Literature DB >> 23798360

Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging.

Seung-Kyun Lee1, Ek Tsoon Tan, Ambey Govenkar, Ileana Hancu.   

Abstract

PURPOSE: To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging.
METHODS: Dynamic slice-dependent update of linear shim and center frequency was implemented in a dual-echo B0 mapping sequence and a DW-EPI sequence. Multi-slice axial B0 maps and diffusion-weighted images were obtained from four volunteers with both conventional and dynamic shim methods. The two shim methods were compared in terms of B0 homogeneity and EPI pixel shift artifacts.
RESULTS: In all volunteers the B0 maps showed significantly improved homogeneity; the left-right asymmetry was reduced by 79% and within-slice B0 standard deviation was reduced by 20% on the average. The improvements were better than what was previously reported for conventional (static) third-order shim in bilateral breast. Anatomy-referenced apparent diffusion coefficient (ADC) maps showed reduced overall image registration error obtainable with dynamic shim.
CONCLUSIONS: Dynamic shim is an effective method to improve B0 shimming and DW-EPI image quality in 3 T bilateral breast imaging. Magn Reson Med 71:1813-1818, 2014. © 2013 Wiley Periodicals, Inc.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  DWI; EPI; breast; dynamic shim; susceptibility

Mesh:

Year:  2013        PMID: 23798360      PMCID: PMC3830606          DOI: 10.1002/mrm.24824

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Measurement and correction of respiration-induced B0 variations in breast 1H MRS at 4 Tesla.

Authors:  Patrick J Bolan; Pierre-Gilles Henry; Eva H Baker; Sina Meisamy; Michael Garwood
Journal:  Magn Reson Med       Date:  2004-12       Impact factor: 4.668

2.  On shimming approaches in 3T breast MRI.

Authors:  Ileana Hancu; Ambey Govenkar; Robert E Lenkinski; Seung-Kyun Lee
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

3.  Quantitative diffusion-weighted imaging as an adjunct to conventional breast MRI for improved positive predictive value.

Authors:  Savannah C Partridge; Wendy B DeMartini; Brenda F Kurland; Peter R Eby; Steven W White; Constance D Lehman
Journal:  AJR Am J Roentgenol       Date:  2009-12       Impact factor: 3.959

4.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

5.  Dynamic shim updating: a new approach towards optimized whole brain shimming.

Authors:  A M Blamire; D L Rothman; T Nixon
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

6.  Dynamic shimming for multi-slice magnetic resonance imaging.

Authors:  G Morrell; D Spielman
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

7.  Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging.

Authors:  F Farzaneh; S J Riederer; N J Pelc
Journal:  Magn Reson Med       Date:  1990-04       Impact factor: 4.668

8.  Pyrolytic graphite foam: a passive magnetic susceptibility matching material.

Authors:  Gary C Lee; Patrick W Goodwill; Kevin Phuong; Ben A Inglis; Greig C Scott; Brian A Hargreaves; Lizabeth Li; Alex C Chen; Rachana N Shah; Steven M Conolly
Journal:  J Magn Reson Imaging       Date:  2010-09       Impact factor: 4.813

9.  Patient-to-patient variation of susceptibility-induced B₀ field in bilateral breast MRI.

Authors:  Seung-Kyun Lee; Ileana Hancu
Journal:  J Magn Reson Imaging       Date:  2012-06-11       Impact factor: 4.813

10.  Magnetic field homogenization of the human prefrontal cortex with a set of localized electrical coils.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

View more
  12 in total

1.  Distortion correction in diffusion-weighted imaging of the breast: Performance assessment of prospective, retrospective, and combined (prospective + retrospective) approaches.

Authors:  Ileana Hancu; Seung-Kyun Lee; Keith Hulsey; Robert Lenkinski; Dominic Holland; Jonathan I Sperl; Ek T Tan
Journal:  Magn Reson Med       Date:  2016-07-12       Impact factor: 4.668

2.  High slew-rate head-only gradient for improving distortion in echo planar imaging: Preliminary experience.

Authors:  Ek T Tan; Seung-Kyun Lee; Paul T Weavers; Dominic Graziani; Joseph E Piel; Yunhong Shu; John Huston; Matt A Bernstein; Thomas K F Foo
Journal:  J Magn Reson Imaging       Date:  2016-02-26       Impact factor: 4.813

3.  Does integrated shimming improve lesion detection in whole-body diffusion-weighted examinations of patients with breast cancer?

Authors:  Michiro Sasaki; Mitsuhiro Tozaki; Katsuya Maruyama; Thomas Benkert; Wakana Murakami; Daisuke Yotsumoto; Shunichi Oosako; Yoshiaki Sagara
Journal:  Jpn J Radiol       Date:  2018-09-27       Impact factor: 2.374

4.  Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities.

Authors:  Sergios Gatidis; Hansjörg Graf; Jakob Weiß; Alto Stemmer; Berthold Kiefer; Konstantin Nikolaou; Mike Notohamiprodjo; Petros Martirosian
Journal:  MAGMA       Date:  2016-08-08       Impact factor: 2.310

Review 5.  Multiparametric MR Imaging of Breast Cancer.

Authors:  Habib Rahbar; Savannah C Partridge
Journal:  Magn Reson Imaging Clin N Am       Date:  2016-02       Impact factor: 2.266

6.  Variability and bias assessment in breast ADC measurement across multiple systems.

Authors:  Kathryn E Keenan; Adele P Peskin; Lisa J Wilmes; Sheye O Aliu; Ella F Jones; Wen Li; John Kornak; David C Newitt; Nola M Hylton
Journal:  J Magn Reson Imaging       Date:  2016-03-23       Impact factor: 4.813

7.  Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence.

Authors:  A Alhamud; Paul A Taylor; Andre J W van der Kouwe; Ernesta M Meintjes
Journal:  Neuroimage       Date:  2015-11-14       Impact factor: 6.556

8.  Denoising and Multiple Tissue Compartment Visualization of Multi-b-Valued Breast Diffusion MRI.

Authors:  Ek T Tan; Lisa J Wilmes; Bonnie N Joe; Natsuko Onishi; Vignesh A Arasu; Nola M Hylton; Luca Marinelli; David C Newitt
Journal:  J Magn Reson Imaging       Date:  2020-07-02       Impact factor: 4.813

9.  Whole-Body Diffusion-Weighted Imaging in Chronic Recurrent Multifocal Osteomyelitis in Children.

Authors:  Nadine Leclair; Gregor Thörmer; Ina Sorge; Lutz Ritter; Volker Schuster; Franz Wolfgang Hirsch
Journal:  PLoS One       Date:  2016-01-22       Impact factor: 3.240

10.  Bladder cancer: detection and image quality compared among iShim, RESOLVE, and ss-EPI diffusion-weighted MR imaging with high b value at 3.0 T MRI.

Authors:  Hongyi Li; Lin Liu; Qinglei Shi; Alto Stemmer; Hong Zeng; Yi Li; Mengchao Zhang
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.