 |
The number indicating how many adjacent upper and lower levels and operated level spinal cord, disc, right and left foramina that was possible to evaluate with the different imaging sequences
N number of patients, – not evaluated
a T2 axial 1.5 T was only performed in one patient and the root canals were evaluable at operated level in this patient
Fig. 3a 1.5 T oblique view showing the artifact at operated level C5/C6 and adjacent upper and lower-level root canals. b 3 T oblique view showing the artifact at operated level C5/C6 and adjacent upper and lower-level root canals
Fig. 2Left a and b T1 sagittal images (a 1.5 T and b 3 T) with the hight of the artifact and the hight between the upper and lower endplate for the two adjacent vertebrae shown with lines. Right a and b the artists illustration of the amount of artifact produced around the titanium prostheses in a 1.5 and b 3 T MRI. The artifact ratios were calculated by measuring the hight of the artifact cranial and caudal to the prostheses measured at the center of the vertebrae divided with the hight between the upper and lower endplate for the two adjacent vertebrae