Literature DB >> 2957113

Continuous-wave Doppler velocities and gradients across fixed tunnel obstructions: studies in vitro and in vivo.

A P Yoganathan, L M Valdes-Cruz, J Schmidt-Dohna, A Jimoh, C Berry, T Tamura, D J Sahn.   

Abstract

The simplified Bernoulli relationship appears to be quite accurate for predicting gradients across discrete valvular obstructions. Controversy exists about how accurately it predicts the severity of disease in longer segment obstructions. In this study we constructed a pulsatile model of subvalvular pulmonary stensosis in vitro to study nine custom-made subvalvular tunnels 2, 4, and 7 mm in length with flow cross sections of 0.5 to 1.5 cm2 and with the stenotic segment proximal to a nonstenotic bioprosthetic valve, and a pulsatile model in vitro of a 16 mm long tunnel-like ventricular septal defect (VSD) of varying cross-sectional area (0.20 to 0.64 cm2). We also compared the observations in vitro with those in an open-chest dog preparation with a tunnel-like interventricular communication. In the subpulmonic stenosis model, for each individual tunnel, 10 instantaneous peak gradients between 15 to 105 mm Hg were available. The pressure gradients across the tunnel alone, measured in the subvalvular area, were consistently higher than the measured gradients across the tunnel plus valve, suggesting some relaminarization of flow (i.e., a decrease in velocity) and pressure recovery (i.e., an increase in pressure) distal to the obstruction. Continuous-wave Doppler velocities across the 4 and 7 mm tunnels for the highest gradients were slightly lower than for the 2 mm tunnel at the same gradients, and it was only for the 0.5 cm2 cross section, 4 and 7 mm tunnels that there was a suggestion of minor viscous energy loss. For all the subvalvular tunnels studied, the Bernoulli relationship accurately predicted the results of the pressure drop across the tunnel only, while the gradient across tunnel plus valve was consistently lower. For the VSD tunnel model in vitro, the Doppler-derived gradients were approximately 40% higher than the measured gradients. The findings for the subvalvular and VSD tunnels in vitro and similar findings in the open-chest dogs with VSD suggest that relaminarization of flow and recovery of pressure occurred distal to the tunnel orifice, whereas continuous-wave Doppler findings correlate with the highest instantaneous gradients measured in the lowest pressure areas at the vena contracta of the tunnel.

Entities:  

Mesh:

Year:  1987        PMID: 2957113     DOI: 10.1161/01.cir.76.3.657

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  5 in total

1.  Echocardiographic follow-up of children with isolated discrete subaortic stenosis.

Authors:  Kadir Babaoglu; Ayse Guler Eroglu; Funda Oztunç; Levent Saltik; Tevfik Demir; Gulay Ahunbay; Alper Guzeltas; Gürkan Cetin
Journal:  Pediatr Cardiol       Date:  2006-11-16       Impact factor: 1.655

2.  Velocity measurements with a new ultrasonic Doppler method independent of angle of incidence.

Authors:  Shigeru Akamatsu; Yuji Kondo; Shuji Dohi
Journal:  J Anesth       Date:  1996-06       Impact factor: 2.078

3.  Echocardiographic follow-up of children with supravalvular aortic stenosis.

Authors:  Ayse Guler Eroglu; Kadir Babaoglu; Funda Oztunc; Levent Saltik; Tevfik Demir; Güley Ahunbay; Alper Guzeltas; Gürkan Cetin
Journal:  Pediatr Cardiol       Date:  2006-11-07       Impact factor: 1.655

4.  Discrepancies between Doppler and catheter gradients in ventricular septal defect: a correction of localized gradients from pressure recovery phenomenon.

Authors:  Taylan Akgun; Can Yücel Karabay; Gonenc Kocabay; Vecih Oduncu; Arzu Kalayci; Ahmet Guler; Olcay Ozveren; Fatih Yilmaz; Mustafa Akcakoyun; Cevat Kirma
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-14       Impact factor: 2.357

5.  Relationship between Invasive and Echocardiographic Transvalvular Gradients after Transcatheter Aortic Valve Replacement.

Authors:  Seyed Hossein Aalaei-Andabili; Ki E Park; Calvin Y Choi; Eddie W Manning; Wade W Stinson; Ryan Van Woerkom; Thomas Pilgrim; Dharam J Kumbhani; Anthony A Bavry
Journal:  Cardiol Ther       Date:  2020-01-22
  5 in total