Literature DB >> 14740523

[Biomechanicsl evaluation of a stand-alone interbody fusion cage based on porous TiO2/glass-ceramic on the human cervical spine].

M C Korinth1, S Moersch, C Ragoss, E Schopphoff.   

Abstract

Recently, there has been a rapid increase in the use of cervical spine interbody fusion cages, differing in design and biomaterial used, in competition to autologous iliac bone graft and bone cement (PMMA). Limited biomechanical differences in primary stability, as well as advantages and disadvantages of each cage or material have been investigated in studies, using an in vitro human cervical spine model. 20 human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO2/glass composite (Ecopore) or PMMA after discectomy. Non-destructive biomechanical testing was performed, including flexion/extension and lateral bending using a spine testing apparatus. Three-dimensional segmental range of motion (ROM) was evaluated using an ultrasound measurement system. ROM increased more in flexion/extension and lateral bending after PMMA fusion (26.5%/36.1%), then after implantation of the Ecopore-cage (8.1%/7.8%). In this first biomechanical in vitro examination of a new porous ceramic bone replacement material a) the feasibility and reproducibility of biomechanical cadaveric cervical examination and its applicability was demonstrated, b) the stability of the ceramic cage as a stand alone interbody cage was confirmed in vitro, and c) basic information and knowledge for our intended biomechanical and histological in vivo testing, after implantation of Ecopore in cervical sheep spines, were obtained.

Entities:  

Mesh:

Year:  2003        PMID: 14740523     DOI: 10.1515/bmte.2003.48.12.349

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  2 in total

1.  Relation between radiological assessment and biomechanical stability of lumbar interbody fusion in a large animal model.

Authors:  R J Kroeze; A J van der Veen; B J van Royen; R A Bank; M N Helder; T H Smit
Journal:  Eur Spine J       Date:  2013-09-17       Impact factor: 3.134

Review 2.  Factors influencing surgical outcome after anterior stabilization of the cervical spine with heterogeneous material.

Authors:  Athanasios K Petridis; Sabrina Sechting; Michael Budde; Alexandros Doukas; Homajoun Maslehaty; Hubertus Maximilian Mehdorn
Journal:  Clin Pract       Date:  2012-05-29
  2 in total