Literature DB >> 12594756

Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).

Juergen Hennig1, Matthias Weigel, Klaus Scheffler.   

Abstract

A variation of the rapid acquisition with relaxation enhancement (RARE) sequence (also called turbo spin-echo (TSE) or fast spin-echo (FSE)) is presented. This technique uses variable flip angles along the echo train such that magnetization is initially prepared into the static pseudo steady state (PSS) for a low refocusing flip angle (alpha < 180 degrees ). It is shown that after such a preparation, magnetization will always stay very close to the static PSS even after significant variation of the subsequent refocusing flip angles. This allows the design of TSE sequences in which high refocusing flip angles yielding 100% of the attainable signal are applied only for the important echoes encoding for the center of k-space. It is demonstrated that a reduction of the RF power (RFP) by a factor of 2.5-6 can be achieved without any loss in signal intensity. The contribution of stimulated-echo pathways leads to a reduction of the effective TE by a factor f(t), which for typical implementations is on the order of 0.5-0.8. This allows the use of longer echo readout times, and thus longer echo trains, for acquiring images with a given T(2) contrast. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 12594756     DOI: 10.1002/mrm.10391

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  62 in total

1.  Optimization of 3D-variable refocusing flip angle RARE imaging for high-resolution volumetric black-blood angiography.

Authors:  Masami Yoneyama; Masanobu Nakamura; Takashi Tabuchi; Atsushi Takemura; Makoto Obara
Journal:  Radiol Phys Technol       Date:  2012-06-20

Review 2.  In vivo structural imaging of the cerebellum, the contribution of ultra-high fields.

Authors:  José P Marques; Rolf Gruetter; Wietske van der Zwaag
Journal:  Cerebellum       Date:  2012-06       Impact factor: 3.847

Review 3.  Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives.

Authors:  Nicolae Bolog; Daniel Nanz; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

4.  Hyperecho-turbo spin-echo sequences at 3T: clinical application in neuroradiology.

Authors:  R H Tetzlaff; I Mader; W Küker; J Weber; S Ziyeh; A Schulze-Bonhage; J Hennig; M Weigel
Journal:  AJNR Am J Neuroradiol       Date:  2008-03-05       Impact factor: 3.825

5.  Sparse and optimal acquisition design for diffusion MRI and beyond.

Authors:  Cheng Guan Koay; Evren Ozarslan; Kevin M Johnson; M Elizabeth Meyerand
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

6.  Simple method for whole-brain volumetric T(1)-weighted turbo spin-echo imaging.

Authors:  Masami Yoneyama; Masanobu Nakamura; Makoto Obara; Takashi Namiki; Atsushi Takemura; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-12-04

7.  RARE/turbo spin echo imaging with Simultaneous Multislice Wave-CAIPI.

Authors:  Borjan A Gagoski; Berkin Bilgic; Cornelius Eichner; Himanshu Bhat; P Ellen Grant; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2015-02-02       Impact factor: 4.668

8.  Automated patient-specific optimization of three-dimensional double-inversion recovery magnetic resonance imaging.

Authors:  Refaat E Gabr; Xiaojun Sun; Amol S Pednekar; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

9.  Increased Speed and Image Quality for Pelvic Single-Shot Fast Spin-Echo Imaging with Variable Refocusing Flip Angles and Full-Fourier Acquisition.

Authors:  Andreas M Loening; Daniel V Litwiller; Manojkumar Saranathan; Shreyas S Vasanawala
Journal:  Radiology       Date:  2016-08-26       Impact factor: 11.105

10.  MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence.

Authors:  Koichi Takano; Shinnichi Yamashita; Koichiro Takemoto; Tooru Inoue; Yasuo Kuwabara; Kengo Yoshimitsu
Journal:  Neuroradiology       Date:  2013-04-26       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.