Literature DB >> 17138037

Illustration of the additional value of real-time 3-dimensional echocardiography to conventional transthoracic and transesophageal 2-dimensional echocardiography in imaging muscular ventricular septal defects: does this have any impact on individual patient treatment?

Laura Mercer-Rosa1, Mohamed A Seliem, Anysia Fedec, Jonathan Rome, Jack Rychik, J William Gaynor.   

Abstract

OBJECTIVE: We sought to answer the question of whether the additional morphologic details obtained by real-time 3-dimensional (3D) echocardiographic (RT3DE) imaging of muscular ventricular septal defect (VSD) has any significant impact on treatment options of individual patient.
BACKGROUND: Muscular VSD can be safely and effectively closed by interventional catheterization procedure using VSD devices under transesophageal echocardiographic (TEE) guidance. Recent application of RT3DE has shown great promise for imaging VSD with better display of the exact geometry, size, and location of the defect.
METHODS: Nineteen patients with different types of VSDs were imaged with RT3DE matrix-array transducer; there were 6 cases with muscular VSD. Based on standard transthoracic echocardiographic and TEE imaging, one patient was considered a good candidate for perventricular VSD device occlusion, three patients were considered for surgical closure, and in two patients no intervention was deemed necessary.
RESULTS: RT3DE successfully displayed the exact morphology of the VSD in all 6 patients, whereas transthoracic echocardiography and TEE showed the defect as a dropout with variable diameter in different views. Such planer images did not accurately predict the exact morphology in the patient in whom device occlusion was considered and the device embolized to the left ventricle in a few heartbeats. Surgical circular patch was used in two patients and primary suture was used in two patients in agreement with the 3D morphology. In two patients the 3D morphology of the VSD was small enough that no intervention was considered.
CONCLUSIONS: RT3DE imaging of muscular VSD can accurately display the exact geometry of the defect, which can have significant impact on treatment strategies of individual patients. This new imaging modality should be an important adjunct to the standard transthoracic echocardiographic and TEE imaging of these defect before any intervention.

Entities:  

Mesh:

Year:  2006        PMID: 17138037     DOI: 10.1016/j.echo.2006.06.015

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  8 in total

1.  3D transesophageal echocardiography is a decision-making tool for the management of cardiogenic shock following a large postinfarction ventricular defect.

Authors:  Yihua Liu; Zied Frikha; Pablo Maureira; Bruno Levy; Christine Selton-Suty; Jean-pierre Villemot; Olivier Huttin
Journal:  J Cardiothorac Surg       Date:  2015-01-21       Impact factor: 1.637

2.  Three dimensional echocardiography in congenital heart defects.

Authors:  Girish S Shirali
Journal:  Ann Pediatr Cardiol       Date:  2008-01

3.  Perventricular closure of muscular ventricular septal defects: How do I do it?

Authors:  Karim A Diab; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Ann Pediatr Cardiol       Date:  2008-01

4.  The Changing Paradigm in the Treatment of Structural Heart Disease and the Need for the Interventional Imaging Specialist.

Authors:  Nina C Wunderlich; Harald Küx; Felix Kreidel; Ralf Birkemeyer; Robert J Siegel
Journal:  Interv Cardiol       Date:  2016-10

5.  Discrepancies between Doppler and catheter gradients in ventricular septal defect: a correction of localized gradients from pressure recovery phenomenon.

Authors:  Taylan Akgun; Can Yücel Karabay; Gonenc Kocabay; Vecih Oduncu; Arzu Kalayci; Ahmet Guler; Olcay Ozveren; Fatih Yilmaz; Mustafa Akcakoyun; Cevat Kirma
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-14       Impact factor: 2.357

6.  Transthoracic closure of ventricular septal defects guided by transesophageal echocardiography.

Authors:  Huang Jiang-Shan; Sun Kai-Peng; Xu Ning; Zhang Gui-Can; Chen Qiang
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2020-04-22       Impact factor: 0.332

Review 7.  Three-dimensional echocardiography in adult congenital heart disease.

Authors:  Hyun Suk Yang
Journal:  Korean J Intern Med       Date:  2017-06-30       Impact factor: 2.884

Review 8.  Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function-Current Clinical Applications and Literature Review Update.

Authors:  Omar Velasco; Morgan Q Beckett; Aaron W James; Megan N Loehr; Taylor G Lewis; Tahmin Hassan; Rajesh Janardhanan
Journal:  Biores Open Access       Date:  2017-03-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.