Literature DB >> 25200645

Reduced-FOV excitation decreases susceptibility artifact in diffusion-weighted MRI with endorectal coil for prostate cancer detection.

Natalie Korn1, John Kurhanewicz2, Suchandrima Banerjee3, Olga Starobinets2, Emine Saritas4, Susan Noworolski2.   

Abstract

The purposes of this study were to determine if image distortion is less in prostate MR apparent diffusion coefficient (ADC) maps generated from a reduced-field-of-view (rFOV) diffusion-weighted-imaging (DWI) technique than from a conventional DWI sequence (CONV), and to determine if the rFOV ADC tumor contrast is as high as or better than that of the CONV sequence. Fifty patients underwent a 3T MRI exam. CONV and rFOV (utilizing a 2D, echo-planar, rectangularly-selective RF pulse) sequences were acquired using b=600, 0s/mm(2). Distortion was visually scored 0-4 by three independent observers and quantitatively measured using the difference in rectal wall curvature between the ADC maps and T2-weighted images. Distortion scores were lower with the rFOV sequence (p<0.012, Wilcoxon Signed-Rank Test, n=50), and difference in distortion scores did not differ significantly among observers (p=0.99, Kruskal-Wallis Rank Sum Test). The difference in rectal curvature was less with rFOV ADC maps (26%±10%) than CONV ADC maps (34%±13%) (p<0.011, Student's t-test). In seventeen patients with untreated, biopsy confirmed prostate cancer, the rFOV sequence afforded significantly higher ADC tumor contrast (44.0%) than the CONV sequence (35.9%), (p<0.0012, Student's t-test). The rFOV sequence yielded significantly decreased susceptibility artifact and significantly higher contrast between tumor and healthy tissue.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ADC; Diffusion-weighted imaging; Endorectal; MRI; Prostate; Reduced FOV

Mesh:

Substances:

Year:  2014        PMID: 25200645      PMCID: PMC4342000          DOI: 10.1016/j.mri.2014.08.040

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  18 in total

1.  High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI).

Authors:  Eun-Kee Jeong; Seong-Eun Kim; Junyu Guo; Eugene G Kholmovski; Dennis L Parker
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

Review 2.  Transrectal ultrasound 1992.

Authors:  D Rickards
Journal:  Br J Urol       Date:  1992-05

3.  Diffusion imaging of the prostate at 3.0 tesla.

Authors:  Peter Gibbs; Martin D Pickles; Lindsay W Turnbull
Journal:  Invest Radiol       Date:  2006-02       Impact factor: 6.016

4.  DWI of the spinal cord with reduced FOV single-shot EPI.

Authors:  Emine Ulku Saritas; Charles H Cunningham; Jin Hyung Lee; Eric T Han; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

5.  A clinical comparison of rigid and inflatable endorectal-coil probes for MRI and 3D MR spectroscopic imaging (MRSI) of the prostate.

Authors:  Susan M Noworolski; Jason C Crane; Daniel B Vigneron; John Kurhanewicz
Journal:  J Magn Reson Imaging       Date:  2008-05       Impact factor: 4.813

6.  High-b-value diffusion-weighted imaging at 3 T to detect prostate cancer: comparisons between b values of 1,000 and 2,000 s/mm2.

Authors:  Chan Kyo Kim; Byung Kwan Park; Bohyun Kim
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

Review 7.  Imaging techniques for prostate cancer: implications for focal therapy.

Authors:  Baris Turkbey; Peter A Pinto; Peter L Choyke
Journal:  Nat Rev Urol       Date:  2009-04       Impact factor: 14.432

8.  Value of diffusion-weighted imaging for the prediction of prostate cancer location at 3T using a phased-array coil: preliminary results.

Authors:  Chan Kyo Kim; Byung Kwan Park; Hyun Moo Lee; Ghee Young Kwon
Journal:  Invest Radiol       Date:  2007-12       Impact factor: 6.016

Review 9.  Multiparametric magnetic resonance imaging in prostate cancer: present and future.

Authors:  John Kurhanewicz; Daniel Vigneron; Peter Carroll; Fergus Coakley
Journal:  Curr Opin Urol       Date:  2008-01       Impact factor: 2.309

10.  High b-value diffusion-weighted imaging in normal and malignant peripheral zone tissue of the prostate: effect of signal-to-noise ratio.

