Literature DB >> 9932995

Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant.

M C Huang1, P A Netland, A L Coleman, S W Siegner, M R Moster, R A Hill.   

Abstract

PURPOSE: We studied the intermediate-term clinical experience with the Ahmed Glaucoma Valve implant (New World Medical, Inc, Rancho Cucamonga, California).
METHODS: In this multicenter, retrospective case series, we studied 159 eyes (144 patients) treated with the Ahmed Glaucoma Valve with a mean +/- SEM (standard error of mean) follow-up of 13.4 +/- 0.7 months (range, 4 to 44 months). The mean +/- SEM age was 60.9 +/- 1.9 years (range, 0.1 to 103 years). Surgical success was defined as intraocular pressure less than 22 mm Hg and greater than 5 mm Hg without additional glaucoma surgery and without loss of light perception. Postoperative use of antiglaucoma medications was not a criterion for success or failure. The definition of hypotony was intraocular pressure of 5 mm Hg or less in two consecutive visits.
RESULTS: Intraocular pressure was reduced from a mean of 32.7 +/- 0.8 mm Hg before surgery to 15.9 +/- 0.6 mm Hg (P < .0001) at the most recent follow-up after surgery. The number of antiglaucoma medications was decreased from 2.7 +/- 0.1 before surgery to 1.1 +/- 0.1 after surgery (P < .0001). The cumulative probability of success was 87% at 1 year and 75% at 2 years after surgery (Kaplan-Meier life-table analysis). Postoperatively, 24 (15%) of 159 eyes had intraocular pressure greater than or equal to 22 mm Hg. The visual acuity was improved or within one Snellen line in 131 eyes (82%). Complications occurred in 75 eyes (47%), the majority of which did not affect surgical outcome. The most common complication was obstruction of the tube, which was observed in 17 eyes (11%). Transient postoperative hypotony was found in 13 eyes (8%).
CONCLUSIONS: The Ahmed Glaucoma Valve implant is effective in lowering intraocular pressure, and postoperative hypotony is not commonly associated with this implant.

Entities:  

Mesh:

Year:  1999        PMID: 9932995     DOI: 10.1016/s0002-9394(98)00394-8

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  61 in total

Review 1.  Aqueous shunts for glaucoma.

Authors:  D S Minckler; S S Vedula; T J Li; M C Mathew; R S Ayyala; B A Francis
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

2.  A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery.

Authors:  G Ainsworth; A Rotchford; H S Dua; A J King
Journal:  Br J Ophthalmol       Date:  2006-04       Impact factor: 4.638

3.  [New concepts for pressure-controlled glaucoma implants].

Authors:  R Allemann; O Stachs; K Falke; W Schmidt; S Siewert; K Sternberg; B Chichkov; A Wree; K-P Schmitz; R F Guthoff
Journal:  Ophthalmologe       Date:  2013-08       Impact factor: 1.059

4.  Clinical experience of e-PTFE membrane implant surgery for refractory glaucoma.

Authors:  C Kim; Y Kim; S Choi; S Lee; B Ahn
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

Review 5.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

6.  Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma.

Authors:  J S Lai; A S Poon; J K Chua; C C Tham; A T Leung; D S Lam
Journal:  Br J Ophthalmol       Date:  2000-07       Impact factor: 4.638

7.  Ahmed glaucoma valve implant: experience in East Africa.

Authors:  D O Kiage; D Gradin; S Gichuhi; K F Damji
Journal:  Middle East Afr J Ophthalmol       Date:  2009-07

8.  Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma.

Authors:  Manuel Diaz-Llopis; David Salom; Salvador García-Delpech; Patricia Udaondo; Jose Maria Millan; J Fernando Arevalo
Journal:  Clin Ophthalmol       Date:  2010-05-06

9.  Evaluation of Ahmed glaucoma valve implantation through a needle-generated scleral tunnel in Mexican children with glaucoma.

Authors:  Oscar Albis-Donado; Félix Gil-Carrasco; Rafael Romero-Quijada; Ravi Thomas
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

Review 10.  [Glaucoma drainage devices].

Authors:  H Thieme
Journal:  Ophthalmologe       Date:  2009-12       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.