Literature DB >> 17197301

Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review.

Mark I Froimson1, Jonathan Garino, Alan Machenaud, J P Vidalain.   

Abstract

The performance of, and periprosthetic bone response to, a tapered, titanium (Ti6Al4V), hydroxyapatite-coated femoral hip prosthesis was evaluated at minimum of 10 years of follow-up. Data were prospectively collected on 147 consecutive primary hip arthroplasties performed in 133 patients by a single surgeon during a 2-year interval. Clinical and radiographic analyses of 96 hips in 86 patients were independently performed by 2 surgeons who were not involved in the care of these patients. There were no cases of aseptic loosening of the femoral component. Subsidence and stress shielding occurred in 5% and 2% of cases, respectively, and was not clinically significant. In all 15 hips that required revision of the acetabular component, the femoral component was found to be well fixed, without any occurrence of distal osteolysis. This femoral design provided reliable osseointegration that was durable at a mean of 11.5 years of follow-up.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17197301     DOI: 10.1016/j.arth.2006.03.003

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  20 in total

1.  Total hip arthroplasty at the rothman institute.

Authors:  Matthew S Austin; Carlos A Higuera; Richard H Rothman
Journal:  HSS J       Date:  2012-04-17

2.  Case report: Cementless stem stabilization after intraoperative fracture: a radiostereometric analysis.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2009-09-17       Impact factor: 4.176

3.  Early Post-operative Periprosthetic Femur Fracture in the Presence of a Non-cemented Tapered Wedge Femoral Stem.

Authors:  H John Cooper; José A Rodriguez
Journal:  HSS J       Date:  2010-04-02

4.  Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results.

Authors:  Hans D Carl; Jan Ploetzner; Bernd Swoboda; Gerd Weseloh; Lutz Arne Mueller
Journal:  Rheumatol Int       Date:  2009-12-18       Impact factor: 2.631

5.  Is there any difference between tapered titanium stems with similar geometry and hydroxyapatite coating?

Authors:  G Cinotti; G Mazzotta; F Romana Ripani; G La Torre; G Giannicola
Journal:  Musculoskelet Surg       Date:  2019-01-08

6.  Development of periprosthetic bone mass density around the cementless Metha® short hip stem during three year follow up-a prospective radiological and clinical study.

Authors:  Laura Augustin; Sarah Boller; Cathrein Bobach; Alexander Jahnke; Gafar Adam Ahmed; Markus Rickert; Bernd Alexander Ishaque
Journal:  Int Orthop       Date:  2018-09-03       Impact factor: 3.075

7.  Twenty-year results of the cementless Corail stem.

Authors:  Jean-Pierre Vidalain
Journal:  Int Orthop       Date:  2010-09-03       Impact factor: 3.075

8.  Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Vanessa Wells; John R Field; Stuart A Callary
Journal:  Int Orthop       Date:  2009-12-13       Impact factor: 3.075

9.  The enhanced effect of surface microstructured porous titanium on adhesion and osteoblastic differentiation of mesenchymal stem cells.

Authors:  J Yang; J Wang; T Yuan; X D Zhu; Z Xiang; Y J Fan; X D Zhang
Journal:  J Mater Sci Mater Med       Date:  2013-06-19       Impact factor: 3.896

10.  Radiographic Subsidence in Asymptomatic Patients After THR Using the Furlong Active HAP Stem.

Authors:  José Cordero-Ampuero; Pablo Peñalver; Rodrigo Antón; María Galán; Enrique Cordero
Journal:  HSS J       Date:  2013-06-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.