Literature DB >> 23993343

In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty.

William Barrett1, Daniel Hoeffel2, David Dalury3, J Bohannon Mason4, Jeff Murphy5, Sam Himden5.   

Abstract

Patient specific instrumentation (PSI) was developed to increase total knee arthroplasty (TKA) accuracy and efficiency. The study purpose was to compare immediate post-operative mechanical alignment, achieved using PSI, with conventional and computer assisted surgery (CAS) instruments in high volume TKA practices. This prospective, multicenter, non-randomized study accrued 66 TKA patients using PSI. A computed tomography (CT) based algorithm was used to develop the surgical plan. Sixty-two percent were females, 99% were diagnosed with osteoarthritis, average age at surgery was 66 years, and 33 was the average body mass index. A historical control group was utilized that underwent TKA using conventional instruments (n=86) or CAS (n=81), by the same set of surgeons. Postoperative mechanical alignment was comparable across the groups. Operative time mean and variance were significant.
© 2013.

Entities:  

Keywords:  customized cutting blocks; customized patient instrumentation patient specific; instrumentation; mechanical alignment; surgical time; total knee arthroplasty

Mesh:

Year:  2013        PMID: 23993343     DOI: 10.1016/j.arth.2013.06.029

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  25 in total

Review 1.  Patient specific instrumentation in total knee arthroplasty: a state of the art.

Authors:  Lorenzo Mattei; Pietro Pellegrino; Michel Calò; Alessandro Bistolfi; Filippo Castoldi
Journal:  Ann Transl Med       Date:  2016-04

2.  Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial.

Authors:  Tilman Pfitzner; Matthew P Abdel; Philipp von Roth; Carsten Perka; Hagen Hommel
Journal:  Clin Orthop Relat Res       Date:  2014-07-15       Impact factor: 4.176

3.  Navigation in TKA surgery - Evolutionary technique or blind alley?

Authors:  Heiko Graichen
Journal:  J Orthop       Date:  2015-03-06

4.  How are we addressing ligament balance in TKA? A literature review of revision etiology and technological advancement.

Authors:  Tyler Smith; Leah Elson; Christopher Anderson; William Leone
Journal:  J Clin Orthop Trauma       Date:  2016-08-03

5.  Does implant design and surgical technique improve the clinical outcome in total knee arthroplasty?

Authors:  Roland Becker; Michael T Hirschmann; Jon Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08       Impact factor: 4.342

Review 6.  Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis.

Authors:  Etienne Cavaignac; Regis Pailhé; Gregoire Laumond; Jérôme Murgier; Nicolas Reina; Jean Michel Laffosse; Emilie Bérard; Philippe Chiron
Journal:  Int Orthop       Date:  2014-10-10       Impact factor: 3.075

7.  No benefit of patient-specific instrumentation in TKA on functional and gait outcomes: a randomized clinical trial.

Authors:  Matthew P Abdel; Sébastien Parratte; Guillaume Blanc; Matthieu Ollivier; Vincent Pomero; Elke Viehweger; Jean-Noël A Argenson
Journal:  Clin Orthop Relat Res       Date:  2014-03-07       Impact factor: 4.176

8.  Medical 3D Printing Cost-Savings in Orthopedic and Maxillofacial Surgery: Cost Analysis of Operating Room Time Saved with 3D Printed Anatomic Models and Surgical Guides.

Authors:  David H Ballard; Patrick Mills; Richard Duszak; Jeffery A Weisman; Frank J Rybicki; Pamela K Woodard
Journal:  Acad Radiol       Date:  2019-09-18       Impact factor: 3.173

9.  Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study.

Authors:  Andrzej Kotela; Ireneusz Kotela
Journal:  Int Orthop       Date:  2014-06-28       Impact factor: 3.075

10.  Verification of in vivo accuracy of Trumatch™ patient-specific instrumentation in total knee replacement using pin-less computer navigation.

Authors:  Nikolai Briffa; Mohamed A Imam; Ravi Mallina; Ashraf Abdelkafy; Ajeya Adhikari
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-07