Literature DB >> 11426150

Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2.

J Goffin1, K Van Brussel, K Martens, J Vander Sloten, R Van Audekercke, M H Smet.   

Abstract

STUDY
DESIGN: Cadaver and preliminary clinical study.
OBJECTIVES: To enhance the precision of screw positions for posterior transarticular fixations according to Magerl at C1-C2. SUMMARY OF BACKGROUND DATA: The vertebral arteries are at risk during the Magerl operation and may be damaged in up to 4.1% of cases. Even intraoperative navigation, as often used nowadays, does not provide optimal screw positioning in all patients.
METHODS: According to the three-dimensional CT data obtained for every individual cadaver or patient, a template was designed for the posterior course of C2: the template contains a drill guide allowing navigated screw positioning inside the left and right isthmus of C2. For a first series of five cadavers a template with clamps connecting only to the lamina of C2, excluding the spinous process from the interface, was carried out. For a second series of three cadavers the template was connected not only to the lamina but also to the spinous process of C2. Both cadaver series were performed without any fluoroscopic control at surgery. Eventually the technology was applied in two clinical cases.
RESULTS: The rotational stability of the template toward the lamina C2 was insufficient in the first series, but for the second series both the entry points and screw trajectories were very satisfactory.
CONCLUSIONS: Although the actual experience is limited, the idea of using a template with drill guide might simplify and shorten the surgical act and at the same time enhance the accuracy of C1-C2 transarticular screw positioning.

Entities:  

Mesh:

Year:  2001        PMID: 11426150     DOI: 10.1097/00007632-200106150-00017

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  26 in total

1.  Applications of three-dimensional printing technology in the cardiovascular field.

Authors:  Di Shi; Kai Liu; Xin Zhang; Hang Liao; Xiaoping Chen
Journal:  Intern Emerg Med       Date:  2015-07-29       Impact factor: 3.397

Review 2.  [Instability of the upper cervical spine due to rheumatism].

Authors:  C E Heyde; U Weber; R Kayser
Journal:  Orthopade       Date:  2006-03       Impact factor: 1.087

3.  Transarticular screw fixation for osteoarthritis of the atlanto axial segment.

Authors:  Dieter Grob; Friedrich H Bremerich; Jiri Dvorak; Anne F Mannion
Journal:  Eur Spine J       Date:  2005-06-21       Impact factor: 3.134

4.  Will 3D printing take away surgical planning from doctors?

Authors:  Lalit Maini; Raju Vaishya; Hitesh Lal
Journal:  J Clin Orthop Trauma       Date:  2018-09-06

5.  Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area.

Authors:  Mitsuru Takemoto; Shunsuke Fujibayashi; Eigo Ota; Bungo Otsuki; Hiroaki Kimura; Takeshi Sakamoto; Toshiyuki Kawai; Tohru Futami; Kiyoyuki Sasaki; Tomiharu Matsushita; Takashi Nakamura; Masashi Neo; Shuich Matsuda
Journal:  Eur Spine J       Date:  2015-03-29       Impact factor: 3.134

Review 6.  Cervical screw placement using rapid prototyping drill templates for navigation: a literature review.

Authors:  Teng Lu; Chao Liu; Jun Dong; Meng Lu; Haopeng Li; Xijing He
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-09       Impact factor: 2.924

7.  Accuracy of thoracic pedicle screw placement in adolescent patients with severe spinal deformities: a retrospective study comparing drill guide template with free-hand technique.

Authors:  Yue Pan; G H Lü; Lei Kuang; Bing Wang
Journal:  Eur Spine J       Date:  2017-12-12       Impact factor: 3.134

8.  Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study.

Authors:  Yong Hu; Zhen-shan Yuan; William Ryan Spiker; Todd J Albert; Wei-xin Dong; Hui Xie; Jian-bing Yuan; Cheng-tao Wang
Journal:  Eur Spine J       Date:  2013-09-05       Impact factor: 3.134

9.  A novel computer-assisted drill guide template for placement of C2 laminar screws.

Authors:  Sheng Lu; Yong Q Xu; Yuan Z Zhang; Le Xie; Hai Guo; Dong P Li
Journal:  Eur Spine J       Date:  2009-06-11       Impact factor: 3.134

10.  Computer-aided design and custom-made guide in corrective osteotomy for complex femoral deformity.

Authors:  Wei Chai; Meng Xu; Guo-Qiang Zhang; Li-Hai Zhang; Wen-Long Gou; Ming Ni; Ji-Ying Chen
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-06-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.