BACKGROUND: We asked whether cementless total hip arthroplasties that made use of alumina-on-highly cross-linked polyethylene bearings would improve hip score and functional activity and reduce the prevalence of polyethylene wear, osteolysis, and aseptic loosening. METHODS: Consecutive primary total hip arthroplasties were performed in fifty patients (a total of sixty hips among thirty-four men and sixteen women) who were younger than thirty years of age. The average age at the time of the index arthroplasty was 28.3 years (range, twenty-one to twenty-nine years). The average follow-up was 10.8 years (range, ten to twelve years). Osteolysis and polyethylene wear rates were evaluated with use of radiography and computed tomography. RESULTS: The mean Harris hip score, which was 38 points (range, 6 to 45 points) preoperatively, had improved to 95 points (range, 85 to 100 points) at a mean follow-up time of 10.8 years. The mean penetration (and standard error of the mean) of the polyethylene liner was 0.031 ± 0.004 mm per year. No hip had osteolysis or aseptic loosening. CONCLUSIONS: At a minimum of ten years and an average of 10.8 years postoperatively, the current generation of cementless acetabular and femoral components with alumina-on-highly cross-linked polyethylene bearings was functioning well and was not associated with the development of osteolysis in our group of patients younger than thirty years of age. While the long-term prevalence of polyethylene wear and osteolysis remains unknown, the midterm data are promising.
BACKGROUND: We asked whether cementless total hip arthroplasties that made use of alumina-on-highly cross-linked polyethylene bearings would improve hip score and functional activity and reduce the prevalence of polyethylene wear, osteolysis, and aseptic loosening. METHODS: Consecutive primary total hip arthroplasties were performed in fifty patients (a total of sixty hips among thirty-four men and sixteen women) who were younger than thirty years of age. The average age at the time of the index arthroplasty was 28.3 years (range, twenty-one to twenty-nine years). The average follow-up was 10.8 years (range, ten to twelve years). Osteolysis and polyethylene wear rates were evaluated with use of radiography and computed tomography. RESULTS: The mean Harris hip score, which was 38 points (range, 6 to 45 points) preoperatively, had improved to 95 points (range, 85 to 100 points) at a mean follow-up time of 10.8 years. The mean penetration (and standard error of the mean) of the polyethylene liner was 0.031 ± 0.004 mm per year. No hip had osteolysis or aseptic loosening. CONCLUSIONS: At a minimum of ten years and an average of 10.8 years postoperatively, the current generation of cementless acetabular and femoral components with alumina-on-highly cross-linked polyethylene bearings was functioning well and was not associated with the development of osteolysis in our group of patients younger than thirty years of age. While the long-term prevalence of polyethylene wear and osteolysis remains unknown, the midterm data are promising.
Authors: Jeffrey J Cherian; Julio J Jauregui; Samik Banerjee; Todd Pierce; Michael A Mont Journal: Clin Orthop Relat Res Date: 2015-02-26 Impact factor: 4.176
Authors: Jeffrey B Stambough; Gail Pashos; Ningying Wu; Jacob A Haynes; John M Martell; John C Clohisy Journal: J Arthroplasty Date: 2015-10-28 Impact factor: 4.757
Authors: Jeffrey B Stambough; Gail Pashos; Frank C Bohnenkamp; William J Maloney; John M Martell; John C Clohisy Journal: J Arthroplasty Date: 2015-07-17 Impact factor: 4.757
Authors: Jeremy T Hines; Woo Lam Jo; Quanjun Cui; Michael A Mont; Kyung Hoi Koo; Edward Y Cheng; Stuart B Goodman; Yong Chan Ha; Phillippe Hernigou; Lynne C Jones; Shin Yoon Kim; Takashi Sakai; Nobuhiko Sugano; Takuaki Yamamoto; Mel S Lee; Dewei Zhao; Wolf Drescher; Tae Young Kim; Young Kyun Lee; Byung Ho Yoon; Seung Hoon Baek; Wataru Ando; Hong Seok Kim; Jung Wee Park Journal: J Korean Med Sci Date: 2021-06-21 Impact factor: 2.153