Literature DB >> 11502650

Evaluation of right ventricular performance with a right ventricular ejection fraction thermodilution catheter and MRI in patients with pulmonary hypertension.

M M Hoeper1, J Tongers, A Leppert, S Baus, R Maier, J Lotz.   

Abstract

STUDY
OBJECTIVES: We sought to compare catheter studies using a right ventricular ejection fraction (REF) catheter together with echocardiography and MRI in patients with pulmonary hypertension. PATIENTS AND METHODS: We compared hemodynamic findings, echocardiography, and MRI studies in 16 patients with pulmonary hypertension. Six healthy volunteers served as control subjects for the MRI studies.
RESULTS: MRI imaging provided accurate assessment of cardiac output in all but two patients. As compared with MRI, the REF catheter constantly underestimated the REF and overestimated right ventricular volumes in patients with pulmonary hypertension. REF, end-systolic and end-diastolic right ventricular volumes, and right ventricular muscle mass, as determined by MRI, were almost identical in patients with preserved cardiac function and those with low-output failure. The only factor that was different in both groups was the severity of tricuspid regurgitation.
CONCLUSION: Right ventricular dimensions and muscle mass do not differ in patients with pulmonary hypertension who have low cardiac output and those who do not. According to our results, the major determinant of cardiac output in these patients appears to be the severity of tricuspid regurgitation. The REF catheter provides invalid data on right ventricular dimensions in patients with pulmonary hypertension.

Entities:  

Mesh:

Year:  2001        PMID: 11502650     DOI: 10.1378/chest.120.2.502

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  19 in total

1.  Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography.

Authors:  Tae Hoon Kim; Young Hoon Ryu; Jin Hur; Sang Jin Kim; Hyun Soo Kim; Byoung Wook Choi; Young Kim; Hyung Jung Kim
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

Review 2.  Surrogate end points in pulmonary arterial hypertension: assessing the response to therapy.

Authors:  Jennifer L Snow; Steven M Kawut
Journal:  Clin Chest Med       Date:  2007-03       Impact factor: 2.878

Review 3.  Imaging modalities for the diagnosis of pulmonary hypertension in systemic sclerosis.

Authors:  Theodoros Dimitroulas; Sophie Mavrogeni; George D Kitas
Journal:  Nat Rev Rheumatol       Date:  2012-02-07       Impact factor: 20.543

4.  What does the time constant of the pulmonary circulation tell us about the progression of right ventricular dysfunction in pulmonary arterial hypertension?

Authors:  A Bellofiore; Z Wang; N C Chesler
Journal:  Pulm Circ       Date:  2015-06       Impact factor: 3.017

Review 5.  The right ventricle in pulmonary arterial hypertension: disorders of metabolism, angiogenesis and adrenergic signaling in right ventricular failure.

Authors:  John J Ryan; Stephen L Archer
Journal:  Circ Res       Date:  2014-06-20       Impact factor: 17.367

6.  Is MRI the preferred method for evaluating right ventricular size and function in patients with congenital heart disease?: MRI is the preferred method for evaluating right ventricular size and function in patients with congenital heart disease.

Authors:  Tal Geva
Journal:  Circ Cardiovasc Imaging       Date:  2014-01       Impact factor: 7.792

7.  Pulmonary arterial hypertension in children: Diagnostic work-up and challenges.

Authors:  E B Rosenzweig; J A Feinstein; T Humpl; D D Ivy
Journal:  Prog Pediatr Cardiol       Date:  2009-12

8.  Determination of cardiac output with dynamic contrast-enhanced computed tomography.

Authors:  Michael Pienn; Gabor Kovacs; Maria Tscherner; Thorsten R Johnson; Peter Kullnig; Rudolf Stollberger; Andrea Olschewski; Horst Olschewski; Zoltán Bálint
Journal:  Int J Cardiovasc Imaging       Date:  2013-08-23       Impact factor: 2.357

9.  Perioperative intravascular fluid assessment and monitoring: a narrative review of established and emerging techniques.

Authors:  Sumit Singh; Ware G Kuschner; Geoffrey Lighthall
Journal:  Anesthesiol Res Pract       Date:  2011-07-12

10.  Is stroke volume variation a useful preload index in liver transplant recipients? A retrospective analysis.

Authors:  Sung-Hoon Kim; Gyu-Sam Hwang; Seon-Ok Kim; Young-Kug Kim
Journal:  Int J Med Sci       Date:  2013-04-18       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.