Literature DB >> 29658386

Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners.

Steven P Mell1, Spencer Fullam1, Markus A Wimmer1, Hannah J Lundberg1.   

Abstract

Current treatment for end-stage osteoarthritis is total knee replacement. Given that the number of total knee replacement surgeries is expected to approach 3.48 million by 2030, understanding long-term failure is important. One of the preclinical tests for total knee replacements is carried out using mechanical wear testing under generic walking conditions. Used for this purpose is the International Standards Organization's generic walking profile. Recently this standard was updated by reversing the direction of anterior/posterior translation and internal/external rotation. The effects of this change have not been investigated, and therefore, it is unknown if comparisons between wear tests utilizing the old and new version of the standard are valid. In this study, we used a finite element model along with a frictional energy-based wear model to compare the kinematic inputs, contact conditions, and wear from the older and newer versions of the ISO standard. Simulator-tested components were used to validate the computational model. We found that there were no visible similarities in the contact conditions between the old and new versions of the standard. The new version of the standard had a lower wear rate but covered a larger portion of the articular surface. Locations of wear also varied considerably. The results of the study suggest that major differences between the old and new standard exist, and therefore, historical wear results should be compared with caution to newly obtained results.

Entities:  

Keywords:  Total knee arthroplasty; finite element modeling/analysis [medical]; knee prostheses; orthopedic materials; standardized testing; wear analysis/testing [biomechanics]

Mesh:

Substances:

Year:  2018        PMID: 29658386      PMCID: PMC6022396          DOI: 10.1177/0954411918770700

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  24 in total

1.  Constitutive modeling of ultra-high molecular weight polyethylene under large-deformation and cyclic loading conditions.

Authors:  J S Bergström; S M Kurtz; C M Rimnac; A A Edidin
Journal:  Biomaterials       Date:  2002-06       Impact factor: 12.479

2.  In vitro response of the natural cadaver knee to the loading profiles specified in a standard for knee implant wear testing.

Authors:  Levi G Sutton; Frederick W Werner; Hani Haider; Tracy Hamblin; Jonathan J Clabeaux
Journal:  J Biomech       Date:  2010-05-07       Impact factor: 2.712

3.  The global burden of hip and knee osteoarthritis: estimates from the global burden of disease 2010 study.

Authors:  Marita Cross; Emma Smith; Damian Hoy; Sandra Nolte; Ilana Ackerman; Marlene Fransen; Lisa Bridgett; Sean Williams; Francis Guillemin; Catherine L Hill; Laura L Laslett; Graeme Jones; Flavia Cicuttini; Richard Osborne; Theo Vos; Rachelle Buchbinder; Anthony Woolf; Lyn March
Journal:  Ann Rheum Dis       Date:  2014-02-19       Impact factor: 19.103

4.  An energy dissipation and cross shear time dependent computational wear model for the analysis of polyethylene wear in total knee replacements.

Authors:  Sean T O'Brien; Eric R Bohm; Martin J Petrak; Urs P Wyss; Jan-M Brandt
Journal:  J Biomech       Date:  2014-01-15       Impact factor: 2.712

Review 5.  Wear and osteolysis around total knee arthroplasty.

Authors:  Douglas D R Naudie; Deborah J Ammeen; Gerard A Engh; Cecil H Rorabeck
Journal:  J Am Acad Orthop Surg       Date:  2007-01       Impact factor: 3.020

6.  Cross-Shear in Metal-on-Polyethylene Articulation of Orthopaedic Implants and its Relationship to Wear.

Authors:  T Schwenke; M A Wimmer
Journal:  Wear       Date:  2013-04       Impact factor: 3.892

7.  In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard.

Authors:  V Ngai; T Schwenke; M A Wimmer
Journal:  Proc Inst Mech Eng H       Date:  2009-10       Impact factor: 1.617

Review 8.  Osteolysis after total knee arthroplasty.

Authors:  Sanjay K Gupta; Alice Chu; Amar S Ranawat; John Slamin; Chitranjan S Ranawat
Journal:  J Arthroplasty       Date:  2007-09       Impact factor: 4.757

9.  Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

Authors:  Valentina Ngai; Markus A Wimmer
Journal:  J Biomech       Date:  2009-08-03       Impact factor: 2.712

10.  The epidemiology of revision total knee arthroplasty in the United States.

Authors:  Kevin J Bozic; Steven M Kurtz; Edmund Lau; Kevin Ong; Vanessa Chiu; Thomas P Vail; Harry E Rubash; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2009-06-25       Impact factor: 4.176

View more
  2 in total

1.  The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.

Authors:  Steven P Mell; Markus A Wimmer; Hannah J Lundberg
Journal:  J Biomech       Date:  2019-03-23       Impact factor: 2.712

2.  Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters.

Authors:  Steven P Mell; Markus A Wimmer; Joshua J Jacobs; Hannah J Lundberg
Journal:  J Mech Behav Biomed Mater       Date:  2021-10-28
  2 in total