Literature DB >> 23793881

Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography.

Shinichiro Ikuta1, Kazuhiro Kobuke, Yoshitaka Iwanaga, Yoshifumi Nakauchi, Kenji Yamaji, Shunichi Miyazaki.   

Abstract

Compared with the bare metal stent (BMS), suppression of neointimal growth in the sirolimus-eluting stent (SES) reduced restenosis at the cost of more exposed struts that could impose the risk of stent thrombosis. The present study was conducted to analyze neointimal coverage patterns of stents at a strut-level after implantation of BMS or SES with the use of optical coherence tomography (OCT). We enrolled 35 patients and analyzed neointimal coverage of every strut from 41 stents (BMS: n = 8, SES: n = 33) by using OCT at follow-up of the stent implantation. All of the 371 struts from eight BMSs were covered with ≥100 μm of neointima, while 19.8 and 3.5% of 3,478 struts from 33 SESs were uncovered (neointimal thickness of <10 μm) and malapposed, respectively. The histogram of neointimal thickness showed basically normal distribution in BMS but skewed in SES. No regional difference in neointimal thickness was observed in BMS (proximal, 535.7 ± 25.2 μm; body, 532.4 ± 17.0 μm; distal, 485.8 ± 27.0 μm). In SES, however, the body segment showed thinner neointima [median 40 μm (interquartile range (IQR) 10-90 μm)] than proximal [60 μm (IQR 10-140 μm), p < 0.001] or distal [50 μm (IQR 10-110 μm), p < 0.001] segment, while uncovered and malapposed struts were more frequent in the proximal and body segments. In conclusion, SES, compared with BMS, showed more suppressed neointimal growth with regional variation: neointimal thickness was the least in the body part while the ratio of exposed and malapposed struts was minimal in the distal segment. OCT was useful for a strut-level analysis of neointimal coverage over the whole stent.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23793881     DOI: 10.1007/s00380-013-0376-4

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  24 in total

1.  Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy.

Authors:  Eugène P McFadden; Eugenio Stabile; Evelyn Regar; Edouard Cheneau; Andrew T L Ong; Timothy Kinnaird; William O Suddath; Neil J Weissman; Rebecca Torguson; Kenneth M Kent; August D Pichard; Lowell F Satler; Ron Waksman; Patrick W Serruys
Journal:  Lancet       Date:  2004 Oct 23-29       Impact factor: 79.321

2.  Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation.

Authors:  Masamichi Takano; Shigenobu Inami; Ik-Kyung Jang; Masanori Yamamoto; Daisuke Murakami; Koji Seimiya; Takayoshi Ohba; Kyoichi Mizuno
Journal:  Am J Cardiol       Date:  2007-02-23       Impact factor: 2.778

3.  Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents.

Authors:  Matthias Pfisterer; Hans Peter Brunner-La Rocca; Peter T Buser; Peter Rickenbacher; Patrick Hunziker; Christian Mueller; Raban Jeger; Franziska Bader; Stefan Osswald; Christoph Kaiser
Journal:  J Am Coll Cardiol       Date:  2006-11-02       Impact factor: 24.094

4.  Remodeling of in-stent neointima, which became thinner and transparent over 3 years: serial angiographic and angioscopic follow-up.

Authors:  M Asakura; Y Ueda; S Nanto; A Hirayama; T Adachi; M Kitakaze; M Hori; K Kodama
Journal:  Circulation       Date:  1998-05-26       Impact factor: 29.690

5.  Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries.

Authors:  Jeffrey J Popma; Martin B Leon; Jeffrey W Moses; David R Holmes; Nicholas Cox; Michelle Fitzpatrick; John Douglas; Charles Lambert; Michael Mooney; Steven Yakubov; Richard E Kuntz
Journal:  Circulation       Date:  2004-12-13       Impact factor: 29.690

6.  Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure. - 6-month follow-up -.

Authors:  Naoki Miyoshi; Junya Shite; Toshiro Shinke; Hiromasa Otake; Yusuke Tanino; Daisuke Ogasawara; Takahiro Sawada; Hiroyuki Kawamori; Hiroki Kato; Naoki Yoshino; Amane Kozuki; Ken-ichi Hirata
Journal:  Circ J       Date:  2010-03-10       Impact factor: 2.993

7.  Angioscopic evaluation of neointima coverage: sirolimus drug-eluting stent versus bare metal stent.

Authors:  Jota Oyabu; Yasunori Ueda; Nobuyuki Ogasawara; Katsuki Okada; Atsushi Hirayama; Kazuhisa Kodama
Journal:  Am Heart J       Date:  2006-12       Impact factor: 4.749

Review 8.  Features and parameters of drug-eluting stent deployment discoverable by intravascular ultrasound.

