An Instrumented Cochlea Model for the Evaluation of Cochlear Implant Electrical Stimulus Spread.

Chen Jiang, Shreya Singhal, Thomas Landry, Iwan Roberts, Simone de Rijk, Tim Brochier, Tobias Goehring, Yu Tam, Robert Carlyon, George Malliaras, Manohar Bance.   

Abstract

Cochlear implants use electrical stimulation of the auditory nerve to restore the sensation of hearing to deaf people. Unfortunately, the stimulation current spreads extensively within the cochlea, resulting in "blurring" of the signal, and hearing that is far from normal. Current spread can be indirectly measured using the implant electrodes for both stimulating and sensing, but this provides incomplete information near the stimulating electrode due to electrode-electrolyte interface effects. Here, we present a 3D-printed "unwrapped" physical cochlea model with integrated sensing wires. We integrate resistors into the walls of the model to simulate current spread through the cochlear bony wall, and "tune" these resistances by calibration with an in-vivo electrical measurement from a cochlear implant patient. We then use this model to compare electrical current spread under different stimulation modes including monopolar, bipolar and tripolar configurations. Importantly, a trade-off is observed between stimulation amplitude and current focusing among different stimulation modes. By combining different stimulation modes and changing intracochlear current sinking configurations in the model, we explore this trade-off between stimulation amplitude and focusing further. These results will inform clinical strategies for use in delivering speech signals to cochlear implant patients.

Entities:  

Mesh:

Year:  2021        PMID: 33587694      PMCID: PMC8215857          DOI: 10.1109/TBME.2021.3059302

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  32 in total

1.  Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants.

Authors:  L M Friesen; R V Shannon; D Baskent; X Wang
Journal:  J Acoust Soc Am       Date:  2001-08       Impact factor: 1.840

2.  Field patterns in a 3D tapered spiral model of the electrically stimulated cochlea.

Authors:  J J Briaire; J H Frijns
Journal:  Hear Res       Date:  2000-10       Impact factor: 3.208

3.  Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems.

Authors:  Jill B Firszt; Laura K Holden; Margaret W Skinner; Emily A Tobey; Ann Peterson; Wolfgang Gaggl; Christina L Runge-Samuelson; P Ashley Wackym
Journal:  Ear Hear       Date:  2004-08       Impact factor: 3.570

4.  Spatial channel interactions in cochlear implants.

Authors:  Qing Tang; Raul Benítez; Fan-Gang Zeng
Journal:  J Neural Eng       Date:  2011-07-13       Impact factor: 5.379

5.  Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents.

Authors:  A Kral; R Hartmann; D Mortazavi; R Klinke
Journal:  Hear Res       Date:  1998-07       Impact factor: 3.208

6.  Impedance measures for a better understanding of the electrical stimulation of the inner ear.

Authors:  Quentin Mesnildrey; Olivier Macherey; Philippe Herzog; Frédéric Venail
Journal:  J Neural Eng       Date:  2018-10-31       Impact factor: 5.379

7.  Current steering with partial tripolar stimulation mode in cochlear implants.

Authors:  Ching-Chih Wu; Xin Luo
Journal:  J Assoc Res Otolaryngol       Date:  2012-12-19

8.  Tetrapolar measurement of electrical conductivity and thickness of articular cartilage.

Authors:  J S Binette; M Garon; P Savard; M D McKee; M D Buschmann
Journal:  J Biomech Eng       Date:  2004-08       Impact factor: 2.097

9.  Cochlear implants.

Authors:  Olivier Macherey; Robert P Carlyon
Journal:  Curr Biol       Date:  2014-09-22       Impact factor: 10.834

10.  Using Spectral Blurring to Assess Effects of Channel Interaction on Speech-in-Noise Perception with Cochlear Implants.

Authors:  Tobias Goehring; Julie G Arenberg; Robert P Carlyon
Journal:  J Assoc Res Otolaryngol       Date:  2020-06-09
View more
  2 in total

1.  Management of Severe Facial Nerve Cross Stimulation by Cochlear Implant Replacement to Change Pulse Shape and Grounding Configuration: A Case-series.

Authors:  Susan T Eitutis; Robert P Carlyon; Yu Chuen Tam; Marina Salorio-Corbetto; Zebunnisa Vanat; Karen Tebbutt; Rhian Bardsley; Harry R F Powell; Shibasis Chowdhury; James R Tysome; Manohar L Bance
Journal:  Otol Neurotol       Date:  2022-04-01       Impact factor: 2.311

2.  Intra-Cochlear Current Spread Correlates with Speech Perception in Experienced Adult Cochlear Implant Users.

Authors:  Charles-Alexandre Joly; Pierre Reynard; Ruben Hermann; Fabien Seldran; Stéphane Gallego; Samar Idriss; Hung Thai-Van
Journal:  J Clin Med       Date:  2021-12-13       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.