| Literature DB >> 23814380 |
M Jordan Ray1, Fawzi Mohammad, William B Taylor, Marco Cura, Clare Savage.
Abstract
Operator radiation exposure is an important occupational hazard compounded over the course of an interventional radiologist's career. This study compared operator radiation dose to the eye and head for different positions around the patient. Compared with cases performed from the femoral region, exposures were 1.8 times higher at the side, and 1.6 times higher at the head, using conventional aprons, table shields, and mobile suspended shields. Exposures were 99% lower when using a suspended personal radiation protection system in all positions. In conclusion, standing at the side or head results in higher head exposures in a conventional setup.Entities:
Year: 2013 PMID: 23814380 PMCID: PMC3684287 DOI: 10.1080/08998280.2013.11928971
Source DB: PubMed Journal: Proc (Bayl Univ Med Cent) ISSN: 0899-8280