Literature DB >> 2384501

Endosteal erosion in association with stable uncemented femoral components.

W J Maloney1, M Jasty, W H Harris, J O Galante, J J Callaghan.   

Abstract

Sixteen cases of patients who had focal femoral osteolysis after total hip replacement without cement were identified. Fourteen of them were included in a retrospective review of 474 consecutive total hip replacements without cement in 441 patients who had been followed for at least two years. The criteria for inclusion in the study were focal osteolysis with a femoral component that appeared stable radiographically, and no subsidence or change of position of the implant. All but two patients were men and were quite active. The average age was forty-seven years (range, twenty to sixty-five years). Fourteen of the sixteen patients had an excellent clinical result (a Harris hip score of 90 points or more). In two patients, the hip replacement was revised and, in a third, a biopsy was done. In all three patients, the implant was found to be firmly fixed to the femur. In the two hips that were revised, extensive ingrowth of bone was demonstrated histologically, there was no evidence of infection, and a well defined fibrous membrane was found around the smooth portion of the stem. The histological specimens from these two hips contained focal aggregates of macrophages with particulate polyethylene and metallic debris. In the biopsy material from the hip that was not revised, a fine fibrous membrane lined a cystic cavity. Although the membrane contained an occasional macrophage, no foreign material was identified. Trabecular microfracture and osteoclastic resorption of bone were seen next to the fibrous lining. With one exception, osteolysis was not identified less than two years postoperatively. In most patients, osteolysis appeared after three years. This study showed that femoral osteolysis can occur around uncemented components.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2384501

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  37 in total

1.  Prosthetic Joint Infection.

Authors: 
Journal:  Curr Infect Dis Rep       Date:  1999-08       Impact factor: 3.725

2.  Current attitudes to total hip replacement in the younger patient: results of a national survey.

Authors:  T D Tennent; N J Goddard
Journal:  Ann R Coll Surg Engl       Date:  2000-01       Impact factor: 1.891

3.  Risk factors for poor hip flexion after total hip arthroplasty for the treatment of ankylosing spondylitis a multivariate analysis.

Authors:  Liang Zhang; Dejin Yang; Xinghua Yin; Yixin Zhou
Journal:  Clin Rheumatol       Date:  2014-03-21       Impact factor: 2.980

4.  A no-touch technique of loading bone cement for gun injection at total hip arthroplasty.

Authors:  J Rice; W Curtin; S K O'Rourke
Journal:  Ir J Med Sci       Date:  1996 Jan-Mar       Impact factor: 1.568

5.  Follow-up (6-9 years) results of the uncemented CLS Spotorno stem.

Authors:  J U Bulow; G Scheller; P Arnold; M Synatschke; L Jani
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

6.  Total hip replacement arthroplasty with Mallory-Head system--minimum ten-year follow-up results.

Authors:  Joo-Hyoun Song; Dong-Hyun Kim; Juyoung Kim
Journal:  Int Orthop       Date:  2012-08-04       Impact factor: 3.075

7.  Aggravation of inflammatory response by costimulation with titanium particles and mechanical perturbations in osteoblast- and macrophage-like cells.

Authors:  Heon Goo Lee; Anny Hsu; Hana Goto; Saqib Nizami; Jonathan H Lee; Edwin R Cadet; Peter Tang; Roya Shaji; Chandhanarat Chandhanayinyong; Seok Hyun Kweon; Daniel S Oh; Hesham Tawfeek; Francis Y Lee
Journal:  Am J Physiol Cell Physiol       Date:  2012-12-19       Impact factor: 4.249

8.  Cotyloplasty in cementless total hip arthroplasty for an insufficient acetabulum.

Authors:  Yong Lae Kim; Kwang Woo Nam; Jeong Joon Yoo; Young-Min Kim; Hee Joong Kim
Journal:  Clin Orthop Surg       Date:  2010-08-03

9.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

10.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

View more