Authors:  Kazuhiro Kitajima; Yasushi Kaji; Kagayaki Kuroda; Kazuro Sugimura
Journal:  Magn Reson Med Sci       Date:  2008       Impact factor: 2.471

View more
  23 in total

1.  Comparison of field-of-view optimized and constrained undistorted single-shot diffusion-weighted imaging and conventional diffusion-weighted imaging of optic nerve and chiasma at 3T.

Authors:  Yuan Tian; Junqing Wang; Mingge Li; Xin Lou; Jing Tang; Quangang Xu; Yingkui Zhang; Shihui Wei; Lin Ma
Journal:  Neuroradiology       Date:  2018-07-19       Impact factor: 2.804

2.  Cervical Spinal Cord DTI Is Improved by Reduced FOV with Specific Balance between the Number of Diffusion Gradient Directions and Averages.

Authors:  A Crombe; N Alberti; B Hiba; M Uettwiller; V Dousset; T Tourdias
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-30       Impact factor: 3.825

3.  Reduced field-of-view diffusion-weighted MRI in patients with cervical cancer.

Authors:  Jiyoung Hwang; Seong Sook Hong; Hyun-Joo Kim; Yun-Woo Chang; Bo Da Nam; Eunsun Oh; EunJi Lee; Hwajin Cha
Journal:  Br J Radiol       Date:  2018-04-16       Impact factor: 3.039

4.  Preoperative staging of endometrial cancer using reduced field-of-view diffusion-weighted imaging: a preliminary study.

Authors:  Takashi Ota; Masatoshi Hori; Hiromitsu Onishi; Makoto Sakane; Takahiro Tsuboyama; Mitsuaki Tatsumi; Atsushi Nakamoto; Tadashi Kimura; Yoshifumi Narumi; Noriyuki Tomiyama
Journal:  Eur Radiol       Date:  2017-07-03       Impact factor: 5.315

5.  Stimulated echo based mapping (STEM) of T1 , T2 , and apparent diffusion coefficient: validation and protocol optimization.

Authors:  Yuxin Zhang; Shane A Wells; Diego Hernando
Journal:  Magn Reson Med       Date:  2018-07-19       Impact factor: 4.668

6.  Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging.

Authors:  Yuxin Zhang; James Holmes; Iñaki Rabanillo; Arnaud Guidon; Shane Wells; Diego Hernando
Journal:  Magn Reson Imaging       Date:  2018-04-17       Impact factor: 2.546

7.  Improved multiparametric MRI discrimination between low-risk prostate cancer and benign tissues in a small cohort of 5α-reductase inhibitor treated individuals as compared with an untreated cohort.

Authors:  Olga Starobinets; John Kurhanewicz; Susan M Noworolski
Journal:  NMR Biomed       Date:  2017-02-06       Impact factor: 4.044

8.  Accelerated imaging with segmented 2D pulses using parallel imaging and virtual coils.

Authors:  Michael Mullen; Alexander Gutierrez; Naoharu Kobayashi; Jarvis Haupt; Michael Garwood
Journal:  J Magn Reson       Date:  2019-07-04       Impact factor: 2.229

9.  Diffusion MRI using two-dimensional single-shot radial imaging (2D ss-rDWI) with variable flip angle and random view ordering.

Authors:  Kyle E Jeong; Edward W Hsu; Eun-Kee Jeong
Journal:  Magn Reson Imaging       Date:  2019-04-19       Impact factor: 2.546

10.  Pilot study of rapid MR pancreas screening for patients with BRCA mutation.

Authors:  Giuseppe Corrias; Mitchell C Raeside; Andrea Agostini; Sandra Huicochea-Castellanos; David Aramburu-Nunez; Ramesh Paudyal; Amita Shukla-Dave; Olga Smelianskaia; Marinela Capanu; Junting Zheng; Maggie Fung; David P Kelsen; Debra A Mangino; Mark E Robson; Deborah J Goldfrank; Jean Carter; Peter J Allen; Bettina Conti; Serena Monti; Richard K G Do; Lorenzo Mannelli
Journal:  Eur Radiol       Date:  2019-01-28       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.