Literature DB >> 11854678

Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy.

Mary E Brosky1, Igor J Pesun, Philip D Lowder, Ralph Delong, James S Hodges.   

Abstract

UNLABELLED: STATEMENT OF PROBLEM; Several studies have attempted to determine the ideal combination of dental materials and laboratory techniques to produce the most accurate dental cast. Most have made use of 2-dimensional manual measuring devices, which neglect to account for the dimensional changes that exist along a 3-dimensional surface.
PURPOSE: The purpose of this study was to determine the effect of impression tray selection and cast formation techniques on the dimensional change of a dental cast with the use of new, 3-dimensional optical digitizing technology.
MATERIAL AND METHODS: Multiple impressions of a machined steel die that resembled a dental arch were made with custom and stock impression trays and vinyl polysiloxane impression material. The impressions were poured in type V artificial dental stone and allowed to set with the tray inverted or noninverted. The steel master die and stone casts were digitized with the Steinbichler Comet 100 Optical Digitizer, which was developed at the Minnesota Dental Research Center for Biomaterials and Biomechanics. Three-dimensional images of the stone casts were aligned to the 3-dimensional image of the master die and analyzed with AnSur-NT software. Multiple measurements of the master die and stone casts were analyzed to determine the accuracy of the 3-dimensional technology and of the impression and cast fabrication techniques. Planar distances between the center of each crown preparation were measured, as were crown heights. Data were analyzed with analysis of variance (P<.05), and root mean square error values were determined.
RESULTS: Casts were compared with a total of 45 significance tests, of which only 4 yielded P<.05. There was no pattern to these results, which suggests that they were false-positive findings.
CONCLUSION: Results obtained with the use of new optical digitizing technology indicated that neither impression tray type nor cast formation technique affected the accuracy of final casts.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11854678     DOI: 10.1067/mpr.2002.121240

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  15 in total

1.  In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

Authors:  Andreas Ender; Moritz Zimmermann; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-11-07       Impact factor: 3.573

2.  Evaluation of effect of tray space on the accuracy of condensation silicone, addition silicone and polyether impression materials: an in vitro study.

Authors:  Varun Kumar; Himanshu Aeran
Journal:  J Indian Prosthodont Soc       Date:  2012-06-04

Review 3.  Digitization and its futuristic approach in prosthodontics.

Authors:  Ritika Bhambhani; Jayanta Bhattacharya; Saibal Kr Sen
Journal:  J Indian Prosthodont Soc       Date:  2012-10-07

4.  A comparative evaluation of wear of enamel caused by ceramics with different fusion temperatures.

Authors:  Meenakshi Khandelwal; Deshraj Jain
Journal:  J Indian Prosthodont Soc       Date:  2012-11-01

5.  Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

Authors:  Heike Rudolph; Sebastian Quaas; Manuela Haim; Jörg Preißler; Michael H Walter; Rainer Koch; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2012-08-31       Impact factor: 3.573

6.  Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique.

Authors:  Lee Wei May; Jacob John; Lim Ghee Seong; Zubaidah Zanul Abidin; Norliza Ibrahim; Mahmoud Danaee; Noorhayati Raja Mohd
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

7.  Effect of pouring time and storage temperature on dimensional stability of casts made from irreversible hydrocolloid.

Authors:  M Farzin; H Panahandeh
Journal:  J Dent (Tehran)       Date:  2010-09-30

8.  Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

Authors:  Jin-Hun Jeon; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

9.  Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

Authors:  Emir Yuzbasioglu; Hanefi Kurt; Rana Turunc; Halenur Bilir
Journal:  BMC Oral Health       Date:  2014-01-30       Impact factor: 2.757

10.  Changes in views on digital intraoral scanners among dental hygienists after training in digital impression taking.

Authors:  Hye-Ran Park; Ji-Man Park; Youn-Sic Chun; Kkot-Nim Lee; Minji Kim
Journal:  BMC Oral Health       Date:  2015-11-27       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.