Literature DB >> 23874255

Total hip arthroplasty at the rothman institute.

Matthew S Austin1, Carlos A Higuera, Richard H Rothman.   

Abstract

BACKGROUND: Total hip arthroplasty (THA) is one of the most successful surgical interventions devised in modern times. Attempts to change the current THA procedure with unproven innovations bring the risk of increased failure rates while trying to improve the benefit of the surgery. QUESTIONS/PURPOSES: This manuscript examines the evolution of THA at the Rothman Institute illustrating the key elements that lead the success of this procedure at this institution. These key elements include femoral stem design, use of highly crossed-linked polyethylene and use of pain and rehabilitation protocols. We attempted to describe the long-term results regarding safety, effectiveness, and durability of specific THA implant designs used at this institution drawing on reported evidence in the literature.
METHODS: The authors performed a review of peer-reviewed articles related to the Rothman Institute's experience with THA.
RESULTS: Total hip arthroplasty is an efficient, safe, and durable procedure. It is a highly successful operation to restore function and improve pain. The survivorship of THA procedures at the Rothman Institute is higher than 99% at 10 years based on mechanical failure. The use of collarless, tapered wedge femoral stem, highly crossed-linked polyethylene, and improved pain rehabilitation protocols have contributed to this success.
CONCLUSIONS: There is a well-documented long-term survivorship after THA. Future innovation in THA should address new challenges with younger and more demanding patients, rather than change current methods that have a proven good survivorship. This innovation depends mainly upon improvements in the bearing surfaces and advances in pain control and rehabilitation.

Entities:  

Keywords:  Arthroplasty; Hip; Total

Year:  2012        PMID: 23874255      PMCID: PMC3715633          DOI: 10.1007/s11420-012-9268-x

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  32 in total

1.  Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years.

Authors:  M Pospischill; K Knahr
Journal:  J Bone Joint Surg Br       Date:  2005-09

2.  Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review.

Authors:  Mark I Froimson; Jonathan Garino; Alan Machenaud; J P Vidalain
Journal:  J Arthroplasty       Date:  2007-01       Impact factor: 4.757

3.  A double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty.

Authors:  George T Calvert; Peter A Devane; Jan Fielden; Kathryn Adams; J Geoffrey Horne
Journal:  J Arthroplasty       Date:  2008-06-10       Impact factor: 4.757

4.  A highly crosslinked UHMWPE for CR and PS total knee arthroplasties.

Authors:  Aiguo Wang; Shi-Shen Yau; Aaron Essner; Lizeth Herrera; Michael Manley; John Dumbleton
Journal:  J Arthroplasty       Date:  2008-02-13       Impact factor: 4.757

5.  Patterns of osteolysis around total hip components inserted with and without cement.

Authors:  B Zicat; C A Engh; E Gokcen
Journal:  J Bone Joint Surg Am       Date:  1995-03       Impact factor: 5.284

6.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

7.  Long-term results with the cementless Alloclassic brand hip arthroplasty system.

Authors:  Herwig Pieringer; Vinzenz Auersperg; Walter Griessler; Nikolaus Böhler
Journal:  J Arthroplasty       Date:  2003-04       Impact factor: 4.757

8.  Clinical and roentgenographic evaluation of hydroxyapatite-augmented and nonaugmented porous total hip arthroplasty.

Authors:  M G Ciccotti; R H Rothman; W J Hozack; L Moriarty
Journal:  J Arthroplasty       Date:  1994-12       Impact factor: 4.757

9.  Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up.

Authors:  Karl F Orishimo; Alexandra M Claus; Christi J Sychterz; Charles A Engh
Journal:  J Bone Joint Surg Am       Date:  2003-06       Impact factor: 5.284

10.  Primary total hip arthroplasty with an uncemented femoral component: two- to seven-year results.

Authors:  Thomas Lettich; Mary G Tierney; Javad Parvizi; Peter F Sharkey; Richard H Rothman
Journal:  J Arthroplasty       Date:  2007-10       Impact factor: 4.757

View more
  3 in total

Review 1.  Dual Mobility in Total Hip Arthroplasty: Biomechanics, Indications and Complications-Current Concepts.

Authors:  Nilesh Patil; Prashant Deshmane; Ajit Deshmukh; Christopher Mow
Journal:  Indian J Orthop       Date:  2021-10-13       Impact factor: 1.033

Review 2.  Dual mobility cups in total hip arthroplasty.

Authors:  Ivan De Martino; Georgios Konstantinos Triantafyllopoulos; Peter Keyes Sculco; Thomas Peter Sculco
Journal:  World J Orthop       Date:  2014-07-18

3.  Tripolar Constrained and Dual Mobility Liners Are Both Successful When Cemented Into Tantalum Acetabular Revision Shells in Complex Revision Total Hip Arthroplasty.

Authors:  Joaquin Valenzuela; Neil R Bergman; Richard Hiscock
Journal:  Arthroplast Today       Date:  2022-02-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.