Literature DB >> 1306663

Outcome of White pump shunt surgery for neovascular glaucoma in Asians.

E Chihara1, H Kubota, T Takanashi, N Nao-i.   

Abstract

We compared the effect of seton (White pump shunt) surgery (16 eyes) with that of trabeculectomy and 5-fluorouracil (31 eyes) in treating 38 Asian patients with medically uncontrollable neovascular glaucoma. We found the probability of long-term success (intraocular pressure < or = 26 > or = 5 mm Hg) of seton surgery (53.0% at 3 years) to be similar to that obtained following trabeculectomy with adjunctive 5-fluorouracil (45.4% at 3 years). However, 3 years postoperatively, the probability of the preservation of visual acuity was significantly greater following trabeculectomy than seton surgery (67.1% vs 23.1%; P < .05). In addition, the prevalence of postoperative complications was higher with the seton procedure (P < .001). The loss of endothelial cells 6 months postoperatively was more marked with seton surgery than with trabeculectomy, whether the shunt device touched the cornea (P < .000001) or not (P < .0005). In conclusion, White's pump shunt was effective in lowering the IOP of eyes with neovascular glaucoma. However, care must be taken to prevent postoperative complications, the incidence of which exceeded those observed following trabeculectomy with adjunctive 5-fluorouracil.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1306663

Source DB:  PubMed          Journal:  Ophthalmic Surg        ISSN: 0022-023X


  7 in total

Review 1.  Aqueous shunts for glaucoma.

Authors:  D S Minckler; S S Vedula; T J Li; M C Mathew; R S Ayyala; B A Francis
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

2.  Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma.

Authors:  J S Lai; A S Poon; J K Chua; C C Tham; A T Leung; D S Lam
Journal:  Br J Ophthalmol       Date:  2000-07       Impact factor: 4.638

3.  Preservation of corneal endothelium after pars plana tube insertion of the Ahmed glaucoma valve.

Authors:  Etsuo Chihara; Mitsuyoshi Umemoto; Masaki Tanito
Journal:  Jpn J Ophthalmol       Date:  2011-12-28       Impact factor: 2.447

Review 4.  Endophthalmitis associated with the Ahmed glaucoma valve implant.

Authors:  A A Al-Torbak; S Al-Shahwan; I Al-Jadaan; A Al-Hommadi; D P Edward
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

5.  The Ahmed glaucoma valve in neovascular glaucoma (An AOS Thesis).

Authors:  Peter A Netland
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

6.  The outcome of the Ahmad Glaucoma Valve implantation for refractory glaucoma in Kuwait.

Authors:  Adel M Aljazzaf; Sidky M A Abdelmoaty; Abdelmutalib H Behbehani; Ahmad A Abdulmuez; Hadeel A Aljazzaf
Journal:  Saudi J Ophthalmol       Date:  2012-10-27

7.  Tube Exposure Repair.

Authors:  Stirbu Oana; Jorge Vila
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.