Literature DB >> 3211496

Clinical experience with the single-plate Molteno implant in complicated glaucomas.

D S Minckler1, D K Heuer, B Hasty, G Baerveldt, R C Cutting, W E Barlow.   

Abstract

Ninety patients with medically uncontrollable glaucomas and poor surgical prognoses received single-plate Molteno implants (Optomat Supplies, Dunedin, New Zealand) without postoperative adjunctive systemic antifibrosis therapy. Eleven patients had insufficient follow-up for assessment of intraocular pressure (IOP) or visual acuity outcome. The initial Molteno implant procedures in the remaining 79 patients were successful (IOP less than or equal to 21 mmHg with at least 6 months' follow-up) in 26 (63%) of the 41 patients older than 12 years of age with non-neovascular glaucomas in aphakia/pseudophakia; 7 (70%) of the 10 patients older than 12 years of age with non-neovascular glaucomas in phakic eyes after failed filtering surgery; 7 (47%) of the 15 patients with neovascular glaucomas; and 7 (54%) of the 13 patients younger than 13 years of age with non-neovascular glaucomas. The visual acuities remained within one line of their preoperative levels or improved in 31 (76%) of the 41 aphakic or pseudophakic eyes with non-neovascular glaucomas; 3 (30%) of the 10 phakic eyes with non-neovascular glaucomas after failed filtering surgery; 10 (67%) of the 15 eyes with neovascular glaucomas; and 9 (100%) of the 9 eyes with non-neovascular glaucomas in patients younger than 13 years of age on whom Snellen acuity was available.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3211496     DOI: 10.1016/s0161-6420(88)33029-0

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  24 in total

1.  Survival analysis for success of Molteno tube implants.

Authors:  D C Broadway; M Iester; M Schulzer; G R Douglas
Journal:  Br J Ophthalmol       Date:  2001-06       Impact factor: 4.638

2.  Measurement of Gamma-Irradiated Corneal Patch Graft Thickness After Aqueous Drainage Device Surgery.

Authors:  Regina A de Luna; Ameera Moledina; Jiangxia Wang; Henry D Jampel
Journal:  JAMA Ophthalmol       Date:  2017-09-01       Impact factor: 7.389

3.  Baerveldt implant in refractory glaucoma: long-term results and factors influencing outcome.

Authors:  S Roy; E Ravinet; A Mermoud
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

4.  Clinicopathological findings 11 months after implantation of a functioning aqueous-drainage silicone implant.

Authors:  W Philipp; G Klima; K Miller
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1990       Impact factor: 3.117

Review 5.  Aqueous shunts for glaucoma.

Authors:  D S Minckler; S S Vedula; T J Li; M C Mathew; R S Ayyala; B A Francis
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

Review 6.  Glaucoma drainage devices; past, present, and future.

Authors:  K S Lim; B D Allan; A W Lloyd; A Muir; P T Khaw
Journal:  Br J Ophthalmol       Date:  1998-09       Impact factor: 4.638

Review 7.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

8.  Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma.

Authors:  J S Lai; A S Poon; J K Chua; C C Tham; A T Leung; D S Lam
Journal:  Br J Ophthalmol       Date:  2000-07       Impact factor: 4.638

9.  Treatment outcomes in the Tube Versus Trabeculectomy (TVT) study after five years of follow-up.

Authors:  Steven J Gedde; Joyce C Schiffman; William J Feuer; Leon W Herndon; James D Brandt; Donald L Budenz
Journal:  Am J Ophthalmol       Date:  2012-01-15       Impact factor: 5.258

10.  Evaluation of Ahmed glaucoma valve implantation through a needle-generated scleral tunnel in Mexican children with glaucoma.

Authors:  Oscar Albis-Donado; Félix Gil-Carrasco; Rafael Romero-Quijada; Ravi Thomas
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.