Literature DB >> 17437723

Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation.

Masamichi Takano1, Shigenobu Inami, Ik-Kyung Jang, Masanori Yamamoto, Daisuke Murakami, Koji Seimiya, Takayoshi Ohba, Kyoichi Mizuno.   

Abstract

Confirming complete neointimal coverage after implantation of a drug-eluting stent is clinically important because incomplete stent coverage is responsible for late thrombosis and sudden cardiac death. Optical coherence tomography is a high-resolution (approximately 10 microm) imaging technique capable of detecting a thin layer of neointimal hyperplasia (NIH) inside a sirolimus-eluting stent (SES) and stent malapposition. This investigation evaluated stent exposure and malapposition 3 months after SES implantation using optical coherence tomography in a different clinical presentations, such as acute coronary syndrome (ACS) and non-ACS. Motorized optical coherence tomographic pullback (1 mm/s) was performed at 3-month follow-up to examine consecutive implanted 31 SESs in 21 lesions in 21 patients (9 with ACS and 12 with non-ACS). NIH thickness inside each strut and percent NIH area in each cross section were measured. In total, 4,516 struts in 567-mm single-stented segments were analyzed. Overall, NIH thickness and percent NIH area were 29 +/- 41 microm and 10 +/- 4%, respectively. Rates of exposed struts and exposed struts with malapposition were 15% and 6%, respectively. These were more frequent in patients with ACS than in those with non-ACS (18% vs 13%, p <0.0001; 8% vs 5%, p <0.005, respectively). In conclusion, neointimal coverage over a SES at 3-month follow-up is incomplete in ACS and non-ACS. Our study suggests that dual antiplatelet therapy might be continued >3 months after SES implantation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17437723     DOI: 10.1016/j.amjcard.2006.11.068

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  39 in total

1.  Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation.

Authors:  Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

2.  Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.

Authors:  Daisuke Izumi; Masatoshi Miyahara; Naoki Fujimoto; Shusuke Fukuoka; Masataka Sakai; Kaoru Dohi; Masaaki Ito
Journal:  Heart Vessels       Date:  2015-09-03       Impact factor: 2.037

3.  Long-term (≥2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results.

Authors:  Tae-Hoon Kim; Jung-Sun Kim; Byoung-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2010-10-27       Impact factor: 2.357

4.  Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography.

Authors:  Shinichiro Ikuta; Kazuhiro Kobuke; Yoshitaka Iwanaga; Yoshifumi Nakauchi; Kenji Yamaji; Shunichi Miyazaki
Journal:  Heart Vessels       Date:  2013-06-21       Impact factor: 2.037

Review 5.  New X-ray imaging modalities and their integration with intravascular imaging and interventions.

Authors:  H Hetterich; T Redel; G Lauritsch; C Rohkohl; J Rieber
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-08       Impact factor: 2.357

6.  Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation.

Authors:  Byeong-Keuk Kim; Jung-Sun Kim; Changmyung Oh; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2011-05-31       Impact factor: 2.357

7.  Optical coherence tomographic comparison of neointimal coverage between sirolimus- and resolute zotarolimus-eluting stents at 9 months after stent implantation.

Authors:  Jung-Sun Kim; Jin-Sun Kim; Dong-Ho Shin; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2011-08-21       Impact factor: 2.357

8.  Correlation of angiographic late loss with neointimal coverage of drug-eluting stent struts on follow-up optical coherence tomography.

Authors:  Byeong-Keuk Kim; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2011-08-24       Impact factor: 2.357

9.  The initial extent of malapposition in ST-elevation myocardial infarction treated with drug-eluting stent: the usefulness of optical coherence tomography.

Authors:  Ung Kim; Jung-Sun Kim; Jin-Sun Kim; Jung-Myung Lee; Jung-Woo Son; Jaedeok Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang
Journal:  Yonsei Med J       Date:  2010-05       Impact factor: 2.759

10.  Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents.

Authors:  J-S Kim; I-K Jang; J-S Kim; T H Kim; M Takano; T Kume; N W Hur; Y-G Ko; D Choi; M-K Hong; Y Jang
Journal:  Heart       Date:  2009-06-16       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.