Literature DB >> 21044993

Doses to operators during interventional radiology procedures: focus on eye lens and extremity dosimetry.

C Koukorava1, E Carinou, G Simantirakis, T G Vrachliotis, E Archontakis, C Tierris, P Dimitriou.   

Abstract

The present study is focused on the personnel doses during several types of interventional radiology procedures. Apart from the use of the official whole body dosemeters (thermoluminescence dosemeter type), measurements were performed to the extremities and the eyes using thermoluminescent loose pellets. The mean doses per kerma area product were calculated for the monitored anatomic regions and for the most frequent types of procedures. Higher dose values were measured during therapeutic procedures, especially embolisations. The maximum recorded doses during a single procedure were 1.8 mSv to the finger (nephrostomy), 2.1 mSv to the wrist (liver chemoembolisation), 0.6 mSv to the leg (brain embolisation) and 2.4 mSv to the eye (brain embolisation). The annual doses estimated for the operator with the highest workload according to the measurements and the system's log book were 90.4 mSv to the finger, 107.9 mSv to the wrist, 21.6 mSv to the leg and 49.3 mSv to the eye. Finally, the effect of the beam angulation (i.e. projection) and shielding equipment on the personnel doses was evaluated. The measurements were performed within the framework of the ORAMED (Optimization of RAdiation Protection for MEDical staff) project.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21044993     DOI: 10.1093/rpd/ncq328

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  9 in total

1.  Comparison of fluoroscopic operator eye exposures when working from femoral region, side, or head of patient.

Authors:  M Jordan Ray; Fawzi Mohammad; William B Taylor; Marco Cura; Clare Savage
Journal:  Proc (Bayl Univ Med Cent)       Date:  2013-07

2.  An investigation of the radiation doses to the lower legs and feet of staff undertaking interventional procedures.

Authors:  R E R Artschan; D S Brettle; K Chase; A Fender; P G Howells; S Buchan
Journal:  Br J Radiol       Date:  2014-03-06       Impact factor: 3.039

3.  Randomized comparison of long and short vascular sheaths in reduction of the operator radiation exposure during uterine artery embolization.

Authors:  Meng-Qiu Cao; Xue-Bin Zhang; Zhi-Guo Zhuang; Wei Zhou; Jian-Rong Xu; Yi-Cun Zhong
Journal:  Br J Radiol       Date:  2016-03-24       Impact factor: 3.039

Review 4.  Eye protection in interventional procedures.

Authors:  Beth A Schueler; Kenneth A Fetterly
Journal:  Br J Radiol       Date:  2021-10-01       Impact factor: 3.629

5.  How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

Authors:  Ah Na Kim; Young Jae Chang; Bo Kyung Cheon; Jae Hun Kim
Journal:  Korean J Pain       Date:  2014-03-28

6.  Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters.

Authors:  Qianjun Jia; Ziman Chen; Xianxian Jiang; Zhenjun Zhao; Meiping Huang; Jiahua Li; Jian Zhuang; Xiaoqing Liu; Tianyu Hu; Wensheng Liang
Journal:  Sci Rep       Date:  2017-02-07       Impact factor: 4.379

7.  A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan.

Authors:  Keisuke Nagamoto; Takashi Moritake; Koichi Nakagami; Koichi Morota; Satoru Matsuzaki; Naoki Kunugita
Journal:  J Occup Health       Date:  2021-01       Impact factor: 2.708

8.  Fluoroscopic Cranial Radiation Exposure in Spine Surgery: A Prospective Single-Center Evaluation in Operating Room Personnel.

Authors:  Laila Malani Mohammad; James Messegee; M Omar Chohan; Christopher L Taylor
Journal:  Int J Spine Surg       Date:  2019-02-22

9.  Physical analysis of the shielding capacity for a lightweight apron designed for shielding low intensity scattering X-rays.

Authors:  Seon Chil Kim; Jeong Ryeol Choi; Byeong Kyou Jeon
Journal:  Sci Rep       Date:  2016-07-27       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.