Authors:  Gary S Mintz
Journal:  Am J Cardiol       Date:  2007-10-22       Impact factor: 2.778

Review 9.  Sirolimus and Paclitaxel on polymer-based drug-eluting stents: similar but different.

Authors:  Rainer Wessely; Albert Schömig; Adnan Kastrati
Journal:  J Am Coll Cardiol       Date:  2006-01-26       Impact factor: 24.094

Review 10.  Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting.

Authors:  Giulio Guagliumi; Vasile Sirbu
Journal:  Catheter Cardiovasc Interv       Date:  2008-08-01       Impact factor: 2.692

View more
  13 in total

1.  Comparison between drug-coated balloon angioplasty and second-generation drug-eluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation.

Authors:  In Sook Kang; Islam Shehata; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Heart Vessels       Date:  2015-09-04       Impact factor: 2.037

2.  Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.

Authors:  Daisuke Izumi; Masatoshi Miyahara; Naoki Fujimoto; Shusuke Fukuoka; Masataka Sakai; Kaoru Dohi; Masaaki Ito
Journal:  Heart Vessels       Date:  2015-09-03       Impact factor: 2.037

3.  Triple versus dual antiplatelet therapy after percutaneous coronary intervention for coronary bifurcation lesions: results from the COBIS (COronary BIfurcation Stent) II Registry.

Authors:  Pil Sang Song; Young Bin Song; Jeong Hoon Yang; Joo-Yong Hahn; Seung-Hyuk Choi; Jin-Ho Choi; Sang Hoon Lee; Hyo-Soo Kim; Yangsoo Jang; Ki Bae Seung; Ju Hyeon Oh; Hyeon-Cheol Gwon
Journal:  Heart Vessels       Date:  2014-03-30       Impact factor: 2.037

4.  Bioresorbable scaffolds for the treatment of in-stent restenosis.

Authors:  Oliver Dörr; Christoph Liebetrau; Jens Wiebe; Franziska Hecker; Johannes Rixe; Helge Möllmann; Christian Hamm; Holger Nef
Journal:  Heart Vessels       Date:  2014-01-04       Impact factor: 2.037

5.  Unusual peri-stent strut contrast staining 6 years after sirolimus-eluting stent implantation: an "ant colony-like" appearance.

Authors:  Yoji Neishi; Hiroyuki Okura; Kiyoshi Yoshida
Journal:  Heart Vessels       Date:  2013-11-07       Impact factor: 2.037

6.  A case of active peri-stent inflammation after sirolimus-eluting stent implantation.

Authors:  Takafumi Kurosawa; Jun-Ichi Kotani; Taka-aki Matsuyama; Hatsue Ishibashi-Ueda
Journal:  Heart Vessels       Date:  2014-01-10       Impact factor: 2.037

7.  Impact of drug-eluting balloon (pre- or post-) dilation on neointima formation in de novo lesions treated by bare-metal stent: the IN-PACT CORO trial.

Authors:  Francesco Burzotta; Marta Francesca Brancati; Carlo Trani; Giancarlo Pirozzolo; Gianluigi De Maria; Antonio Maria Leone; Giampaolo Niccoli; Italo Porto; Francesco Prati; Filippo Crea
Journal:  Heart Vessels       Date:  2015-04-12       Impact factor: 2.037

8.  Neointimal coverage and late apposition of everolimus-eluting bioresorbable scaffolds implanted in the acute phase of myocardial infarction: OCT data from the PRAGUE-19 study.

Authors:  Petr Toušek; Viktor Kočka; Martin Malý; Libor Lisa; Tomáš Buděšínský; Petr Widimský
Journal:  Heart Vessels       Date:  2015-04-21       Impact factor: 2.037

9.  Neointimal coverage of zotarolimus-eluting stent at 1, 2, and 3 months' follow-up: an optical coherence tomography study.

Authors:  Takehiro Hashikata; Taiki Tojo; Sayaka Namba; Lisa Kitasato; Takuya Hashimoto; Ryo Kameda; Takao Shimohama; Minako Yamaoka-Tojo; Junya Ako
Journal:  Heart Vessels       Date:  2014-11-02       Impact factor: 2.037

10.  Assessment of vascular response after drug-eluting stents implantation in patients with diabetes mellitus: an optical coherence tomography sub-study of the J-DESsERT.

Authors:  Takashi Kubo; Takashi Akasaka; Takashi Tanimoto; Masamichi Takano; Yoshitane Seino; Kenya Nasu; Tomonori Itoh; Kyoichi Mizuno; Hiroyuki Okura; Toshiro Shinke; Jun-Ichi Kotani; Shigenori Ito; Hiroyoshi Yokoi; Toshiya Muramatsu; Masato Nakamura; Shinsuke Nanto
Journal:  Heart Vessels       Date:  2015-01-29       Impact factor: 2.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.