Literature DB >> 22864458

Total hip replacement arthroplasty with Mallory-Head system--minimum ten-year follow-up results.

Joo-Hyoun Song1, Dong-Hyun Kim, Juyoung Kim.   

Abstract

PURPOSE: The purpose of this study was to assess the clinical and radiographic results of a total hip arthroplasty with the double tapered Mallory-Head system.
METHODS: The clinical and radiographic results of a consecutive series of 81 total hip replacements in 75 patients were reviewed 10-15 years (average 11.4 years) postoperatively. The patients' underlying conditions were avascular necrosis in 46 hips (57 %), osteoarthritis in 12 hips (15 %), RA in nine hips (11 %), and others. Clinical results were evaluated based on the modified Harris hip score and modified Merle d'Aubigné-Postel score. A radiographic analysis was performed.
RESULTS: The average modified Harris hip score improved from a preoperative score of 56 points to a postoperative 92 points. The average modified Merle d'Aubigné-Postel score was 15 points at the latest follow up, and 55 hips (68 %) were classified as the clinical grades of excellent or good results. One acetabular component was revised because of loosening, and one was revised for recurrent dislocation.
CONCLUSION: The clinical and radiological evaluations of the total hip replacements using the Mallory-Head system showed good results.

Entities:  

Mesh:

Year:  2012        PMID: 22864458      PMCID: PMC3460082          DOI: 10.1007/s00264-012-1627-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  31 in total

1.  Local response to biomaterials: bone loss in cementless femoral stems.

Authors:  J J Jacobs; J O Galante; D R Sumner
Journal:  Instr Course Lect       Date:  1992

2.  Results of the Harris-Galante cementless hip prosthesis.

Authors:  Y H Kim; V E Kim
Journal:  J Bone Joint Surg Br       Date:  1992-01

3.  Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components.

Authors:  C A Engh; P Massin; K E Suthers
Journal:  Clin Orthop Relat Res       Date:  1990-08       Impact factor: 4.176

4.  The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study.

Authors:  R D Heekin; J J Callaghan; W J Hopkinson; C G Savory; J S Xenos
Journal:  J Bone Joint Surg Am       Date:  1993-01       Impact factor: 5.284

5.  Revision arthroplasty with an isoelastic uncemented femoral stem.

Authors:  T J Niinimäki; J P Puranen; P K Jalovaara
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

6.  Ingrowth surfaces. Plasma spray coating to titanium alloy hip replacements.

Authors:  R B Bourne; C H Rorabeck; B C Burkart; P G Kirk
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

7.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

8.  Endosteal erosion in association with stable uncemented femoral components.

Authors:  W J Maloney; M Jasty; W H Harris; J O Galante; J J Callaghan
Journal:  J Bone Joint Surg Am       Date:  1990-08       Impact factor: 5.284

9.  Failure mechanisms of anatomic porous replacement I cementless total hip replacement.

Authors:  L D Dorr; K Lewonowski; M Lucero; M Harris; Z Wan
Journal:  Clin Orthop Relat Res       Date:  1997-01       Impact factor: 4.176

10.  The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. A retrospective matched-pair series.

Authors:  D D Goetz; E J Smith; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1994-08       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.