Literature DB >> 23846766

Decreased central corneal thickness in ankylosing spondylitis.

Huseyin Ortak1, Ahmet Inanır, Selim Demir, Alper Uysal, Şafak Şahin, Mustafa Sağcan, Yalçın Önder, Sait Alim, Ayşe Kevser Demir.   

Abstract

Central corneal thickness and dry eye tests were evaluated in a study population consisting of 68 ankylosing spondylitis patients diagnosed according to the modified New York criteria, and 61 age-matched controls without ankylosing spondylitis. A full ophthalmological evaluation was performed on each subject. All subjects were screened for age, gender, HLA-B27, tear break-up time test, Schirmer test, and duration of disease. Central corneal thickness was measured under topical anesthesia with an ultrasonic pachymeter. The mean central corneal thickness was 537.3 ± 30.6 μm, range 462-600 μm, in ankylosing spondylitis patients, whereas it was 551.7 ± 25.2 μm, range 510-620 μm, in controls (p = 0.005). The Schirmer test result was 7.3 ± 5.9 mm for the ankylosing spondylitis patients and 11.7 ± 5.8 mm for the control group (p = 0.002). Tear break-up time was 7.3 ± 3.2 s for the ankylosing spondylitis patients and 14.0 ± 4.5 s for the control group (p < 0.001). The possibility of a thinner cornea should be taken into consideration in ankylosing spondylitis. In addition, attention must be given to lower dry eye tests in surgical interventions such as photorefractive keratectomy and laser in situ keratomileusis in ankylosing spondylitis patients.

Entities:  

Mesh:

Year:  2013        PMID: 23846766     DOI: 10.1007/s10792-013-9827-2

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  31 in total

1.  Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry.

Authors:  Jose Manuel González-Méijome; Alejandro Cerviño; Eva Yebra-Pimentel; Manuel A Parafita
Journal:  J Cataract Refract Surg       Date:  2003-01       Impact factor: 3.351

2.  Central corneal thickness measurements: using an ultrasonic instrument and 4 optical instruments.

Authors:  Ravaughn Williams; Barbara A Fink; P Ewen King-Smith; G Lynn Mitchell
Journal:  Cornea       Date:  2011-11       Impact factor: 2.651

3.  Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement.

Authors:  Jaime Aramberri; Luis Araiz; Ane Garcia; Igor Illarramendi; Jaione Olmos; Izaskun Oyanarte; Amaya Romay; Itxaso Vigara
Journal:  J Cataract Refract Surg       Date:  2012-09-18       Impact factor: 3.351

4.  Central corneal thickness measurements with different imaging devices and ultrasound pachymetry.

Authors:  Lai-Yong Tai; Keat-Ween Khaw; Choung-Min Ng; Visvaraja Subrayan
Journal:  Cornea       Date:  2013-06       Impact factor: 2.651

Review 5.  Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach.

Authors:  M J Doughty; M L Zaman
Journal:  Surv Ophthalmol       Date:  2000 Mar-Apr       Impact factor: 6.048

6.  Evaluation of diagnostic criteria for ankylosing spondylitis. A proposal for modification of the New York criteria.

Authors:  S van der Linden; H A Valkenburg; A Cats
Journal:  Arthritis Rheum       Date:  1984-04

Review 7.  [The cornea: stasis and dynamics].

Authors:  Teruo Nishida
Journal:  Nippon Ganka Gakkai Zasshi       Date:  2008-03

Review 8.  Corneal thickness in glaucoma screening, diagnosis, and management.

Authors:  James D Brandt
Journal:  Curr Opin Ophthalmol       Date:  2004-04       Impact factor: 3.761

9.  IL-17 disrupts corneal barrier following desiccating stress.

Authors:  C S De Paiva; S Chotikavanich; S B Pangelinan; J D Pitcher; B Fang; X Zheng; P Ma; W J Farley; K F Siemasko; J Y Niederkorn; M E Stern; D-Q Li; S C Pflugfelder
Journal:  Mucosal Immunol       Date:  2009-02-25       Impact factor: 7.313

10.  Effects of N-acetylcysteine on matrix metalloproteinase-9 secretion and cell migration of human corneal epithelial cells.

Authors:  T Ramaesh; K Ramaesh; S C Riley; J D West; B Dhillon
Journal:  Eye (Lond)       Date:  2012-07-06       Impact factor: 3.775

View more
  3 in total

1.  Involvement of Notch1/Hes signaling pathway in ankylosing spondylitis.

Authors:  Wei Xu; Chao-Ge Liang; Yi-Fan Li; Yun-Han Ji; Wen-Jun Qiu; Xian-Zhong Tang
Journal:  Int J Clin Exp Pathol       Date:  2015-03-01

2.  Biomechanical evaluation of cornea in patients with ankylosing spondylitis.

Authors:  Mehtap Caglayan; Ozge Sarac; Pinar Kosekahya; Sukran Erten; Berna Ayan; Nurullah Cagil
Journal:  Int Ophthalmol       Date:  2016-10-05       Impact factor: 2.031

3.  Improvement of conjunctival cytological grade and tear production in Ankylosing Spondylitis patients under TNF inhibitors: a long-term follow-up.

Authors:  Fany Solange Usuba; Carla Gonçalves Schahin Saad; Nadia Emi Aikawa; Priscila Novaes; Julio Cesar Bertacini Moraes; Ruth Miyuki Santo; Jozelio Freire Carvalho; Eloisa Bonfá; Milton Ruiz Alves
Journal:  Sci Rep       Date:  2020-01-15       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.