Magnetic resonance imaging evaluation of adjacent segments after cervical disc arthroplasty: magnet strength and its effect on image quality. Clinical article.

Ivan J Antosh1, John G DeVine, Clyde T Carpenter, Brian J Woebkenberg, Stephen M Yoest.   

Abstract

OBJECT: Disc arthroplasty is an alternative to fusion following anterior discectomy when treating either cervical radiculopathy or myelopathy. Its theoretical benefits include preservation of the motion segment and the potential prevention of adjacent-segment degeneration. There is a paucity of data regarding the ability to use MR imaging to evaluate the adjacent segments. The purpose of this study was for the authors to introduce open MR imaging as an alternative method in imaging adjacent segments following cervical disc arthroplasty using a Co-Cr implant and to report their preliminary results using this technique.
METHODS: Postoperative cervical MR images were obtained in the first 16 patients in whom the porous coated motion (PCM-V) cervical arthroplasty system was used to treat a single level between C-3 and C-7. Imaging was performed in all 16 patients with a closed 1.5-T unit, and in the final 6 patients it was also performed with an open 0.2-T unit. All images were evaluated by an independent radiologist observer for the ability to visualize the superior endplate, disc space, and inferior endplate at the superior and inferior adjacent levels.
RESULTS: Utilizing the 1.5-T magnet to assess the superior adjacent level, the superior endplate, disc space, and inferior endplate could each be visualized less than 50% of the time on sagittal T1- and sagittal and axial T2-weighted images. Similarly, the inferior adjacent level structures were adequately visualized less than 50% of the time, with the exception of slightly improved visualization of the inferior endplate on T1-weighted images (56%). Axial images allowed worse visualization than sagittal images at both the superior and inferior adjacent levels. Utilizing the 0.2-T magnet to assess the superior and inferior adjacent levels, the superior endplate, disc space, and inferior endplate were adequately visualized in 100% of images.
CONCLUSIONS: Based on the results of this case series, it appears that the strength of the magnet affects the artifact from the Co-Cr endplates. The open 0.2-T MR imaging unit reduces artifact at adjacent levels after cervical disc arthroplasty without a significant reduction in the image quality. Magnetic resonance imaging can be used to evaluate the adjacent segments after disc arthroplasty if magnet strength is addressed, providing another means to assess the long-term efficacy of this novel treatment.

Entities:  

Mesh:

Year:  2010        PMID: 21121749     DOI: 10.3171/2010.5.SPINE09721

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  5 in total

Review 1.  Cervical and lumbar spinal arthroplasty: clinical review.

Authors:  T D Uschold; D Fusco; R Germain; L M Tumialan; S W Chang
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

2.  Outcomes of the Bryan cervical disc replacement: fifteen year follow-up.

Authors:  Vincent Pointillart; Jean-Etienne Castelain; Pierre Coudert; Derek Thomas Cawley; Olivier Gille; Jean-Marc Vital
Journal:  Int Orthop       Date:  2017-12-29       Impact factor: 3.075

3.  What are the associative factors of adjacent segment degeneration after anterior cervical spine surgery? Comparative study between anterior cervical fusion and arthroplasty with 5-year follow-up MRI and CT.

Authors:  Jeong Yoon Park; Kyung Hyun Kim; Sung Uk Kuh; Dong Kyu Chin; Keun Su Kim; Yong Eun Cho
Journal:  Eur Spine J       Date:  2012-12-15       Impact factor: 3.134

4.  A case of cervical metastases in a patient with preexisting cervical disc replacement and fusion after 2-year symptom-free interval: when do we need interdisciplinary diagnostics?

Authors:  Markus Melloh; Thomas Barz
Journal:  Evid Based Spine Care J       Date:  2012-08

5.  Magnetic resonance imaging evaluation after implantation of a titanium cervical disc prosthesis: a comparison of 1.5 and 3 Tesla magnet strength.

Authors:  Jarle Sundseth; Eva A Jacobsen; Frode Kolstad; Oystein P Nygaard; John A Zwart; Per K Hol
Journal:  Eur Spine J       Date:  2013-09-06       Impact factor: 3.134

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.