Literature DB >> 24005997

Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study.

Yong Hu1, Zhen-shan Yuan, William Ryan Spiker, Todd J Albert, Wei-xin Dong, Hui Xie, Jian-bing Yuan, Cheng-tao Wang.   

Abstract

PURPOSE: The goal of this study is to evaluate the accuracy of patient-specific CT-based rapid prototype drill templates for C2 translaminar screw insertion.
METHODS: Volumetric CT scanning was performed in 32 cadaveric cervical spines. Using computer software, the authors constructed drill templates that fit onto the posterior surface of the C2 vertebrae with drill guides to match the slope of the patient's lamina. Thirty-two physical templates were created from the computer models using a rapid prototyping machine. The drill templates were used to guide drilling of the lamina and post-operative CT images were obtained. The entry point and direction of the planned and inserted screws were measured and compared.
RESULTS: Sixty-four C2 translaminar screws were placed without violating the cortical bone of a single lamina. The bilateral average transverse angle of intended and actual screw for C2TLS was 56.60 ± 2.22°, 56.38 ± 2.51°, 56.65 ± 2.24°, 56.39 ± 2.45°. The bilateral mean coronal angle of the planned and actual screw for C2TLS was 0°, 0°, -0.07 ± 0.32°, 0.12 ± 0.57°. The average displacement of the entry point of the superior and inferior C2TLS in the x, y, z axis was 0.27 ± 0.85, 0.49 ± 1.46, -0.28 ± 0.69, 0.43 ± 0.88, 0.38 ± 1.51, 0.23 ± 0.64 mm.
CONCLUSION: The small deviations seen are likely due to human error in the form of small variations in the surgical technique and use of software to design the prototype. This technology improves the safety profile of this fixation technique and should be further studied in clinical applications.

Entities:  

Mesh:

Year:  2013        PMID: 24005997      PMCID: PMC3843787          DOI: 10.1007/s00586-013-2993-0

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  30 in total

1.  Image-based planning and validation of C1-C2 transarticular screw fixation using personalized drill guides.

Authors:  Johan Van Cleynenbreugel; Filip Schutyser; Jan Goffin; Karel Van Brussel; Paul Suetens
Journal:  Comput Aided Surg       Date:  2002

2.  Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note.

Authors:  Neill M Wright
Journal:  J Spinal Disord Tech       Date:  2004-04

3.  Translaminar rigid screw fixation of the axis. Technical note.

Authors:  Neill M Wright
Journal:  J Neurosurg Spine       Date:  2005-11

4.  Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. Technical note.

Authors:  Jeffrey R Leonard; Neill M Wright
Journal:  J Neurosurg       Date:  2006-01       Impact factor: 5.115

5.  Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.

Authors:  Yoshiharu Kawaguchi; Masato Nakano; Taketoshi Yasuda; Shoji Seki; Takeshi Hori; Tomoatsu Kimura
Journal:  Spine (Phila Pa 1976)       Date:  2012-11-01       Impact factor: 3.468

6.  Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws.

Authors:  Samir B Lapsiwala; Paul A Anderson; Ashish Oza; Daniel K Resnick
Journal:  Neurosurgery       Date:  2006-03       Impact factor: 4.654

7.  Plate and screw fixation for atlanto-axial subluxation.

Authors:  A Goel; V Laheri
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

8.  Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2.

Authors:  J Goffin; K Van Brussel; K Martens; J Vander Sloten; R Van Audekercke; M H Smet
Journal:  Spine (Phila Pa 1976)       Date:  2001-06-15       Impact factor: 3.468

9.  Atlantoaxial fixation using plate and screw method: a report of 160 treated patients.

Authors:  Atul Goel; Ketan I Desai; Dattatraya P Muzumdar
Journal:  Neurosurgery       Date:  2002-12       Impact factor: 4.654

10.  Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation.

Authors:  B Jeanneret; F Magerl
Journal:  J Spinal Disord       Date:  1992-12
View more
  16 in total

1.  Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation.

Authors:  Xiangxue Kong; Lei Tang; Qiang Ye; Wenhua Huang; Jianyi Li
Journal:  Eur Spine J       Date:  2017-07-17       Impact factor: 3.134

2.  Accuracy of a dynamic surgical guidance probe for screw insertion in the cervical spine: a cadaveric study.

Authors:  Daniel Dixon; Bruce Darden; Jose Casamitjana; Karen A Weissmann; San Cristobal; David Powell; Daniel Baluch
Journal:  Eur Spine J       Date:  2016-11-14       Impact factor: 3.134

Review 3.  Cervical screw placement using rapid prototyping drill templates for navigation: a literature review.

Authors:  Teng Lu; Chao Liu; Jun Dong; Meng Lu; Haopeng Li; Xijing He
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-09       Impact factor: 2.924

4.  Lumbar and sacral pedicle screw placement using a template does not improve the midterm pain and disability outcome in comparison with free-hand method.

Authors:  Matjaz Merc; Gregor Recnik; Zmago Krajnc
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-01-19

5.  Freehand power-assisted pedicle screw placement in scoliotic patients: results on 5522 consecutive pedicle screws.

Authors:  C Faldini; F Barile; G Viroli; M Manzetti; M Ialuna; M Traversari; A Paolucci; A Rinaldi; G D'Antonio; A Ruffilli
Journal:  Musculoskelet Surg       Date:  2022-08-09

6.  A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine.

Authors:  Yong Hu; Zhen-Shan Yuan; William Ryan Spiker; Wei-Xin Dong; Xiao-Yang Sun; Jian-Bing Yuan; Jiao Zhang; Bingke Zhu
Journal:  Eur Spine J       Date:  2016-03-28       Impact factor: 3.134

7.  CLINICAL APPLICATION OF A DRILL GUIDE TEMPLATE FOR PEDICLE SCREW PLACEMENT IN SEVERE SCOLIOSIS.

Authors:  Xin Li; Yaoshen Zhang; Qiang Zhang; Changsong Zhao; Kun Liu
Journal:  Acta Ortop Bras       Date:  2017 Mar-Apr       Impact factor: 0.513

8.  Clinical Use of 3D Printing Guide Plate in Posterior Lumbar Pedicle Screw Fixation.

Authors:  Hongliang Chen; Dongying Wu; Huilin Yang; Kaijin Guo
Journal:  Med Sci Monit       Date:  2015-12-18

9.  Accuracy Assessment of Using Rapid Prototyping Drill Templates for Atlantoaxial Screw Placement: A Cadaver Study.

Authors:  Shuai Guo; Teng Lu; Qiaolong Hu; Baohui Yang; Xijing He; Haopeng Li
Journal:  Biomed Res Int       Date:  2016-11-28       Impact factor: 3.411

10.  A semi-automatic computer-aided method for surgical template design.

Authors:  Xiaojun Chen; Lu Xu; Yue Yang; Jan Egger
Journal:  Sci Rep       Date:  2016-02-04       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.