Literature DB >> 23830111

Carotid blood flow measurement accelerated by compressed sensing: validation in healthy volunteers.

Yuehui Tao1, Gabriel Rilling, Mike Davies, Ian Marshall.   

Abstract

Measurement of blood flow by cine phase-contrast MRI is a valuable technique in the study of arterial disease but is time consuming, especially for multi-slice (4D) studies. Compressed sensing is a modern signal processing technique that exploits sparse signal representations to enable sampling at lower than the conventional Nyquist rate. It is emerging as a powerful technique for the acceleration of MRI acquisition. In this study we evaluated the accuracy of phase-contrast carotid blood flow measurement in healthy volunteers using threefold undersampling of kt-space and compressed sensing reconstruction. Sixteen healthy volunteers were scanned at 1.5T with a retrospectively gated 2D cine phase-contrast sequence. Both fully sampled and three-fold accelerated scans were carried out to measure blood flow velocities in the common carotid arteries. The accelerated scans used a k-t variable density randomised sampling scheme and standard compressed sensing reconstruction. Flow rates were determined by integration of velocities within the manually segmented arteries. Undersampled measurements were compared with fully sampled results. Bland-Altman analysis found that peak velocities and flow rates determined from the compressed sensing scans were underestimated by 5% compared with fully sampled scanning. The corresponding figure for time-averaged flow was 3%. These acceptably small errors with a threefold reduction in scan time will facilitate future extension to 4D flow studies in clinical research and practice.
Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Acceleration; Carotid arteries; Carotid flow; Cine phase contrast; Compressed sensing; Phase contrast

Mesh:

Year:  2013        PMID: 23830111     DOI: 10.1016/j.mri.2013.05.009

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  13 in total

Review 1.  Compressed sensing MRI: a review of the clinical literature.

Authors:  Oren N Jaspan; Roman Fleysher; Michael L Lipton
Journal:  Br J Radiol       Date:  2015-09-24       Impact factor: 3.039

Review 2.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

3.  Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

Authors:  Jing Liu; Louise Koskas; Farshid Faraji; Evan Kao; Yan Wang; Henrik Haraldsson; Sarah Kefayati; Chengcheng Zhu; Sinyeob Ahn; Gerhard Laub; David Saloner
Journal:  MAGMA       Date:  2017-08-07       Impact factor: 2.310

4.  Improved acceleration of phase-contrast flow imaging with magnitude difference regularization.

Authors:  Taehoon Shin; Wanyong Shin
Journal:  Magn Reson Imaging       Date:  2019-12-02       Impact factor: 2.546

5.  Phase-contrast MRI with hybrid one and two-sided flow-encoding and velocity spectrum separation.

Authors:  Da Wang; Jiaxin Shao; Daniel B Ennis; Peng Hu
Journal:  Magn Reson Med       Date:  2016-08-09       Impact factor: 4.668

Review 6.  Advanced flow MRI: emerging techniques and applications.

Authors:  M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby
Journal:  Clin Radiol       Date:  2016-03-02       Impact factor: 2.350

Review 7.  Four-dimensional MRI flow examinations in cerebral and extracerebral vessels - ready for clinical routine?

Authors:  Susanne Schnell; Can Wu; Sameer A Ansari
Journal:  Curr Opin Neurol       Date:  2016-08       Impact factor: 5.710

Review 8.  Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption.

Authors:  Alice C Yang; Madison Kretzler; Sonja Sudarski; Vikas Gulani; Nicole Seiberlich
Journal:  Invest Radiol       Date:  2016-06       Impact factor: 6.016

9.  Phase contrast MRI with flow compensation view sharing.

Authors:  Da Wang; Jiaxin Shao; Stanislas Rapacchi; Matthew J Middione; Daniel B Ennis; Peng Hu
Journal:  Magn Reson Med       Date:  2014-02-14       Impact factor: 4.668

Review 10.  4D flow cardiovascular magnetic resonance consensus statement.

Authors:  Petter Dyverfeldt; Malenka Bissell; Alex J Barker; Ann F Bolger; Carl-Johan Carlhäll; Tino Ebbers; Christopher J Francios; Alex Frydrychowicz; Julia Geiger; Daniel Giese; Michael D Hope; Philip J Kilner; Sebastian Kozerke; Saul Myerson; Stefan Neubauer; Oliver Wieben; Michael Markl
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-10       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.