Literature DB >> 24036922

Discrepancies between Doppler and catheter gradients in ventricular septal defect: a correction of localized gradients from pressure recovery phenomenon.

Taylan Akgun1, Can Yücel Karabay, Gonenc Kocabay, Vecih Oduncu, Arzu Kalayci, Ahmet Guler, Olcay Ozveren, Fatih Yilmaz, Mustafa Akcakoyun, Cevat Kirma.   

Abstract

Although very high gradient levels were measured during the evaluation of ventricular septal defect (VSD) in daily practice, these measurements are generally interpreted as erroneous and thus neglected. Our aim was to assess the features of VSD's having erroneous interventricular pressure gradients by echocardiography. A 46 patients were enrolled in the study. The patients with higher Doppler-derived interventricular gradient than brachial systolic blood pressure were compared with patients with lower gradient (group 1, n = 26; group 2, n = 20, respectively) in terms of echocardiographic characteristics of VSD. No significant relations were observed in systolic and diastolic blood pressure and interventricular synchronicity between two groups (117.1 ± 6.7 vs 110.2 ± 6.3 mmHg, p = 0.145; 74.7 ± 4.3 vs 73.2 ± 4.9 mmHg, p = 0.32; 31.2 ± 5.5 vs 33.2 ± 4.9 msn, p = 0.29, respectively). Left ventricular end-diastolic and end-systolic diameters were greater in group 2 (46.6 ± 3.5 vs 49.5 ± 4.5, p = 0.022; 30.3 ± 2.5 vs 32.9 ± 3.2, p = 0.004, respectively). Doppler-derived interventricular pressure gradients were significantly higher in group 1 (144.4 ± 13.6 vs 75.7 ± 5.1 mmHg, p < 0.001, respectively). Defect width was significantly lower (3.20 ± 0.40 vs 4.8 ± 1.8 mm, respectively, p < 0.05), and length was greater in group 1 patients (5.75 ± 0.90 vs 2.80 ± 0.80 mm, p < 0.05, respectively). There was a significant positive correlation between pressure gradient and defect length (r = 0.84, p < 0.001), and a negative correlation between pressure gradient and defect width (r = -0.66, p < 0.001). Defect length/width was significantly greater in group 1. With the cut-off value of 1.2, defect length/width was able to predict tunnel-type VSD with sensitivity of 88.5% and specificity of 72.7%. Continuous-wave Doppler method may overestimate interventricular pressure gradients in patients with tunnel-type ventricular septal defect.

Entities:  

Mesh:

Year:  2013        PMID: 24036922     DOI: 10.1007/s10554-013-0291-x

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  16 in total

1.  Comparison of simultaneous invasive and noninvasive measurements of pressure gradients in congenital aortic valve stenosis.

Authors:  Piers C A Barker; Gregory Ensing; Achiau Ludomirsky; David J Bradley; Thomas R Lloyd; Albert P Rocchini
Journal:  J Am Soc Echocardiogr       Date:  2002-12       Impact factor: 5.251

2.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice.

Authors:  Helmut Baumgartner; Judy Hung; Javier Bermejo; John B Chambers; Arturo Evangelista; Brian P Griffin; Bernard Iung; Catherine M Otto; Patricia A Pellikka; Miguel Quiñones
Journal:  J Am Soc Echocardiogr       Date:  2009-01       Impact factor: 5.251

3.  Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery.

Authors:  H Baumgartner; S Khan; M DeRobertis; L Czer; G Maurer
Journal:  Circulation       Date:  1990-10       Impact factor: 29.690

4.  Importance of pressure recovery for the assessment of aortic stenosis by Doppler ultrasound. Role of aortic size, aortic valve area, and direction of the stenotic jet in vitro.

Authors:  J Niederberger; H Schima; G Maurer; H Baumgartner
Journal:  Circulation       Date:  1996-10-15       Impact factor: 29.690

5.  Intraoperative Doppler echocardiography in hypertrophic cardiomyopathy: correlations with the obstructive gradient.

Authors:  W J Stewart; W A Schiavone; E E Salcedo; H M Lever; D M Cosgrove; C C Gill
Journal:  J Am Coll Cardiol       Date:  1987-08       Impact factor: 24.094

6.  Effect of stenosis geometry on the Doppler-catheter gradient relation in vitro: a manifestation of pressure recovery.

Authors:  H Baumgartner; H Schima; G Tulzer; P Kühn
Journal:  J Am Coll Cardiol       Date:  1993-03-15       Impact factor: 24.094

7.  Ventricular septal defects in adults.

Authors:  N M Ammash; C A Warnes
Journal:  Ann Intern Med       Date:  2001-11-06       Impact factor: 25.391

8.  Illustration of the additional value of real-time 3-dimensional echocardiography to conventional transthoracic and transesophageal 2-dimensional echocardiography in imaging muscular ventricular septal defects: does this have any impact on individual patient treatment?

Authors:  Laura Mercer-Rosa; Mohamed A Seliem; Anysia Fedec; Jonathan Rome; Jack Rychik; J William Gaynor
Journal:  J Am Soc Echocardiogr       Date:  2006-12       Impact factor: 5.251

9.  Doppler echocardiographic estimation of systolic pulmonary artery pressure in pediatric patients with interventricular communications.

Authors:  G R Marx; H D Allen; S J Goldberg
Journal:  J Am Coll Cardiol       Date:  1985-11       Impact factor: 24.094

10.  Continuous-wave Doppler velocities and gradients across fixed tunnel obstructions: studies in vitro and in vivo.

Authors:  A P Yoganathan; L M Valdes-Cruz; J Schmidt-Dohna; A Jimoh; C Berry; T Tamura; D J Sahn
Journal:  Circulation       Date:  1987-09       Impact factor: 29.690

View more