Literature DB >> 16528192

Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws.

Samir B Lapsiwala1, Paul A Anderson, Ashish Oza, Daniel K Resnick.   

Abstract

OBJECTIVE: We performed a biomechanical comparison of several C1 to C2 fixation techniques including crossed laminar (intralaminar) screw fixation, anterior C1 to C2 transarticular screw fixation, C1 to 2 pedicle screw fixation, and posterior C1 to C2 transarticular screw fixation.
METHODS: Eight cadaveric cervical spines were tested intact and after dens fracture. Four different C1 to C2 screw fixation techniques were tested. Posterior transarticular and pedicle screw constructs were tested twice, once with supplemental sublaminar cables and once without cables. The specimens were tested in three modes of loading: flexion-extension, lateral bending, and axial rotation. All tests were performed in load and torque control. Pure bending moments of 2 nm were applied in flexion-extension and lateral bending, whereas a 1 nm moment was applied in axial rotation. Linear displacements were recorded from extensometers rigidly affixed to the C1 and C2 vertebrae. Linear displacements were reduced to angular displacements using trigonometry.
RESULTS: Adding cable fixation results in a stiffer construct for posterior transarticular screws. The addition of cables did not affect the stiffness of C1 to C2 pedicle screw constructs. There were no significant differences in stiffness between anterior and posterior transarticular screw techniques, unless cable fixation was added to the posterior construct. All three posterior screw constructs with supplemental cable fixation provide equal stiffness with regard to flexion-extension and axial rotation. C1 lateral mass-C2 intralaminar screw fixation restored resistance to lateral bending but not to the same degree as the other screw fixation techniques.
CONCLUSION: All four screw fixation techniques limit motion at the C1 to 2 articulation. The addition of cable fixation improves resistance to flexion and extension for posterior transarticular screw fixation.

Entities:  

Mesh:

Year:  2006        PMID: 16528192     DOI: 10.1227/01.NEU.0000197222.05299.31

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  52 in total

1.  Clinical application of C2 laminar screw technique.

Authors:  Weihu Ma; Leling Feng; Rongming Xu; Xiaochen Liu; Alan H Lee; Shaohua Sun; Liujun Zhao; Yong Hu; Guanyi Liu
Journal:  Eur Spine J       Date:  2010-06-05       Impact factor: 3.134

2.  Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance.

Authors:  Eric W Nottmeier; Andrew B Foy
Journal:  Eur Spine J       Date:  2007-11-22       Impact factor: 3.134

3.  Targeting a safe entry point for c2 pedicle screw fixation in patients with atlantoaxial instability.

Authors:  Hyoung-Joon Chun; Koang Hum Bak
Journal:  J Korean Neurosurg Soc       Date:  2011-06-30

4.  Morphometric trajectory analysis for the C2 crossing laminar screw technique.

Authors:  Bin Yue; Dai-Soon Kwak; Moon-Kyu Kim; Seong-Oh Kwon; Seung-Ho Han
Journal:  Eur Spine J       Date:  2010-02-21       Impact factor: 3.134

5.  C1-2 transarticular screws combined with C1 laminar hooks fixation: a modified posterior atlantoaxial fixation technique and outcome in 72 patients.

Authors:  Bin Ni; Xiang Guo; Ning Xie; Songkai Li; Fengjing Zhou; Feng Zhang; Qi Liu
Journal:  Eur Spine J       Date:  2012-08-21       Impact factor: 3.134

6.  Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2-3 fusion patients?

Authors:  Shenglin Wang; Chao Wang; Peter G Passias; Ming Yan; Haitao Zhou
Journal:  Eur Spine J       Date:  2010-05-04       Impact factor: 3.134

7.  Anterior and posterior fixation for delayed treatment of posterior atlantoaxial dislocation without fracture.

Authors:  Hai Ming Yu; Karan Malhotra; Joseph S Butler; Shi Qiang Wu
Journal:  BMJ Case Rep       Date:  2015-10-29

8.  A novel computer-assisted drill guide template for placement of C2 laminar screws.

Authors:  Sheng Lu; Yong Q Xu; Yuan Z Zhang; Le Xie; Hai Guo; Dong P Li
Journal:  Eur Spine J       Date:  2009-06-11       Impact factor: 3.134

Review 9.  Posterior atlantoaxial dislocation complicating odontoid fracture without neurologic deficit: a case report and review of the literature.

Authors:  Hao Meng; Yuan Gao; Mo Li; Zhuojing Luo; Junjie Du
Journal:  Skeletal Radiol       Date:  2014-01-29       Impact factor: 2.199

10.  Treatment of pediatric atlantoaxial instability with traditional and modified Goel-Harms fusion constructs.

Authors:  Gregory G Heuer; Douglas A Hardesty; Deb A Bhowmick; Robert Bailey; Suresh N Magge; Phillip B Storm
Journal:  Eur Spine J       Date:  2009-04-09       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.