The outcome of the Ahmad Glaucoma Valve implantation for refractory glaucoma in Kuwait.

Adel M Aljazzaf1, Sidky M A Abdelmoaty, Abdelmutalib H Behbehani, Ahmad A Abdulmuez, Hadeel A Aljazzaf.   

Abstract

AIM: To assess the outcomes and incidence of postoperative complications of Ahmad Glaucoma Valve implant in eyes with complicated glaucoma performed in Kuwait.
METHOD: This is a retrospective study done at the Al-Bahar Eye Center in Kuwait. Charts of all patients who underwent Ahmad Glaucoma Valve implant at the Al-Bahar Ophthalmic Center in Kuwait between 2006 and 2009 were reviewed. Surgical success was defined as intraocular pressure less than 22 mmHg and greater than 5 mmHg without additional glaucoma surgery and without loss of light perception.
RESULTS: A total of 33 eyes from 30 patients with complicated glaucoma not responsive to conventional medical and non-implant surgical treatment received Ahmad Glaucoma Valve implant. The success rate was 79% (26 cases). 20/26 (77%) cases of them required antiglaucoma medications. The most common complication was encapsulated bleb (27%) and transient postoperative hypotony was found in 19% of the cases.
CONCLUSION: Ahmad Glaucoma Valve implant appears to be effective and relatively safe for complicated glaucoma in Kuwait. The success rate is comparable with those reported in other studies.

Entities:  

Keywords:  Ahmad Glaucoma Valve; Glaucoma; Hypotony

Year:  2012        PMID: 23964181      PMCID: PMC3729801          DOI: 10.1016/j.sjopt.2012.10.001

Source DB:  PubMed          Journal:  Saudi J Ophthalmol        ISSN: 1319-4534


  15 in total

1.  Clinical risk factors for failure in glaucoma tube surgery. A comparison of three tube designs.

Authors:  M J Lavin; W A Franks; R P Wormald; R A Hitchings
Journal:  Arch Ophthalmol       Date:  1992-04

2.  Outcome of White pump shunt surgery for neovascular glaucoma in Asians.

Authors:  E Chihara; H Kubota; T Takanashi; N Nao-i
Journal:  Ophthalmic Surg       Date:  1992-10

Review 3.  Glaucoma drainage devices; past, present, and future.

Authors:  K S Lim; B D Allan; A W Lloyd; A Muir; P T Khaw
Journal:  Br J Ophthalmol       Date:  1998-09       Impact factor: 4.638

4.  Nd: YAG laser for Ahmed tube shunt occlusion by the posterior capsule.

Authors:  Z Tessler; S Jluchoded; G Rosenthal
Journal:  Ophthalmic Surg Lasers       Date:  1997-01

5.  Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant.

Authors:  M C Huang; P A Netland; A L Coleman; S W Siegner; M R Moster; R A Hill
Journal:  Am J Ophthalmol       Date:  1999-01       Impact factor: 5.258

6.  The Ahmed valve in refractory pediatric glaucoma.

Authors:  J A Englert; S F Freedman; T A Cox
Journal:  Am J Ophthalmol       Date:  1999-01       Impact factor: 5.258

7.  Valve membrane adhesion as a cause of Ahmed glaucoma valve failure.

Authors:  R M Feldman; S M el-Harazi; G Villanueva
Journal:  J Glaucoma       Date:  1997-02       Impact factor: 2.503

8.  Initial clinical experience with the Ahmed Glaucoma Valve implant.

Authors:  A L Coleman; R Hill; M R Wilson; N Choplin; R Kotas-Neumann; M Tam; J Bacharach; W C Panek
Journal:  Am J Ophthalmol       Date:  1995-07       Impact factor: 5.258

9.  Clinical experience with the single-plate Molteno implant in complicated glaucomas.

Authors:  D S Minckler; D K Heuer; B Hasty; G Baerveldt; R C Cutting; W E Barlow
Journal:  Ophthalmology       Date:  1988-09       Impact factor: 12.079

10.  Clinical experience with the Baerveldt glaucoma drainage implant.

Authors:  S W Siegner; P A Netland; R C Urban; A S Williams; D W Richards; M A Latina; J D Brandt
Journal:  Ophthalmology       Date:  1995-09       Impact factor: 12.079

View more
  1 in total

1.  Long-term results of Ahmed glaucoma valve implantation in Egyptian population.

Authors:  Eman Elhefney; Tharwat Mokbel; Waleed Abou Samra; Hanem Kishk; Tarek Mohsen; Amr El-Kannishy
Journal:  Int J Ophthalmol       Date:  2018-03-18       Impact factor: 1.779

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.