Abstract

Users of Advanced Bionics, MedEl, and Cochlear Corp. implants balanced the loudness of trains of asymmetric pulses of opposite polarities presented in monopolar mode. For the Advanced Bionics and MedEl users the pulses were triphasic and consisted of a 32-μs central phase flanked by two 32-μs phases of opposite polarity and half the amplitude. The central phase was either anodic (TP-A) or cathodic (TP-C). For the Cochlear Corp. users, pulses consisted of two 32-μs phases of the same polarity separated by an 8-μs gap, flanked by two 32-μs phases of the opposite polarity, each of which was separated from the central portion by a 58-μs gap. The central portion of these quadraphasic pulses was either anodic (QP-A) or cathodic (QP-C), and all phases had the same amplitude. The current needed to achieve matched loudness was lower for the anodic than for the cathodic stimuli. This polarity effect was similar across all electrode locations studied, including the most apical electrode of the MedEl device which stimulates the very apex of the cochlea. In addition, when quadraphasic pulses were presented in bipolar mode, listeners reported hearing a lower pitch when the central portion was anodic at the more apical, than at the more basal, electrode. The results replicate previous reports that, unlike the results of most animal studies, human cochlear implant listeners are more sensitive to anodic than to cathodic currents, and extend those findings to a wider range of cochlear sites, implant types, and pulse shapes.

Entities:  

Mesh:

Year:  2013        PMID: 23862825     DOI: 10.1121/1.4807900

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  25 in total

1.  Effects of stimulus level and rate on psychophysical thresholds for interleaved pulse trains in cochlear implants.

Authors:  Michelle L Hughes; Jenny L Goehring; Jacquelyn L Baudhuin; Kendra K Schmid
Journal:  J Acoust Soc Am       Date:  2016-10       Impact factor: 1.840

2.  The Effect of Stimulus Polarity on the Relation Between Pitch Ranking and ECAP Spread of Excitation in Cochlear Implant Users.

Authors:  Emily R Spitzer; Sangsook Choi; Michelle L Hughes
Journal:  J Assoc Res Otolaryngol       Date:  2019-01-31

3.  The effect of polarity order and electrode-activation order on loudness in cochlear implant users.

Authors:  Ann E Todd; David M Landsberger
Journal:  J Acoust Soc Am       Date:  2018-08       Impact factor: 1.840

4.  Polarity Sensitivity as a Potential Correlate of Neural Degeneration in Cochlear Implant Users.

Authors:  Quentin Mesnildrey; Frédéric Venail; Robert P Carlyon; Olivier Macherey
Journal:  J Assoc Res Otolaryngol       Date:  2020-02-04

5.  Effect of Pulse Polarity on Thresholds and on Non-monotonic Loudness Growth in Cochlear Implant Users.

Authors:  Olivier Macherey; Robert P Carlyon; Jacques Chatron; Stéphane Roman
Journal:  J Assoc Res Otolaryngol       Date:  2017-01-30

6.  Characterizing Polarity Sensitivity in Cochlear Implant Recipients: Demographic Effects and Potential Implications for Estimating Neural Health.

Authors:  Michelle L Hughes
Journal:  J Assoc Res Otolaryngol       Date:  2022-01-06

7.  Effect of Stimulus Polarity on Physiological Spread of Excitation in Cochlear Implants.

Authors:  Emily R Spitzer; Michelle L Hughes
Journal:  J Am Acad Audiol       Date:  2017-10       Impact factor: 1.664

8.  An Instrumented Cochlea Model for the Evaluation of Cochlear Implant Electrical Stimulus Spread.

Authors:  Chen Jiang; Shreya Singhal; Thomas Landry; Iwan Roberts; Simone de Rijk; Tim Brochier; Tobias Goehring; Yu Tam; Robert Carlyon; George Malliaras; Manohar Bance
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.538

9.  A Comparison of Place-Pitch-Based Interaural Electrode Matching Methods for Bilateral Cochlear-Implant Users.

Authors:  Kenneth K Jensen; Stefano Cosentino; Joshua G W Bernstein; Olga A Stakhovskaya; Matthew J Goupell
Journal:  Trends Hear       Date:  2021 Jan-Dec       Impact factor: 3.293

10.  Effect of Pulse Rate and Polarity on the Sensitivity of Auditory Brainstem and Cochlear Implant Users to Electrical Stimulation.

Authors:  Robert P Carlyon; John M Deeks; Colette M McKay
Journal:  J Assoc Res Otolaryngol       Date:  2015-07-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.