Literature DB >> 24007146

Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery.

Joerg Rottmann1, Paul Keall, Ross Berbeco.   

Abstract

PURPOSE: To provide real-time lung tumor motion estimation during radiotherapy treatment delivery without the need for implanted fiducial markers or additional imaging dose to the patient.
METHODS: 2D radiographs from the therapy beam's-eye-view (BEV) perspective are captured at a frame rate of 12.8 Hz with a frame grabber allowing direct RAM access to the image buffer. An in-house developed real-time soft tissue localization algorithm is utilized to calculate soft tissue displacement from these images in real-time. The system is tested with a Varian TX linear accelerator and an AS-1000 amorphous silicon electronic portal imaging device operating at a resolution of 512 × 384 pixels. The accuracy of the motion estimation is verified with a dynamic motion phantom. Clinical accuracy was tested on lung SBRT images acquired at 2 fps.
RESULTS: Real-time lung tumor motion estimation from BEV images without fiducial markers is successfully demonstrated. For the phantom study, a mean tracking error <1.0 mm [root mean square (rms) error of 0.3 mm] was observed. The tracking rms accuracy on BEV images from a lung SBRT patient (≈20 mm tumor motion range) is 1.0 mm.
CONCLUSIONS: The authors demonstrate for the first time real-time markerless lung tumor motion estimation from BEV images alone. The described system can operate at a frame rate of 12.8 Hz and does not require prior knowledge to establish traceable landmarks for tracking on the fly. The authors show that the geometric accuracy is similar to (or better than) previously published markerless algorithms not operating in real-time.

Entities:  

Mesh:

Year:  2013        PMID: 24007146      PMCID: PMC3772940          DOI: 10.1118/1.4818655

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Real-time tumor motion estimation using respiratory surrogate via memory-based learning.

Authors:  Ruijiang Li; John H Lewis; Ross I Berbeco; Lei Xing
Journal:  Phys Med Biol       Date:  2012-07-06       Impact factor: 3.609

2.  A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup.

Authors:  Christoph Bert; Katherine G Metheany; Karen Doppke; George T Y Chen
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

3.  Accuracy of a wireless localization system for radiotherapy.

Authors:  James M Balter; J Nelson Wright; Laurence J Newell; Barry Friemel; Steven Dimmer; Yuki Cheng; John Wong; Edward Vertatschitsch; Timothy P Mate
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-03-01       Impact factor: 7.038

4.  Online correction for respiratory motion: evaluation of two different imaging geometries.

Authors:  Simeon Nill; Jan Unkelbach; Lars Dietrich; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2005-08-17       Impact factor: 3.609

5.  Use of a realistic breathing lung phantom to evaluate dose delivery errors.

Authors:  Laurence E Court; Joao Seco; Xing-Qi Lu; Kazuyu Ebe; Charles Mayo; Dan Ionascu; Brian Winey; Nikos Giakoumakis; Michalis Aristophanous; Ross Berbeco; Joerg Rottman; Madeleine Bogdanov; Deborah Schofield; Tania Lingos
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

6.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

7.  Correlation of lung tumor motion with external surrogate indicators of respiration.

Authors:  Jeremy D P Hoisak; Katharina E Sixel; Romeo Tirona; Patrick C F Cheung; Jean-Philippe Pignol
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-15       Impact factor: 7.038

8.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates.

Authors:  Ross I Berbeco; Seiko Nishioka; Hiroki Shirato; George T Y Chen; Steve B Jiang
Journal:  Phys Med Biol       Date:  2005-07-28       Impact factor: 3.609

9.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

10.  Intrafractional tumor motion: lung and liver.

Authors:  Hiroki Shirato; Yvette Seppenwoolde; Kei Kitamura; Rikiya Onimura; Shinichi Shimizu
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

View more
  11 in total

1.  Low Z target switching to increase tumor endothelial cell dose enhancement during gold nanoparticle-aided radiation therapy.

Authors:  Ross I Berbeco; Alexandre Detappe; Panogiotis Tsiamas; David Parsons; Mammo Yewondwossen; James Robar
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Registration of clinical volumes to beams-eye-view images for real-time tracking.

Authors:  Jonathan H Bryant; Joerg Rottmann; John H Lewis; Pankaj Mishra; Paul J Keall; Ross I Berbeco
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

3.  A novel EPID design for enhanced contrast and detective quantum efficiency.

Authors:  Joerg Rottmann; Daniel Morf; Rony Fueglistaller; George Zentai; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

4.  The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking.

Authors:  Stephen Yip; Joerg Rottmann; Ross Berbeco
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

5.  A new scheme for real-time high-contrast imaging in lung cancer radiotherapy: a proof-of-concept study.

Authors:  Hao Yan; Zhen Tian; Yiping Shao; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2016-03-04       Impact factor: 3.609

6.  Beam's-eye-view imaging during non-coplanar lung SBRT.

Authors:  Stephen S F Yip; Joerg Rottmann; Ross I Berbeco
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

7.  A novel method for quantification of beam's-eye-view tumor tracking performance.

Authors:  Yue-Houng Hu; Marios Myronakis; Joerg Rottmann; Adam Wang; Daniel Morf; Daniel Shedlock; Paul Baturin; Josh Star-Lack; Ross Berbeco
Journal:  Med Phys       Date:  2017-10-13       Impact factor: 4.071

8.  Technical Note: Synthetic treatment beam imaging for motion monitoring during spine SBRT treatments - a phantom study.

Authors:  Tianfang Li; Feifei Li; Weixing Cai; Pengpeng Zhang; Xiang Li
Journal:  Med Phys       Date:  2020-12-07       Impact factor: 4.071

Review 9.  Stereotactic radiotherapy for early stage non-small cell lung cancer: current standards and ongoing research.

Authors:  Eugenia Vlaskou Badra; Michael Baumgartl; Silvia Fabiano; Aurélien Jongen; Matthias Guckenberger
Journal:  Transl Lung Cancer Res       Date:  2021-04

10.  Clinical translation of a new flat-panel detector for beam's-eye-view imaging.

Authors:  T C Harris; J Seco; D Ferguson; M Lehmann; P Huber; M Shi; M Jacobson; I Valencia Lozano; M Myronakis; P Baturin; R Fueglistaller; D Morf; R Berbeco
Journal:  Phys Med Biol       Date:  2020-12-07       Impact factor: 4.174

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.