Literature DB >> 23810189

Diffusion-weighted MRI of the prostate at 3.0 T: comparison of endorectal coil (ERC) MRI and phased-array coil (PAC) MRI-The impact of SNR on ADC measurement.

Yousef Mazaheri1, H Alberto Vargas, Gregory Nyman, Amita Shukla-Dave, Oguz Akin, Hedvig Hricak.   

Abstract

PURPOSE: To compare ADC values measured from diffusion-weighted MR (DW-MR) images of the prostate obtained with both endorectal and phased-array coils (ERC+PAC) to those from DW-MRI images obtained with an eight-channel torso phased-array coil (PAC) at 3.0 T.
METHODS: The institutional review board issued a waiver of informed consent for this HIPAA-compliant study. Twenty-five patients with biopsy-proven prostate cancer underwent standard 3-T MRI using 2 different coil arrangements (ERC+PAC and PAC only) in the same session. DW-MRI at five b-values (0, 600, 1000, 1200, and 1500 s/mm(2)) were acquired using both coil arrangements. On b=0 images, signal-to-noise ratios (SNRs) were measured as the ratio of the mean signal from PZ and TZ ROIs to the standard deviation from the mean signal in an artifact-free ROI in the rectum. Matching regions-of-interest (ROIs) were identified in the peripheral zone and transition zone on ERC-MRI and PAC-MRI. For each ROI, mean ADC values for all zero and non-zero b-value combinations were computed.
RESULTS: Mean SNR with ERC-MRI at PZ (66.33 ± 27.07) and TZ (32.69 ± 12.52) was 9.27 and 5.52 times higher than with PAC-MRI ((7.32 ± 2.30) and (6.13 ± 1.56), respectively) (P<0.0001 for both). ADCs from DW-MR images obtained with all b-values in the PZ and TZ were significantly lower with PAC-MRI than with ERC-MRI (P<0.001 for all).
CONCLUSION: Lower SNR of DW-MR images of the prostate obtained with a PAC can significantly decrease ADC values at higher b-values compared to similar measurements obtained using the ERC. To address these requirements, clinical MR systems should have image processing capabilities which incorporate the noise distribution.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Diffusion-weighted MRI (DW-MRI); Endorectal coil (ERC); Phased-array coil (PAC); Prostate; Signal-to-noise ratio (SNR)

Mesh:

Year:  2013        PMID: 23810189     DOI: 10.1016/j.ejrad.2013.04.041

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  13 in total

1.  Update of the Standard Operating Procedure on the Use of Multiparametric Magnetic Resonance Imaging for the Diagnosis, Staging and Management of Prostate Cancer.

Authors:  Marc A Bjurlin; Peter R Carroll; Scott Eggener; Pat F Fulgham; Daniel J Margolis; Peter A Pinto; Andrew B Rosenkrantz; Jonathan N Rubenstein; Daniel B Rukstalis; Samir S Taneja; Baris Turkbey
Journal:  J Urol       Date:  2019-10-23       Impact factor: 7.450

2.  Improved performance of prostate DCE-MRI using a 32-coil vs. 12-coil receiver array.

Authors:  Stephen J Riederer; Eric A Borisch; Adam T Froemming; Roger C Grimm; Akira Kawashima; Lance A Mynderse; Joshua D Trzasko
Journal:  Magn Reson Imaging       Date:  2017-01-27       Impact factor: 2.546

3.  Influence of blade width and magnetic field strength on the ADC on PROPELLER DWI in head and neck.

Authors:  Tetsuo Sumikawa; Hidetake Yabuuchi; Chiharu Sumikawa; Yoshiteru Nakashima; Gouji Miura
Journal:  Neuroradiol J       Date:  2019-08-13

4.  Accelerating Prostate Diffusion-weighted MRI Using a Guided Denoising Convolutional Neural Network: Retrospective Feasibility Study.

Authors:  Elena A Kaye; Emily A Aherne; Cihan Duzgol; Ida Häggström; Erich Kobler; Yousef Mazaheri; Maggie M Fung; Zhigang Zhang; Ricardo Otazo; Hebert A Vargas; Oguz Akin
Journal:  Radiol Artif Intell       Date:  2020-08-26

5.  Reduced-FOV excitation decreases susceptibility artifact in diffusion-weighted MRI with endorectal coil for prostate cancer detection.

Authors:  Natalie Korn; John Kurhanewicz; Suchandrima Banerjee; Olga Starobinets; Emine Saritas; Susan Noworolski
Journal:  Magn Reson Imaging       Date:  2014-09-06       Impact factor: 2.546

Review 6.  The expanding landscape of diffusion-weighted MRI in prostate cancer.

Authors:  Andreas G Wibmer; Evis Sala; Hedvig Hricak; Hebert Alberto Vargas
Journal:  Abdom Radiol (NY)       Date:  2016-05

7.  An endovaginal MRI array with a forward-looking coil for advanced gynecological cancer brachytherapy procedures: Design and initial results.

Authors:  Akbar Alipour; Akila N Viswanathan; Ronald D Watkins; Hassan Elahi; Wolfgang Loew; Eric Meyer; Marc Morcos; Henry R Halperin; Ehud J Schmidt
Journal:  Med Phys       Date:  2021-10-08       Impact factor: 4.071

Review 8.  The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis.

Authors:  Chen Jie; Liu Rongbo; Tan Ping
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

Review 9.  Modern imaging and image-guided treatments of the prostate gland: MR and ablation for cancer and prostatic artery embolization for benign prostatic hyperplasia.

Authors:  João Lopes Dias; Tiago Bilhim
Journal:  BJR Open       Date:  2019-08-14

Review 10.  DCE-MRI, DW-MRI, and MRS in Cancer: Challenges and Advantages of Implementing Qualitative and Quantitative Multi-parametric Imaging in the Clinic.

Authors:  Jessica M Winfield; Geoffrey S Payne; Alex Weller; Nandita M deSouza
Journal:  Top Magn Reson Imaging       Date:  2016-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.