Literature DB >> 25035820

Dual mobility cups in total hip arthroplasty.

Ivan De Martino1, Georgios Konstantinos Triantafyllopoulos1, Peter Keyes Sculco1, Thomas Peter Sculco1.   

Abstract

Total hip arthroplasty (THA) is considered one of the most successful surgical procedures in orthopaedics. With the increase in the number of THAs performed in the world in the next decades, reducing or preventing medical and mechanical complications such as post-operative THA instability will be of paramount importance, particularly in an emerging health care environment based on quality control and patient outcome. Dual mobility acetabular component (also known as unconstrained tripolar implant) was introduced in France at the end of the 1970s as an alternative to standard sockets, to reduce the risk of THA dislocation in patients undergoing primary THA in France. Dual mobility cups have recently gained wider attention in the United States as an alternative option in the prevention and treatment of instability in both primary and revision THA and offer the benefit of increased stability without compromising clinical outcomes and implant longevity. In this article, we review the use of dual mobility cup in total hip arthroplasty in terms of its history, biomechanics, outcomes and complications based on more than 20 years of medical literature.

Entities:  

Keywords:  Dislocation; Dual mobility; Instability; Revision total hip arthroplasty; Total hip arthroplasty

Year:  2014        PMID: 25035820      PMCID: PMC4095010          DOI: 10.5312/wjo.v5.i3.180

Source DB:  PubMed          Journal:  World J Orthop        ISSN: 2218-5836


  61 in total

1.  Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: a 59 cases series with a mean 8 years' follow-up.

Authors:  F Leiber-Wackenheim; B Brunschweiler; M Ehlinger; A Gabrion; P Mertl
Journal:  Orthop Traumatol Surg Res       Date:  2011-01-26       Impact factor: 2.256

2.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

3.  Is a cementless dual mobility socket in primary THA a reasonable option?

Authors:  Moussa Hamadouche; Hervé Arnould; Bertrand Bouxin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  Total hip arthroplasty at the rothman institute.

Authors:  Matthew S Austin; Carlos A Higuera; Richard H Rothman
Journal:  HSS J       Date:  2012-04-17

5.  Unconstrained tripolar hip implants: effect on hip stability.

Authors:  Olivier Guyen; Qing Shan Chen; Jacques Bejui-Hugues; Daniel J Berry; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2007-02       Impact factor: 4.176

Review 6.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

9.  Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture.

Authors:  Sarunas Tarasevicius; Mantas Busevicius; Otto Robertsson; Hans Wingstrand
Journal:  BMC Musculoskelet Disord       Date:  2010-08-06       Impact factor: 2.362

10.  5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis.

Authors:  Georgios Digas; Johan Kärrholm; Jonas Thanner; Peter Herberts
Journal:  Acta Orthop       Date:  2007-12       Impact factor: 3.717

View more
  44 in total

Review 1.  Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective.

Authors:  Christian Fabry; Jean Langlois; Moussa Hamadouche; Rainer Bader
Journal:  Int Orthop       Date:  2015-10-01       Impact factor: 3.075

Review 2.  [Pertrochanteric femoral fractures in the elderly].

Authors:  G H Sandmann; P Biberthaler
Journal:  Unfallchirurg       Date:  2015-05       Impact factor: 1.000

3.  Imaging evaluation of polyethylene liner dissociation in total hip arthroplasty.

Authors:  Yoshimi Endo; Christian Geannette; William T Chang
Journal:  Skeletal Radiol       Date:  2019-05-18       Impact factor: 2.199

4.  Dual mobility cups in revision total hip arthroplasty.

Authors:  Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2016-12-08       Impact factor: 3.075

Review 5.  [Hip dislocation after revision arthroplasty : Risk assessment and treatment strategies].

Authors:  P M Prodinger; J Schauwecker; H Mühlhofer; N Harrasser; F Pohlig; C Suren; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 6.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

7.  Cause of irreducible dislocation of a re-revision THR.

Authors:  Evelyn Patricia Murphy; Christopher Fenelon; Shane Russell; Finbarr Condon
Journal:  BMJ Case Rep       Date:  2018-06-04

8.  Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

Authors:  Chahine Assi; Elie El-Najjar; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2017-01-10       Impact factor: 3.075

9.  Total Hip Arthroplasty Dislocations Are More Complex Than They Appear: A Case Report of Intraprosthetic Dislocation of an Anatomic Dual-Mobility Implant After Closed Reduction.

Authors:  Bradford S Waddell; Ivan De Martino; Thomas Sculco; Peter Sculco
Journal:  Ochsner J       Date:  2016

Review 10.  Wear of dual-mobility cups: a review article.

Authors:  Anna Di Laura; Harry Hothi; Clement Battisti; Arianna Cerquiglini; Johann Henckel; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-12-09       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.