| Literature DB >> 23885971 |
Yung-Hsiang Kao1, Jeffrey D Steinberg, Young-Soon Tay, Gabriel Ky Lim, Jianhua Yan, David W Townsend, Charley A Budgeon, Jan A Boucek, Roslyn J Francis, Timothy St Cheo, Mark C Burgmans, Farah G Irani, Richard Hg Lo, Kiang-Hiong Tay, Bien-Soo Tan, Pierce Kh Chow, Somanesan Satchithanantham, Andrew Eh Tan, David Ce Ng, Anthony Sw Goh.
Abstract
BACKGROUND: Coincidence imaging of low-abundance yttrium-90 (90Y) internal pair production by positron emission tomography with integrated computed tomography (PET/CT) achieves high-resolution imaging of post-radioembolization microsphere biodistribution. Part 2 analyzes tumor and non-target tissue dose-response by 90Y PET quantification and evaluates the accuracy of tumor 99mTc macroaggregated albumin (MAA) single-photon emission computed tomography with integrated CT (SPECT/CT) predictive dosimetry.Entities:
Year: 2013 PMID: 23885971 PMCID: PMC3733999 DOI: 10.1186/2191-219X-3-57
Source DB: PubMed Journal: EJNMMI Res Impact factor: 3.138
Figure 1Example of a Y PET/CT phantom scan with maximum intensity projection image. (a) Trans-axial, (b) coronal, and (c) sagittal planes. This scan shows our lowest tested vial sediment activity of 3.5 MBq (≈3 MBq/ml). The upper PET visual display threshold of this scan was adjusted to 114% (2,000 kBq/ml) to minimize visual interference from background noise [1]. (d) Maximum intensity projection image of the same phantom scan (arrow indicates vial sediment) with the upper PET visual display threshold adjusted to 1% (20 kBq/ml) to reveal the underlying background noise as an example to readers [1].
Figure 2Detector linearity. Linear regression line (dotted) of total vial sediment activities quantified by 90Y PET versus that of a dose calibrator.
Figure 3Patient 9. 90Y radioembolization of an organ other than the liver. KIT-negative GIST with bulky metastasis to the right adrenal gland, refractory to tyrosine kinase inhibitors. Angiography was previously shown in part 1 [1]. (a) Catheter-directed CT angiogram of the right inferior adrenal artery delineates the targeted right adrenal tumor measuring 10.1 × 6.3 cm. (b) Post-radioembolization 90Y PET/CT depicts microsphere biodistribution in high resolution, with concordant activity within targeted regions of contrast-enhancing tumor. Low-grade activity seen in the adjacent right liver lobe is due to 90Y radioembolization of a segment IV metastasis. (c) Isodose map by voxel dosimetry of the corresponding trans-axial slice of the right adrenal tumor provides a visual representation of dose heterogeneity within the tumor and adjacent right liver lobe and displays the full dose range from 0 to >1,000 Gy. (d) Follow-up contrast-enhanced CT of the abdomen at 9.5 months shows a moderate size reduction to 7.6 × 4.6 cm, representing a partial response.
Figure 4Y DVH of the right adrenal gland GIST metastasis generated by Y PET voxel dosimetry. Continued from Figure 3. A partial response was achieved at D70 53 Gy.
Tumor Y dose-response by dose-volume histograms
| 23 | HCC | ≈2.4a | ≈74a | ≈47a | ≈108a | 3 | Complete |
| 8 | HCC | ≈4.7a | ≈101a | ≈71a | ≈168a | 2.8 | Complete |
| 23 | HCC | 25.0 | 142 | 80 | 263 | 3 | Complete |
| 23 | HCC | 36.6 | 122 | 77 | 215 | 3 | Complete |
| 21 | HCC | 74.4 | 213 | 91 | 425 | 5.5 | Complete |
| 23 | HCC | 149.3 | 89 | 65 | 137 | 3 | Partial |
| 1 | HCC | 1,162.3 | 85 | 64 | 151 | 1.8 | Minor |
| 2 | HCC | 1,414.4 | 37 | 45 | 105 | 6.7 | Stable |
| 19 | HCC | 3,341.1 | 40 | 28 | 77 | 12 | Partial; adjuvant sorafenib |
| 17 | Cholangiocarcinoma | 345.9 | 90 | 63 | 120 | 3.3 | Complete |
| 9 | Adrenal GIST | 399.5 | 53 | 41 | 121 | 9.5 | Partial |
aSubject to partial volume effect and excluded from cross-analysis in Figure 5.
Figure 5Y DVH of seven HCC tumors, ranging in size from 25.0 to 3,341.1 cm.
Figure 6Patient 10. (a) Catheter-directed CT angiogram of the anterior branch of the right hepatic artery, supplying segments V and VIII, demonstrates contrast enhancement of a large portal vein tumor thrombus (arrow). (b, c) A 90Y PET VOI of the activity within the portal vein tumor thrombus was defined by volumetric isocontour thresholding, visually constrained to its anatomical margins as seen on the catheter-directed CT angiography. Within this VOI, the mean 90Y radioconcentration at the time of scan (5,239.8 kBq/ml) was decay-corrected back to the time of 90Y radioembolization (6,653 kBq/ml). By 90Y MIRD macrodosimetry, the mean absorbed dose of the portal vein tumor thrombus was approximately 316 Gy within the VOI. (d) Follow-up triphasic CT of the liver in the arterial phase at 4 months post-radioembolization demonstrates a complete lack of contrast enhancement within the VOI (arrow), suggesting a complete response and clinically validates the 90Y PET quantification.
Y dose-response of HCC portal vein tumor thrombosis by MIRD macrodosimetry
| 10 | Main portal vein | 316 | 4 | Complete |
| 14 | Main portal vein | 248 | 4 | Complete |
Figure 7Patient 17. Non-target 90Y activity along the gastric greater curve causing CTCAE grade 3 toxicity [1]. A 90Y PET VOI of the activity along the gastric greater curve was defined by volumetric isocontour thresholding, visually constrained to its CT anatomical margins, shown here in (a) trans-axial, (b) coronal, and (c) sagittal planes. Within this VOI, the mean 90Y radioconcentration at the time of scan (813.1k Bq/ml) was decay-corrected back to the time of 90Y radioembolization (1,021.5 kBq/ml). By 90Y MIRD macrodosimetry, the non-target mean absorbed dose to the gastric greater curve was approximately 49 Gy within the VOI. Gastroscopy and biopsy findings were reported in part 1 [1].
Y dose-response of non-target activity in viscera by MIRD macrodosimetry
| 14 | Gastric anterior wall | 18 | 5.6 | Asymptomatic |
| 17 | Gastric greater curve | 49 | 3.3 | Gastritis |
| 17 | Gastric pylorus | 65 | 3.3 | Ulceration |
| 17 | Proximal duodenum | 53 | 3.3 | Duodenitis |
Y dose-response of non-target activity in the right kidney by dose-volume histograms (patient 9)
| Right | 198.3 | 34 | 18 | 12 | Stable |
| Combined bilateral | 381.6 | 8 | 9 | As above | As above |