Literature DB >> 23974909

Determination of cardiac output with dynamic contrast-enhanced computed tomography.

Michael Pienn1, Gabor Kovacs, Maria Tscherner, Thorsten R Johnson, Peter Kullnig, Rudolf Stollberger, Andrea Olschewski, Horst Olschewski, Zoltán Bálint.   

Abstract

Cardiac output (CO) is an important diagnostic and prognostic factor in the haemodynamic evaluation of patients. The gold standard for CO measurement, thermodilution, requires an invasive right-heart catheterisation (RHC). In this pilot study we aimed to determine the accuracy of non-invasive CO determination from dynamic contrast-enhanced computed tomography (CT) compared to thermodilution. Patients who underwent diagnostic or follow-up RHC due to suspected or known pulmonary vascular disease at our department and required a thoracic CT between June 2011 and August 2012 were included. CO was determined from CT attenuation-time curves in the pulmonary artery and the ascending aorta using a dynamic contrast-enhanced CT sequence. CO determined in N = 18 patients by dynamic CT in the pulmonary artery was in very good agreement with thermodilution data (r = 0.84). Bland-Altman analysis showed a systematic overestimation of 0.7 ± 0.6 l/min compared to thermodilution. Data from the ascending aorta also showed a good correlation, but with a larger scattering of the values. The average effective dose for the dynamic investigation was 1.2 ± 0.7 mSv. CO determined with dynamic contrast-enhanced CT in the main pulmonary artery reliably predicts the values obtained by thermodilution during RHC. This non-invasive technique might provide an alternative for repeated invasive right-heart catheter investigations in the follow-up of pulmonary arterial hypertension patients.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23974909     DOI: 10.1007/s10554-013-0279-6

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  32 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  A formula to estimate the approximate surface area if height and weight be known. 1916.

Authors:  D Du Bois; E F Du Bois
Journal:  Nutrition       Date:  1989 Sep-Oct       Impact factor: 4.008

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Dynamic computed tomography to determine cardiac output in patients with left ventricular assist devices.

Authors:  Subha V Raman; Tam Tran; Orlando P Simonetti; Benjamin Sun
Journal:  J Thorac Cardiovasc Surg       Date:  2009-02-07       Impact factor: 5.209

5.  Accuracy of Doppler echocardiography in the hemodynamic assessment of pulmonary hypertension.

Authors:  Micah R Fisher; Paul R Forfia; Elzbieta Chamera; Traci Housten-Harris; Hunter C Champion; Reda E Girgis; Mary C Corretti; Paul M Hassoun
Journal:  Am J Respir Crit Care Med       Date:  2009-01-22       Impact factor: 21.405

6.  Noninvasive cardiac output: simultaneous comparison of two different methods with thermodilution.

Authors:  D H Wong; K K Tremper; E A Stemmer; D O'Connor; S Wilbur; J Zaccari; C Reeves; P Weidoff; R J Trujillo
Journal:  Anesthesiology       Date:  1990-05       Impact factor: 7.892

7.  CT effective dose per dose length product using ICRP 103 weighting factors.

Authors:  Walter Huda; Dennise Magill; Wenjun He
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

8.  Measurement of cardiac output by computed transmission tomography.

Authors:  R J Herfkens; L Axel; M J Lipton; S Napel; W Berninger; R Redington
Journal:  Invest Radiol       Date:  1982 Nov-Dec       Impact factor: 6.016

9.  Evaluation of right ventricular performance with a right ventricular ejection fraction thermodilution catheter and MRI in patients with pulmonary hypertension.

Authors:  M M Hoeper; J Tongers; A Leppert; S Baus; R Maier; J Lotz
Journal:  Chest       Date:  2001-08       Impact factor: 9.410

10.  Quantitation of cardiac output with velocity-encoded, phase-difference magnetic resonance imaging.

Authors:  W G Hundley; H F Li; L D Hillis; B M Meshack; R A Lange; J E Willard; C Landau; R M Peshock
Journal:  Am J Cardiol       Date:  1995-06-15       Impact factor: 2.778

View more
  4 in total

1.  Non-invasive determination of pulmonary hypertension with dynamic contrast-enhanced computed tomography: a pilot study.

Authors:  Michael Pienn; Gabor Kovacs; Maria Tscherner; Alexander Avian; Thorsten R Johnson; Peter Kullnig; Rudolf Stollberger; Andrea Olschewski; Horst Olschewski; Zoltán Bálint
Journal:  Eur Radiol       Date:  2013-12-06       Impact factor: 5.315

2.  Effect of Cardiac Phase on Cardiac Output Index Derived from Dynamic CT Myocardial Perfusion Imaging.

Authors:  Sergio C H Dempsey; Ting-Yim Lee; Abbas Samani; Aaron So
Journal:  Tomography       Date:  2022-04-14

3.  EXPRESS: Statement on imaging and pulmonary hypertension from the Pulmonary Vascular Research Institute (PVRI).

Authors:  David G Kiely; David Levin; Paul Hassoun; David D Ivy; Pei-Ni Jone; Jumaa Bwika; Steven M Kawut; Jim Lordan; Angela Lungu; Jeremy Mazurek; Shahin Moledina; Horst Olschewski; Andrew Peacock; Goverdhan Dutt Puri; Farbod Rahaghi; Michal Schafer; Mark Schiebler; Nicholas Screaton; Merryn Tawhai; Edwin Jr Van Beek; Anton Vonk-Noordegraaf; Rebecca R Vanderpool; John Wort; Lan Zhao; Jim Wild; Jens Vogel-Claussen; Andrew J Swift
Journal:  Pulm Circ       Date:  2019-03-18       Impact factor: 3.017

4.  Quantification of tortuosity and fractal dimension of the lung vessels in pulmonary hypertension patients.

Authors:  Michael Helmberger; Michael Pienn; Martin Urschler; Peter Kullnig; Rudolf Stollberger; Gabor Kovacs; Andrea Olschewski; Horst Olschewski; Zoltán Bálint
Journal:  PLoS One       Date:  2014-01-31       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.