Literature DB >> 12728424

Long-term results with the cementless Alloclassic brand hip arthroplasty system.

Herwig Pieringer1, Vinzenz Auersperg, Walter Griessler, Nikolaus Böhler.   

Abstract

The first 100 Alloclassic (Centerpulse, Winterthur, Switzerland) hip prostheses implanted at Allgemeines Krankenhaus Linz were examined in this study. All cases involved primary total hip arthroplasty. Of these 100, 75 could be followed up clinically and radiologically. All living patients were contacted by telephone. The follow-up period was at least 10 years. If the endpoint is defined as removal of the prosthesis due to aseptic loosening, the survival rate was 96.9% for the cup and 100% for the stem after 132 months. The average Harris Hip Score was 85.4 points. Radiolucent lines and osteolyses were found primarily in the proximal zones of the stem. Copyright 2003 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2003        PMID: 12728424     DOI: 10.1054/arth.2003.50045

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  Long-term follow-up of primary total hip arthroplasty with the Alloclassic Variall system.

Authors:  Josef Hochreiter; Giovanni Brusaferri; Klaus Kirschbichler; Katja Emmanuel
Journal:  Int Orthop       Date:  2015-08-18       Impact factor: 3.075

2.  Three-dimensional stress analysis of threaded cups - a finite element analysis.

Authors:  U Witzel; W Rieger; H Effenberger
Journal:  Int Orthop       Date:  2007-02-21       Impact factor: 3.075

3.  Total hip arthroplasty at the rothman institute.

Authors:  Matthew S Austin; Carlos A Higuera; Richard H Rothman
Journal:  HSS J       Date:  2012-04-17

Review 4.  Correlation between patient age at total hip replacement surgery and lifeexpectancy.

Authors:  Carlos Roberto Schwartsmann; Leandro de Freitas Spinelli; Leonardo Carbonera Boschin; Anthony Kerbes Yépez; Marcus Vinicius Crestani; Marcelo Faria Silva
Journal:  Acta Ortop Bras       Date:  2015 Nov-Dec       Impact factor: 0.513

5.  Versatile application of short stem during total hip arthroplasty.

Authors:  Kwang-Jun Oh; Jae-Hyuk Yang
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-11-16

6.  Radiological identification of Zweymüller-type femoral stem prosthesis in revision cases.

Authors:  Saverio Affatato; Saverio Comitini; Matteo Fosco; Aldo Toni; Domenico Tigani
Journal:  Int Orthop       Date:  2016-02-29       Impact factor: 3.075

7.  Revision hip arthroplasty with a rectangular tapered cementless stem: a retrospective study of the SLR-Plus stem at a mean follow-up of 4.1 years.

Authors:  Iker Uriarte; Jesús Moreta; Laura Cortés; Lucía Bernuy; Urko Aguirre; José Luis Martínez de Los Mozos
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-10-15

8.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

9.  Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population.

Authors:  Peteris Studers; Danils Belajevs; Vitolds Jurkevics; Peteris Likums
Journal:  Int Orthop       Date:  2015-07-30       Impact factor: 3.075

10.  [Results of cementless hip arthroplasty].

Authors:  A Grübl
Journal:  Radiologe       Date:  2006-09       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.