Literature DB >> 18210089

[Alternative materials and solutions in total knee arthroplasty for patients with metal allergy].

R Bader1, P Bergschmidt, A Fritsche, S Ansorge, P Thomas, W Mittelmeier.   

Abstract

The annual number of total knee replacement implantations is rising continuously. A progressive cutaneous hypersensitivity rate against metallic materials in the population has been registered which can lead to an increase of allergy-induced reactions associated with implant loosening in the future although the correlation with an allergic cutaneous sensitisation has not been proven in all cases. On apparent allergy against metallic implant components different alternative solutions to standard endoprostheses should be taken into account for primary implantation or revision of total knee replacement, for example the application of implant components without metallic elements (e.g. ceramics), the use of non-allergic metallic implants, such as titanium or ZrNb alloys, or potential allergy-inducing metallic materials after masking the implant surface using a suitable coating. In the case of primary or revision surgery most patients with metal allergy are treated with a Ti(Nb)N-coated knee implant made of cobalt-chrome or titanium alloys in our hospital. Within an international multi-centre study we are currently implanting a newly developed knee endoprosthesis system with a ceramic femoral component as an alternative.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18210089     DOI: 10.1007/s00132-007-1189-x

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  19 in total

Review 1.  [Failure analysis of total knee replacement. Basics and methodological aspects of the damage analysis].

Authors:  R Bader; W Mittelmeier; E Steinhauser
Journal:  Orthopade       Date:  2006-09       Impact factor: 1.087

2.  Surface damage to an Oxinium femoral head prosthesis after dislocation.

Authors:  G T Evangelista; E Fulkerson; F Kummer; P E Di Cesare
Journal:  J Bone Joint Surg Br       Date:  2007-04

3.  Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies.

Authors:  Alan M Kop; Colin Whitewood; Don J L Johnston
Journal:  J Arthroplasty       Date:  2007-04-20       Impact factor: 4.757

4.  [Safety aspects in the coating of titanium slide components].

Authors:  U Fink
Journal:  Orthopade       Date:  1997-02       Impact factor: 1.087

5.  The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating.

Authors:  M T Raimondi; R Pietrabissa
Journal:  Biomaterials       Date:  2000-05       Impact factor: 12.479

6.  Wear-accelerated corrosion of Ti-6Al-4V and nitrogen-ion-implanted Ti-6Al-4V: mechanisms and influence of fixed-stress magnitude.

Authors:  R A Buchanan; E D Rigney; J M Williams
Journal:  J Biomed Mater Res       Date:  1987-03

Review 7.  [Allergy towards bone cement].

Authors:  P Thomas; A Schuh; B Summer; F Mazoochian; M Thomsen
Journal:  Orthopade       Date:  2006-09       Impact factor: 1.087

Review 8.  [Allergic reactions to implant materials].

Authors:  P Thomas
Journal:  Orthopade       Date:  2003-01       Impact factor: 1.087

9.  New surface modification for Ti-6Al-7Nb alloy: oxygen diffusion hardening (ODH).

Authors:  R M Streicher; H Weber; R Schön; M Semlitsch
Journal:  Biomaterials       Date:  1991-03       Impact factor: 12.479

10.  [Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty].

Authors:  S Hofmann; J Romero; E Roth-Schiffl; T Albrecht
Journal:  Orthopade       Date:  2003-06       Impact factor: 1.087

View more
  23 in total

1.  [Total knee replacement with ceramic femoral components: a national prospective multicenter study of clinical and radiological outcomes].

Authors:  P Bergschmidt; C Lohmann; D Ganzer; R Bader; S Finze; G Kundt; C Hauzeur; C Lukas; W Rüther; W Mittelmeier
Journal:  Orthopade       Date:  2011-03       Impact factor: 1.087

Review 2.  Allergy in Total Knee Replacement. Does It Exist?: Review Article.

Authors:  Martin Faschingbauer; Lisa Renner; Friedrich Boettner
Journal:  HSS J       Date:  2016-07-22

3.  [Implant allergies].

Authors:  P Thomas; M Thomsen
Journal:  Hautarzt       Date:  2010-03       Impact factor: 0.751

4.  [Preclinical evaluation of coated knee implants for allergic patients].

Authors:  J Reich; L Hovy; H-L Lindenmaier; R Zeller; J Schwiesau; P Thomas; T M Grupp
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

5.  [Use of allergy implants in Germany: results of a survey].

Authors:  M Thomsen; M Rozak; P Thomas
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

6.  [Histopathological particle algorithm. Particle identification in the synovia and the SLIM].

Authors:  V Krenn; P Thomas; M Thomsen; J P Kretzer; S Usbeck; L Scheuber; G Perino; W Rüther; R v Welser; F Hopf; M Huber
Journal:  Z Rheumatol       Date:  2014-09       Impact factor: 1.372

7.  Incidence of Metal Hypersensitivity in Orthopedic Surgical Patients Who Self-Report Hypersensitivity History.

Authors:  Mark Schultzel; Christopher M Klein; Marine Demirjian; Colin Blout; John M Itamura
Journal:  Perm J       Date:  2019-11-22

8.  Comparative Study of Clinical and Radiological Outcomes of Unconstrained Bicondylar Total Knee Endoprostheses with Anti-allergic Coating.

Authors:  Philipp Bergschmidt; Rainer Bader; Susanne Finze; Christoph Schulze; Guenther Kundt; Wolfram Mittelmeier
Journal:  Open Orthop J       Date:  2011-10-07

9.  Pain in a chromium-allergic patient with total knee arthroplasty: disappearance of symptoms after revision with a special surface-coated TKA--a case report.

Authors:  Marc Thomsen; Matthias Rozak; Peter Thomas
Journal:  Acta Orthop       Date:  2011-04-20       Impact factor: 3.717

10.  Ceramic femoral components in total knee arthroplasty - two year follow-up results of an international prospective multi-centre study.

Authors:  Philipp Bergschmidt; Rainer Bader; Dirk Ganzer; Christian Hauzeur; Christoph Lohmann; Wolfgang Rüther; Domenico Tigani; Nicola Rani; Fernando Lopez Prats; Claudio Zorzi; Vincenzo Madonna; Stefano Rigotti; Francesco Benazzo; Stefano Marco Paolo Rossi; Guenther Kundt; Hans Rudolf Bloch; Wolfram Mittelmeier
Journal:  Open Orthop J       Date:  2012-04-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.