Literature DB >> 23997465

Evaluation of effect of tray space on the accuracy of condensation silicone, addition silicone and polyether impression materials: an in vitro study.

Varun Kumar1, Himanshu Aeran.   

Abstract

Optimal thickness of impression materials in the custom tray in order to get the most accurate impression. To investigate the effect of different tray spacer thickness on the accuracy and the dimensional stability of impressions made from monophasic condensation silicone, addition silicone and polyether impression materials. Three different types of elastomeric monophasic impression materials were used for making the impression of a master die with tray having tray spacer thickness of 2, 4 and 6 mm. Each type of impression was poured in die stone after 1 h. Each cast was analyzed by a travelling microscope and compared with the master die. The data was tabulated and subjected to statistical evaluation. The results of the study indicated that the impressions made from 2 to 4 mm spaced trays produced more accurate stone casts when compared to 6 mm spaced tray. No statistical significant differences were observed between the accuracy and dimensional stability of the three materials tested. Minimum changes were observed when the cast was poured after 1 h and the tray space was 2 mm for all the materials tested. It is therefore advisable not to exceed tray space of 2 mm.

Entities:  

Keywords:  Addition silicone; Condensation silicone; Polyether

Year:  2012        PMID: 23997465      PMCID: PMC3416934          DOI: 10.1007/s13191-012-0124-y

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  11 in total

1.  Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy.

Authors:  Mary E Brosky; Igor J Pesun; Philip D Lowder; Ralph Delong; James S Hodges
Journal:  J Prosthet Dent       Date:  2002-02       Impact factor: 3.426

2.  A comparison of elastic impression materials.

Authors:  J A Stackhouse
Journal:  J Prosthet Dent       Date:  1975-09       Impact factor: 3.426

3.  The effect of tray selection on the accuracy of elastomeric impression materials.

Authors:  G E Gordon; G H Johnson; D G Drennon
Journal:  J Prosthet Dent       Date:  1990-01       Impact factor: 3.426

4.  Accuracy and dimensional stability of elastomeric impression materials.

Authors:  W B Eames; S W Wallace; N B Suway; L B Rogers
Journal:  J Prosthet Dent       Date:  1979-08       Impact factor: 3.426

5.  Clinically oriented evaluation of the accuracy of commonly used impression materials.

Authors:  A H Tjan; S B Whang; A H Tjan; R Sarkissian
Journal:  J Prosthet Dent       Date:  1986-07       Impact factor: 3.426

6.  Elastomeric impression materials: effect of bulk on accuracy.

Authors:  W B Eames; J C Sieweke; S W Wallace; L B Rogers
Journal:  J Prosthet Dent       Date:  1979-03       Impact factor: 3.426

7.  Linear dimensional changes in addition curing silicone impression materials.

Authors:  C F Marcinak; R A Draughn
Journal:  J Prosthet Dent       Date:  1982-04       Impact factor: 3.426

8.  Time-dependent accuracy of elastomer impression materials. Part II: Polyether, polysulfides, and polyvinylsiloxane.

Authors:  A M Lacy; H Fukui; T Bellman; M D Jendresen
Journal:  J Prosthet Dent       Date:  1981-03       Impact factor: 3.426

9.  Effect of tray space on the accuracy of monophasic polyvinylsiloxane impressions.

Authors:  A H Tjan; H Nemetz; L T Nguyen; R Contino
Journal:  J Prosthet Dent       Date:  1992-07       Impact factor: 3.426

10.  Accuracy of addition silicones as a function of technique.

Authors:  G H Johnson; R G Craig
Journal:  J Prosthet Dent       Date:  1986-02       Impact factor: 3.426

View more
  3 in total

1.  Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods.

Authors:  Satheesh B Haralur; Majed Saad Toman; Abdullah Ali Al-Shahrani; Abdullah Ali Al-Qarni
Journal:  Int J Dent       Date:  2016-12-14

2.  Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique.

Authors:  Marie-Hélène Pastoret; Gabriel Krastl; Julia Bühler; Roland Weiger; Nicola Ursula Zitzmann
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

3.  Effect of multiple pouring on the accuracy of casts made using 3D-printed custom trays with different spacer thicknesses: A research study.

Authors:  Sara Tavakolizadeh; Mohammad Javad Razaghi; Pedram Pakravan; Majid Sedaghat Monfared; Elaheh Beyabanaki; Rahab Ghoveizi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2020
  3 in total