Relation between radiological assessment and biomechanical stability of lumbar interbody fusion in a large animal model.

R J Kroeze1, A J van der Veen, B J van Royen, R A Bank, M N Helder, T H Smit.   

Abstract

PURPOSE: To relate the progress of vertebral segmental stability after interbody fusion surgery with radiological assessment of spinal fusion.
METHODS: Twenty goats received double-level interbody fusion and were followed for a period of 3, 6 and 12 months. After killing, interbody fusion was assessed radiographically by two independent observers. Subsequently, the lumbar spines were subjected to four-point bending and rotational deformation, assessed with an optoelectronic 3D movement registration system. In addition, four caprine lumbar spines were analysed in both the native situation and after the insertion of a cage device, as to mimic the direct post-surgical situation. The range of motion (ROM) in flexion/extension, lateral bending and axial rotation was analysed ex vivo using a multi-segment testing system.
RESULTS: Significant reduction in ROM in the operated segments was already achieved with moderate bone ingrowth in flexion/extension (71 % reduction in ROM) and with only limited bone ingrowth in lateral bending (71 % reduction in ROM) compared to the post-surgical situation. The presence of a sentinel sign always resulted in a stable vertebral segment in both flexion/extension and lateral bending. For axial rotation, the ROM was already limited in both native and cage inserted situations, resulting in non-significant differences for all radiographic scores. DISCUSSION: In vivo vertebral segment stability, defined as a significant reduction in ROM, is achieved in an early stage of spinal fusion, well before a radiological bony fusion between the vertebrae can be observed. Therefore, plain radiography underestimates vertebral segment stability.

Entities:  

Mesh:

Year:  2013        PMID: 24043338      PMCID: PMC3843781          DOI: 10.1007/s00586-013-3003-2

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  26 in total

Review 1.  Biomechanics of stand-alone cages and cages in combination with posterior fixation: a literature review.

Authors:  T R Oxland; T Lund
Journal:  Eur Spine J       Date:  2000-02       Impact factor: 3.134

2.  [Biomechanicsl evaluation of a stand-alone interbody fusion cage based on porous TiO2/glass-ceramic on the human cervical spine].

Authors:  M C Korinth; S Moersch; C Ragoss; E Schopphoff
Journal:  Biomed Tech (Berl)       Date:  2003-12       Impact factor: 1.411

3.  Comparison of stabilities between obliquely and conventionally inserted Bagby and Kuslich cages as posterior lumbar interbody fusion in a cadaver model.

Authors:  Shih-Tien Wang; Vijay K Goel; Shinichiro Kubo; Woosung Choi; Justin K Coppes; Chien-Lin Liu; Tain-Hsiung Chen
Journal:  J Chin Med Assoc       Date:  2003-11       Impact factor: 2.743

4.  Biomechanical characteristics of different regions of the human spine: an in vitro study on multilevel spinal segments.

Authors:  Iris Busscher; Jaap H van Dieën; Idsart Kingma; Albert J van der Veen; Gijsbertus J Verkerke; Albert G Veldhuizen
Journal:  Spine (Phila Pa 1976)       Date:  2009-12-15       Impact factor: 3.468

Review 5.  Biomechanics of fusion and stabilization.

Authors:  V K Goel; M H Pope
Journal:  Spine (Phila Pa 1976)       Date:  1995-12-15       Impact factor: 3.468

6.  Flexibility analysis of posterolateral fusions in a New Zealand white rabbit model.

Authors:  J S Erulkar; J N Grauer; T C Patel; M M Panjabi
Journal:  Spine (Phila Pa 1976)       Date:  2001-05-15       Impact factor: 3.468

7.  The use of poly-L-lactic acid in lumbar interbody cages: design and biomechanical evaluation in vitro.

Authors:  Martijn van Dijk; Theo H Smit; Maurice F Arnoe; Elisabeth H Burger; Paul I Wuisman
Journal:  Eur Spine J       Date:  2002-09-06       Impact factor: 3.134

8.  The effect of ethylene oxide, glow discharge and electron beam on the surface characteristics of poly(L-lactide-co-caprolactone) and the corresponding cellular response of adipose stem cells.

Authors:  R J Kroeze; M N Helder; W H Roos; G J L Wuite; R A Bank; T H Smit
Journal:  Acta Biomater       Date:  2009-11-26       Impact factor: 8.947

Review 9.  Interbody cage devices.

Authors:  Thomas A Zdeblick; Frank M Phillips
Journal:  Spine (Phila Pa 1976)       Date:  2003-08-01       Impact factor: 3.468

10.  Interbody device footprint and endplate engagement characteristics: biomechanical implications.

Authors:  Edward C Benzel
Journal:  Spine J       Date:  2009-07       Impact factor: 4.166

View more
  4 in total

1.  Importance of the epiphyseal ring in OLIF stand-alone surgery: a biomechanical study on cadaveric spines.

Authors:  Xuyang Zhang; Hao Wu; Yilei Chen; Junhui Liu; Jian Chen; Teng Zhang; ZhaoFeng Zhou; Shunwu Fan; Patricia Dolan; Michael Anthony Adams; Fengdong Zhao
Journal:  Eur Spine J       Date:  2020-11-23       Impact factor: 3.134

2.  Spinal fusion using adipose stem cells seeded on a radiolucent cage filler: a feasibility study of a single surgical procedure in goats.

Authors:  Robert J Kroeze; Theo H Smit; Pieter P Vergroesen; Ruud A Bank; Reinout Stoop; Bert van Rietbergen; Barend J van Royen; Marco N Helder
Journal:  Eur Spine J       Date:  2014-11-25       Impact factor: 3.134

3.  Two-year results of a double-blind multicenter randomized controlled non-inferiority trial of polyetheretherketone (PEEK) versus silicon nitride spinal fusion cages in patients with symptomatic degenerative lumbar disc disorders.

Authors:  Bryan J McEntire; Greg Maslin; B Sonny Bal
Journal:  J Spine Surg       Date:  2020-09

4.  MagnetOs, Vitoss, and Novabone in a Multi-endpoint Study of Posterolateral Fusion: A True Fusion or Not?

Authors:  Lukas A van Dijk; Florence Barrère-de Groot; Antoine J W P Rosenberg; Matthew Pelletier; Chris Christou; Joost D de Bruijn; William R Walsh
Journal:  Clin Spine Surg       Date:  2020-07       Impact factor: 1.723

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.