Literature DB >> 26337620

Comparison between drug-coated balloon angioplasty and second-generation drug-eluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation.

In Sook Kang1, Islam Shehata2, Dong-Ho Shin1,3, Jung-Sun Kim1,3, Byeong-Keuk Kim1,3, Young-Guk Ko1,3, Donghoon Choi1,3, Yangsoo Jang1,3,4, Myeong-Ki Hong5,6,7.   

Abstract

Even though drug-coated balloon (DCB) angioplasty has emerged as a treatment option for drug-eluting stent in-stent restenosis (DES-ISR), the most effective treatment strategy for DES-ISR is still under debate. Therefore, we compared long-term clinical outcomes following DCB treatment of DES-ISR with those following 2nd-generation drug-eluting stent (DES) treatment. We identified 248 DES-ISR lesions in 238 patients that were treated with either 2nd-generation DES implantation (n = 56) or DCB angioplasty (n = 192). We compared the incidences of major adverse cardiac events (MACEs) in the two groups during the 2-year period following treatment. MACE was defined as cardiac death, non-fatal myocardial infarction, or target-vessel revascularization. The percentage of patients with diabetes and the mean age of patients in the DCB group were greater than in the DES group. The DCB group also had a smaller reference vessel diameter. The DES group had a larger post-intervention minimal luminal diameter. We found no significant difference in the MACE rate between the two groups during the 2 years following treatment (11.0 % in the DCB group vs. 8.9 % in the DES group, p = 0.660). Reference segment diameter was the only independent predictive factor for MACE in the post-treatment period (hazard ratio 0.35, 95 % confidence interval: 0.15-0.82, p = 0.016). Clinical efficacy of DCB angioplasty for treatment of DES-ISR was comparable to that of 2nd-generation DES implantation as measured by the rate of MACEs in the two groups. Reference segment diameter was the only statistically significant independent predictor for MACE in the 2-year period following treatment.

Entities:  

Keywords:  Angioplasty; Coronary artery disease; Restenosis; Stent

Mesh:

Substances:

Year:  2015        PMID: 26337620     DOI: 10.1007/s00380-015-0741-6

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  29 in total

1.  Treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter.

Authors:  Bruno Scheller; Christoph Hehrlein; Wolfgang Bocksch; Wolfgang Rutsch; Dariush Haghi; Ulrich Dietz; Michael Böhm; Ulrich Speck
Journal:  N Engl J Med       Date:  2006-11-13       Impact factor: 91.245

2.  Outcome differences with the use of drug-eluting stents for the treatment of in-stent restenosis of bare-metal stents versus drug-eluting stents.

Authors:  Daniel H Steinberg; Michael A Gaglia; Tina L Pinto Slottow; Probal Roy; Laurent Bonello; Axel De Labriolle; Gilles Lemesle; Rebecca Torguson; Kimberly Kineshige; Zhenyi Xue; William O Suddath; Kenneth M Kent; Lowell F Satler; Augusto D Pichard; Joseph Lindsay; Ron Waksman
Journal:  Am J Cardiol       Date:  2009-02-15       Impact factor: 2.778

3.  Paclitaxel-eluting balloon versus everolimus-eluting stent for treatment of drug-eluting stent restenosis.

Authors:  Mohammad Almalla; Jörg Schröder; Verena Pross; Nikolaus Marx; Rainer Hoffmann
Journal:  Catheter Cardiovasc Interv       Date:  2013-07-03       Impact factor: 2.692

4.  New stent implantation for recurrences after stenting for in-stent restenosis: implications of a third metal layer in human coronary arteries.

Authors:  Fernando Alfonso; Javier García; Maria-José Pérez-Vizcayno; Lorenzo Hernando; Rosana Hernandez; Javier Escaned; Pilar Jiménez-Quevedo; Camino Bañuelos; Carlos Macaya
Journal:  J Am Coll Cardiol       Date:  2009-09-08       Impact factor: 24.094

