Literature DB >> 27604905

Verification of in vivo accuracy of Trumatch™ patient-specific instrumentation in total knee replacement using pin-less computer navigation.

Nikolai Briffa1, Mohamed A Imam1,2, Ravi Mallina1, Ashraf Abdelkafy3, Ajeya Adhikari1.   

Abstract

PURPOSE: Accurate component alignment in total knee replacement (TKR) is one of the important factors in determining long-term survivorship. This has been achieved by conventional jigs, computer-assisted technology (CAS) and more recently patient-specific instrumentation (PSI). The purpose of the current study was to investigate the in vivo accuracy of Trumatch™ PSI using validated pin-less computer navigation system.
METHOD: Twenty consecutive selected patients that fulfilled our inclusion/exclusion criteria underwent TKR using PSI. Coronal alignment, posterior slope, resection thickness and femoral sagittal alignment were recorded using pin-less navigation. The position of the actual cutting block was appropriately adjusted prior to proceeding to definitive resections.
RESULTS: The coronal alignment using PSI without the assistance of navigation would have resulted in 14 (70 %) within ±3°, 11 (55 %) within ±2° and 6 (30 %) outside acceptable alignment. Thirty-five percentage of proposed femur sagittal alignment and 55 % of posterior tibial slope were achieved within ±3°. Components size was accurately predicted in 95 % of femurs and 90 % of tibia.
CONCLUSION: The purported advantages in restoring alignments using Trumatch™ PSI alone over standard equipment are debatable. However, it predicts sizing well, and femoral coronal alignment is reasonable. Combining Trumatch™ PSI with CAS will allow in vivo verification and necessary corrections. LEVEL OF EVIDENCE: IV.

Entities:  

Keywords:  Computer navigation; Patient-specific instrumentation; Total knee arthroplasty; Total knee replacement; Trumatch™

Mesh:

Year:  2016        PMID: 27604905     DOI: 10.1007/s00590-016-1849-9

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  33 in total

1.  Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; C Perlick; J Grifka
Journal:  Int Orthop       Date:  2004-01-17       Impact factor: 3.075

2.  Small differences between anatomical and mechanical sagittal femur axes: a radiological and navigated study of 50 patients.

Authors:  Jean-Yves Jenny; Bruno Barbe
Journal:  Arch Orthop Trauma Surg       Date:  2012-03-21       Impact factor: 3.067

3.  Kinematically versus mechanically aligned total knee arthroplasty.

Authors:  H Gene Dossett; George J Swartz; Nicolette A Estrada; George W LeFevre; Bertram G Kwasman
Journal:  Orthopedics       Date:  2012-02-17       Impact factor: 1.390

4.  Differences between sagittal femoral mechanical and distal reference axes should be considered in navigated TKA.

Authors:  Byung June Chung; Yeon Gwi Kang; Chong Bum Chang; Sung Ju Kim; Tae Kyun Kim
Journal:  Clin Orthop Relat Res       Date:  2009-02-26       Impact factor: 4.176

5.  The landmarks of centers of the distal femur and the proximal tibia in sagittal plane for application in computer assisted total knee arthroplasty.

Authors:  Naraphong Hangsaphuk; Aree Tanavalee
Journal:  J Med Assoc Thai       Date:  2009-12

6.  MRI is more accurate than CT for patient-specific total knee arthroplasty.

Authors:  Benjamin M Frye; Amjad A Najim; Joanne B Adams; Keith R Berend; Adolph V Lombardi
Journal:  Knee       Date:  2015-03-23       Impact factor: 2.199

7.  Do patient-specific guides improve coronal alignment in total knee arthroplasty?

Authors:  Ryan M Nunley; Bradley S Ellison; Jinjun Zhu; Erin L Ruh; Stephen M Howell; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2011-12-20       Impact factor: 4.176

8.  Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA.

Authors:  Vincent Y Ng; Jeffrey H DeClaire; Keith R Berend; Bethany C Gulick; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

9.  The value of patient-matched instrumentation in total knee arthroplasty.

Authors:  John W Noble; Chris A Moore; Ning Liu
Journal:  J Arthroplasty       Date:  2011-09-09       Impact factor: 4.757

10.  Patient-specific cutting blocks: Of Unproven Value.

Authors:  G-C Lee
Journal:  Bone Joint J       Date:  2016-01       Impact factor: 5.082

View more
  2 in total

1.  Significant differences between manufacturer and surgeon in the accuracy of final component size prediction with CT-based patient-specific instrumentation for total knee arthroplasty.

Authors:  Davide Cucchi; Alessandra Menon; Riccardo Compagnoni; Paolo Ferrua; Chiara Fossati; Pietro Randelli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-16       Impact factor: 4.342

Review 2.  Computed tomography based 3D printed patient specific blocks for total knee replacement.

Authors:  Raju Vaishya; Vipul Vijay; Abhishek Vaish; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2018-07-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.