Literature DB >> 6951042

Linear dimensional changes in addition curing silicone impression materials.

C F Marcinak, R A Draughn.   

Abstract

Five vinyl polysiloxane addition curing impression materials were evaluated on the basis of linear dimensional change occurring as a function of time between making an impression and pouring the die. The dies were measured and compared to a master model to determine the linear change in the impression material. One material produced an overall larger die, but the greatest increase in size deviated from the master model by only 0.1%. Permagum putty-wash material consistently produced undersized dies, with the greatest change being 0.3%. Three materials randomly produced smaller or larger dies, differing from the master model by only 0.08% for the smallest die to 0.07% for the largest. No consistent pattern of increase or decrease in die size occurred with time. Dies produced at 168 hours were as accurate as those produced at 10 minutes.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6951042     DOI: 10.1016/s0022-3913(82)80092-9

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Evaluation of effect of tray space on the accuracy of condensation silicone, addition silicone and polyether impression materials: an in vitro study.

Authors:  Varun Kumar; Himanshu Aeran
Journal:  J Indian Prosthodont Soc       Date:  2012-06-04

2.  Comparison of dimensional accuracy of elastomeric impression materials using 3D laser scanner.

Authors:  Sushil Kar; Arvind Tripathi; Juhi Singh; J Ramkumar
Journal:  Med J Armed Forces India       Date:  2021-07-30

3.  A Comparison of Dimensional Accuracy of Addition Silicone of Different Consistencies with Two Different Spacer Designs - In-vitro Study.

Authors:  Suprabha Rathee; B Eswaran; Ma Eswaran; R Prabhu; Kr Geetha; Gp Krishna
Journal:  J Clin Diagn Res       Date:  2014-07-20

4.  Effect of multiple pouring on the accuracy of casts made using 3D-printed custom trays with different spacer thicknesses: A research study.

Authors:  Sara Tavakolizadeh; Mohammad Javad Razaghi; Pedram Pakravan; Majid Sedaghat Monfared; Elaheh Beyabanaki; Rahab Ghoveizi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2020

5.  Comparative evaluation of elastic recovery of three different elastomeric impression materials on chemical disinfection and autoclaving: An in vitro study.

Authors:  Garima Gothwal; Sudhir Meena; U Narendra Padiyar; Hemant Kumar Sharma; Pragati Kaurani; Devendra Pal Singh
Journal:  J Indian Prosthodont Soc       Date:  2019-10-10

6.  Accuracy of different putty-wash impression techniques with various spacer thickness.

Authors:  Anshul Chugh; Aman Arora; Vijay Pratap Singh
Journal:  Int J Clin Pediatr Dent       Date:  2012-02-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.