5.  Third universal definition of myocardial infarction.

Authors:  Kristian Thygesen; Joseph S Alpert; Allan S Jaffe; Maarten L Simoons; Bernard R Chaitman; Harvey D White; Kristian Thygesen; Joseph S Alpert; Harvey D White; Allan S Jaffe; Hugo A Katus; Fred S Apple; Bertil Lindahl; David A Morrow; Bernard R Chaitman; Peter M Clemmensen; Per Johanson; Hanoch Hod; Richard Underwood; Jeroen J Bax; Jeroen J Bonow; Fausto Pinto; Raymond J Gibbons; Keith A Fox; Dan Atar; L Kristin Newby; Marcello Galvani; Christian W Hamm; Barry F Uretsky; Ph Gabriel Steg; William Wijns; Jean-Pierre Bassand; Phillippe Menasche; Jan Ravkilde; E Magnus Ohman; Elliott M Antman; Lars C Wallentin; Paul W Armstrong; Maarten L Simoons; James L Januzzi; Markku S Nieminen; Mihai Gheorghiade; Gerasimos Filippatos; Russell V Luepker; Stephen P Fortmann; Wayne D Rosamond; Dan Levy; David Wood; Sidney C Smith; Dayi Hu; Jose-Luis Lopez-Sendon; Rose Marie Robertson; Douglas Weaver; Michal Tendera; Alfred A Bove; Alexander N Parkhomenko; Elena J Vasilieva; Shanti Mendis; Jeroen J Bax; Helmut Baumgartner; Claudio Ceconi; Veronica Dean; Christi Deaton; Robert Fagard; Christian Funck-Brentano; David Hasdai; Arno Hoes; Paulus Kirchhof; Juhani Knuuti; Philippe Kolh; Theresa McDonagh; Cyril Moulin; Bogdan A Popescu; Zeljko Reiner; Udo Sechtem; Per Anton Sirnes; Michal Tendera; Adam Torbicki; Alec Vahanian; Stephan Windecker; Joao Morais; Carlos Aguiar; Wael Almahmeed; David O Arnar; Fabio Barili; Kenneth D Bloch; Ann F Bolger; Hans Erik Botker; Biykem Bozkurt; Raffaele Bugiardini; Christopher Cannon; James de Lemos; Franz R Eberli; Edgardo Escobar; Mark Hlatky; Stefan James; Karl B Kern; David J Moliterno; Christian Mueller; Aleksandar N Neskovic; Burkert Mathias Pieske; Steven P Schulman; Robert F Storey; Kathryn A Taubert; Pascal Vranckx; Daniel R Wagner
Journal:  J Am Coll Cardiol       Date:  2012-09-05       Impact factor: 24.094

Review 6.  In-stent restenosis in the drug-eluting stent era.

Authors:  George D Dangas; Bimmer E Claessen; Adriano Caixeta; Elias A Sanidas; Gary S Mintz; Roxana Mehran
Journal:  J Am Coll Cardiol       Date:  2010-11-30       Impact factor: 24.094

7.  A prospective, multicenter, randomized trial of paclitaxel-coated balloon versus paclitaxel-eluting stent for the treatment of drug-eluting stent in-stent restenosis: results from the PEPCAD China ISR trial.

Authors:  Bo Xu; Runlin Gao; Jian'an Wang; Yuejin Yang; Shaoliang Chen; Bin Liu; Fang Chen; Zhanquan Li; Yaling Han; Guosheng Fu; Yelin Zhao; Junbo Ge
Journal:  JACC Cardiovasc Interv       Date:  2014-02       Impact factor: 11.195

8.  SeQuentPlease World Wide Registry: clinical results of SeQuent please paclitaxel-coated balloon angioplasty in a large-scale, prospective registry study.

Authors:  Jochen Wöhrle; Mariusz Zadura; Sven Möbius-Winkler; Matthias Leschke; Christian Opitz; Waqas Ahmed; Paul Barragan; Jean-Philippe Simon; Graham Cassel; Bruno Scheller
Journal:  J Am Coll Cardiol       Date:  2012-10-03       Impact factor: 24.094

9.  Long-term clinical outcomes after sirolimus-eluting stent implantation for treatment of restenosis within bare-metal versus drug-eluting stents.

Authors:  Cheol Whan Lee; Sang-Hyun Kim; Jon Suh; Duk-Woo Park; Seung-Hwan Lee; Young-Hak Kim; Myeong-Ki Hong; Jae-Joong Kim; Seong-Wook Park; Seung-Jung Park
Journal:  Catheter Cardiovasc Interv       Date:  2008-04-01       Impact factor: 2.692

10.  Incidence and predictors of restenosis after coronary stenting in 10 004 patients with surveillance angiography.

Authors:  Salvatore Cassese; Robert A Byrne; Tomohisa Tada; Susanne Pinieck; Michael Joner; Tareq Ibrahim; Lamin A King; Massimiliano Fusaro; Karl-Ludwig Laugwitz; Adnan Kastrati
Journal:  Heart       Date:  2013-11-22       Impact factor: 5.994

View more
  3 in total

Review 1.  Drug-Eluting Balloons versus Second-Generation Drug-Eluting Stents for Treating In-Stent Restenosis in Coronary Heart Disease after PCI: A Meta-Analysis.

Authors:  Wen-Juan Xiu; Hai-Tao Yang; Ying-Ying Zheng; Yi-Tong Ma; Xiang Xie
Journal:  Cardiol Res Pract       Date:  2018-07-24       Impact factor: 1.866

Review 2.  Drug-Eluting Balloon versus New-Generation Drug-Eluting Stent for the Treatment of In-Stent Restenosis: An Updated Systematic Review and Meta-Analysis.

Authors:  Kong-Yong Cui; Shu-Zheng Lyu; Min Zhang; Xian-Tao Song; Fei Yuan; Feng Xu
Journal:  Chin Med J (Engl)       Date:  2018-03-05       Impact factor: 2.628

3.  Value of S100A12 in predicting in-stent restenosis in patients with coronary drug-eluting stent implantation.

Authors:  Hengyi Liang; Yuqi Cui; Haoran Bu; Hang Liu; Pengcheng Yan; Lianqun Cui; Liming Chen
Journal:  Exp Ther Med       Date:  2020-05-06       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.