Cervical screw placement using rapid prototyping drill templates for navigation: a literature review.

Teng Lu1, Chao Liu2, Jun Dong1, Meng Lu1, Haopeng Li1, Xijing He3.   

Abstract

PURPOSE: Due to the high screw malposition rate and the potential risk of neurovascular injury in cervical fixation surgeries, guided tools, mainly computer-assisted surgery navigation systems and rapid prototyping drill templates (RPDTs) have increasingly been developed to help surgeons improve screw placement accuracy. Although RPDTs have been used in cervical surgeries for almost 2 decades, no specific review has been performed detailing the state of this technique. Thus, in the current review, we fully discuss the status of applying RPDTs in cervical surgeries.
METHODS: Studies that tested the accuracy and reliability of RPDTs in guiding cervical screw placements were included in this review. The fabrication workflow and usage of RPDTs, the accuracy and reliability of using RPDTs for screw and plate placement, the advantages and disadvantages of RPDTs and their prospects for future applications as a part of cervical fixation instrumentation are discussed.
RESULTS: As the design of RPDTs becomes more rational, the accuracy and reliability of these devices have significantly improved in cervical fixation surgeries. Moreover, RPDTs decrease the intraoperative radiation exposure for surgeons and patients relative to conventional methods. However, some disadvantages also exist. The fabrication of RPDTs is time-consuming, and the time required to learn the related software is long.
CONCLUSION: We believe that because of their merits, the RPDT technique is worth promoting for use in cervical surgeries. However, the time-consuming fabrication workflow and the long period required to learn the related software might limit its widespread use. In the future, the workflow should be simplified to reduce the extra workload for surgeons. Moreover, more clinical studies with high-level evidence are still needed to further test its accuracy and feasibility.

Entities:  

Keywords:  Cervical screw; Computer-assisted; Drill template; Rapid prototyping; Screw placement accuracy

Mesh:

Year:  2016        PMID: 27160327     DOI: 10.1007/s11548-016-1414-3

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  54 in total

1.  Posterior C2 instrumentation: accuracy and complications associated with four techniques.

Authors:  Richard J Bransford; Anthony J Russo; Mark Freeborn; Quynh T Nguyen; Michael J Lee; Jens R Chapman; Carlo Bellabarba
Journal:  Spine (Phila Pa 1976)       Date:  2011-06-15       Impact factor: 3.468

2.  Biomodeling as an aid to spinal instrumentation.

Authors:  Paul S D'Urso; Owen D Williamson; Robert G Thompson
Journal:  Spine (Phila Pa 1976)       Date:  2005-12-15       Impact factor: 3.468

3.  Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement.

Authors:  Sheng Lu; Yong Q Xu; Guo P Chen; Yuan Z Zhang; Di Lu; Yu B Chen; Ji H Shi; Xing M Xu
Journal:  Comput Aided Surg       Date:  2011-08-12

4.  [Assessment of the surgeon radiation exposure during a minimally invasive TLIF: Comparison between fluoroscopy and O-arm system].

Authors:  M Grelat; F Zairi; M Quidet; P Marinho; M Allaoui; R Assaker
Journal:  Neurochirurgie       Date:  2015-06-10       Impact factor: 1.553

5.  Accuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws.

Authors:  Andrew G Patton; Randal P Morris; Yong-Fang Kuo; Ronald W Lindsey
Journal:  Spine (Phila Pa 1976)       Date:  2015-04-01       Impact factor: 3.468

6.  Computed tomography-guided C2 pedicle screw placement for treatment of unstable hangman fractures.

Authors:  Pankaj Kumar Singh; Kanwaljeet Garg; Duttaraj Sawarkar; Deepak Agarwal; Guru Dutta Satyarthee; Deepak Gupta; Sumit Sinha; Shashank Sarad Kale; Bhawani Shankar Sharma
Journal:  Spine (Phila Pa 1976)       Date:  2014-08-15       Impact factor: 3.468

7.  Spinal pedicle fixation. Confirmation of an image-based technique for screw placement.

Authors:  J C Steinmann; H N Herkowitz; H el-Kommos; D P Wesolowski
Journal:  Spine (Phila Pa 1976)       Date:  1993-10-01       Impact factor: 3.468

8.  Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study.

Authors:  Yong Hu; Zhen-shan Yuan; William Ryan Spiker; Todd J Albert; Wei-xin Dong; Hui Xie; Jian-bing Yuan; Cheng-tao Wang
Journal:  Eur Spine J       Date:  2013-09-05       Impact factor: 3.134

9.  A novel computer-assisted drill guide template for placement of C2 laminar screws.

Authors:  Sheng Lu; Yong Q Xu; Yuan Z Zhang; Le Xie; Hai Guo; Dong P Li
Journal:  Eur Spine J       Date:  2009-06-11       Impact factor: 3.134

10.  Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis.

Authors:  C A Dickman; V K Sonntag
Journal:  Neurosurgery       Date:  1998-08       Impact factor: 4.654

View more
  7 in total

Review 1.  Systematic review of 3D printing in spinal surgery: the current state of play.

Authors:  Ben Wilcox; Ralph J Mobbs; Ai-Min Wu; Kevin Phan
Journal:  J Spine Surg       Date:  2017-09

Review 2.  3D-printed navigation template in cervical spine fusion: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Ali Azimi; Ali Montazeri
Journal:  Eur Spine J       Date:  2020-09-16       Impact factor: 3.134

3.  Accuracy Assessment of Using Rapid Prototyping Drill Templates for Atlantoaxial Screw Placement: A Cadaver Study.

Authors:  Shuai Guo; Teng Lu; Qiaolong Hu; Baohui Yang; Xijing He; Haopeng Li
Journal:  Biomed Res Int       Date:  2016-11-28       Impact factor: 3.411

Review 4.  The Subaxial Cervical Pedicle Screw for Cervical Spine Diseases: The Review of Technical Developments and Complication Avoidance.

Authors:  Yoon Gyo Jung; Sang Ku Jung; Byung Jou Lee; Subum Lee; Seong Kyun Jeong; Myeongjong Kim; Jin Hoon Park
Journal:  Neurol Med Chir (Tokyo)       Date:  2020-04-15       Impact factor: 1.742

5.  Design and manufacturing of a patient-specific nasal implant for congenital arhinia: Case report.

Authors:  Alessandro Borghi; Federica Ruggiero; Maik Tenhagen; Silvia Schievano; Allan Ponniah; David Dunaway; Justine O'Hara; Juling Ong; Jonathan A Britto
Journal:  JPRAS Open       Date:  2019-06-12

6.  A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation.

Authors:  Ye Tian; Jianan Zhang; Tuanjiang Liu; Shi Tang; Hao Chen; Keyuan Ding; Dingjun Hao
Journal:  Med Sci Monit       Date:  2019-12-26

7.  Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis.

Authors:  Chengqiang Yu; Yufu Ou; Chengxin Xie; Yu Zhang; Jianxun Wei; Xiaoping Mu
Journal:  J Orthop Surg Res       Date:  2020-01-03       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.