Literature DB >> 9001933

Tractive forces during rolling motion of the knee: implications for wear in total knee replacement.

M A Wimmer1, T P Andriacchi.   

Abstract

Wear at the polyethylene tibial plateau in total knee arthroplasty (TKR) is one of the primary concerns with these devices. The artificial bearing of a TKR has to sustain large forces while allowing the mobility for normal motion, typically, rolling, gliding and rotation. The tractive forces during the rolling motion at the knee joint were analyzed to determine which factors cause these forces to increase in TKR. The implications of these tractive forces to polyethylene wear were considered. Traction forces were calculated using a model of the knee to evaluate the effect of variations in the coefficient of friction, gait characteristics, antagonistic muscle contraction and patellofemoral mechanics. The model was limited to the sagittal plane motion of the femur on the tibia. The input for the model was the shape of the articulating surface, coefficient of friction, contact path, muscle anatomy and gait kinetics common to patients with a total knee replacement. The generation of tractive forces on the tibial polyethylene plateau was highly dependent on the static and dynamic coefficient of friction between the femur and the tibia. A peak tractive force of approximately 0.4 body weight was calculated with a peak normal force of 3.3 body weight. Tractive rolling occurred during most of stance phase when the static coefficient was 0.2. Alterations in gait patterns had a substantial effect on the generation of tractive forces at the knee joint. When an abnormal gait pattern (often seen following TKR) was input to the model the posteriorly directed tractive force on the tibial surface was reduced. It was also found that variations in muscle contractions associated with antagonistic muscle activity as well as the angle of pull of the patellar tendon affected the magnitude of tractive forces. The results of the study suggest that there are feasible conditions following total knee replacement which can lead to tractive forces during rolling motion at the tibiofemoral articulation that should be considered in the analysis of factors leading to polyethylene damage in total knee replacement.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9001933     DOI: 10.1016/s0021-9290(96)00112-1

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  Grand challenge competition to predict in vivo knee loads.

Authors:  Benjamin J Fregly; Thor F Besier; David G Lloyd; Scott L Delp; Scott A Banks; Marcus G Pandy; Darryl D D'Lima
Journal:  J Orthop Res       Date:  2011-12-12       Impact factor: 3.494

2.  In vitro investigation of the influence of tibial slope on quadriceps extension force after total knee arthroplasty.

Authors:  Sven Ostermeier; Christof Hurschler; Henning Windhagen; Christina Stukenborg-Colsman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-04-21       Impact factor: 4.342

3.  Surface damage versus tibial polyethylene insert conformity: a retrieval study.

Authors:  Markus A Wimmer; Michel P Laurent; Jeannie D Haman; Joshua J Jacobs; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

4.  Direct comparison of measured and calculated total knee replacement force envelopes during walking in the presence of normal and abnormal gait patterns.

Authors:  Hannah J Lundberg; Kharma C Foucher; Thomas P Andriacchi; Markus A Wimmer
Journal:  J Biomech       Date:  2012-01-28       Impact factor: 2.712

5.  Multibody dynamic simulation of knee contact mechanics.

Authors:  Yanhong Bei; Benjamin J Fregly
Journal:  Med Eng Phys       Date:  2004-11       Impact factor: 2.242

6.  Changes in knee kinematics reflect the articular geometry after arthroplasty.

Authors:  Anthony M J Bull; Oliver Kessler; Mahbub Alam; Andrew A Amis
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

7.  Concurrent prediction of muscle and tibiofemoral contact forces during treadmill gait.

Authors:  Trent M Guess; Antonis P Stylianou; Mohammad Kia
Journal:  J Biomech Eng       Date:  2014-02       Impact factor: 2.097

8.  Multibody muscle driven model of an instrumented prosthetic knee during squat and toe rise motions.

Authors:  Antonis P Stylianou; Trent M Guess; Mohammad Kia
Journal:  J Biomech Eng       Date:  2013-04       Impact factor: 2.097

9.  Fine tuning total knee replacement contact force prediction algorithms using blinded model validation.

Authors:  Hannah J Lundberg; Christopher Knowlton; Markus A Wimmer
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

10.  Analysis of friction between articular cartilage and polyvinyl alcohol hydrogel artificial cartilage.

Authors:  Feng Li; Anmin Wang; Chengtao Wang
Journal:  J Mater Sci Mater Med       Date:  2016-03-12       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.