Histopathology of the Clarion cochlear implant electrode positioner in a human subject.

M Seyyedi1, B J Burgess, D K Eddington, B J Gantz, J B Nadol.   

Abstract

A Silastic electrode positioner was introduced by the Advanced Bionics Corporation in 1999 and it was designed to achieve a perimodiolar position of the stimulating electrode. The positioner was voluntarily recalled in the United States in July 2002 due to an apparent higher risk of bacterial meningitis in patients in whom the electrode positioner had been placed. A detailed histopathologic study of the positioner in the human has not previously been published. The histopathologic findings in a 74-year-old woman who underwent bilateral cochlear implantation using the positioner are presented. Findings include a large track caused by the combined electrode and its positioner with considerable disruption of the basilar membrane and osseous spiral lamina. Although there was a fibrous sheath around the electrode and positioner at the cochleostomy in both ears, this fibrous sheath did not extend deeply into the cochlea except at the apical end of the electrode beyond the positioner. This resulted in a large fluid space around and between the positioner and electrode within the cochlea and presumably in fluid continuity with the cerebrospinal fluid space. Possible clinical implications are discussed.
Copyright © 2013 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2013        PMID: 23774789      PMCID: PMC4189082          DOI: 10.1159/000351300

Source DB:  PubMed          Journal:  Audiol Neurootol        ISSN: 1420-3030            Impact factor:   1.854


  15 in total

1.  Novel intracochlear electrode positioner: effects on electrode position.

Authors:  N W Yang; A V Hodges; T J Balkany
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  2000-12

2.  Perimodiolar electrodes in cochlear implant surgery.

Authors:  W K Gstoettner; O Adunka; P Franz; J Hamzavi; H Plenk; M Susani; W Baumgartner; J Kiefer
Journal:  Acta Otolaryngol       Date:  2001-01       Impact factor: 1.494

3.  Evaluation of the HiFocus electrode array with positioner in human temporal bones.

Authors:  Antje Aschendorff; Thomas Klenzner; Bernhard Richter; Ralf Kubalek; Heiner Nagursky; Roland Laszig
Journal:  J Laryngol Otol       Date:  2003-07       Impact factor: 1.469

4.  Clarion 1.2 standard electrode array with partial space-filling positioner: radiological and histological evaluation in human temporal bones.

Authors:  Bernhard Richter; Antje Aschendorff; Petra Lohnstein; Hartmut Husstedt; Heiner Nagursky; Roland Laszig
Journal:  J Laryngol Otol       Date:  2002-07       Impact factor: 1.469

5.  A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. II: Comparison of Spiral Clarion and HiFocus II electrodes.

Authors:  Peter Wardrop; David Whinney; Stephen J Rebscher; William Luxford; Patricia Leake
Journal:  Hear Res       Date:  2005-05       Impact factor: 3.208

6.  Effects of inner ear trauma on the risk of pneumococcal meningitis.

Authors:  Benjamin P C Wei; Robert K Shepherd; Roy M Robins-Browne; Graeme M Clark; Stephen J O'Leary
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2007-03

7.  Effects of the Clarion Electrode Positioning System on auditory thresholds and comfortable loudness levels in pediatric patients with cochlear implants.

Authors:  G S Donaldson; M D Peters; M R Ellis; B J Friedman; S C Levine; F L Rimell
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2001-08

8.  Electrically evoked compound action potential amplitude growth functions and HiResolution programming levels in pediatric CII implant subjects.

Authors:  Marc D Eisen; Kevin H Franck
Journal:  Ear Hear       Date:  2004-12       Impact factor: 3.570

9.  Risk of bacterial meningitis in children with cochlear implants.

Authors:  Jennita Reefhuis; Margaret A Honein; Cynthia G Whitney; Shadi Chamany; Eric A Mann; Krista R Biernath; Karen Broder; Susan Manning; Swati Avashia; Marcia Victor; Pamela Costa; Owen Devine; Ann Graham; Coleen Boyle
Journal:  N Engl J Med       Date:  2003-07-31       Impact factor: 91.245

Review 10.  Meningitis following cochlear implantation: pathomechanisms, clinical symptoms, conservative and surgical treatments.

Authors:  W Arnold; G Bredberg; W Gstöttner; J Helms; H Hildmann; T Kiratzidis; J Müller; R T Ramsden; P Roland; J N Walterspiel
Journal:  ORL J Otorhinolaryngol Relat Spec       Date:  2002 Nov-Dec       Impact factor: 1.538

View more
  2 in total

1.  Cochlear Histopathology as Observed in Two Patients With a Cochlear Implant Electrode With Positioner.

Authors:  Takefumi Kamakura; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2016-07       Impact factor: 2.311

2.  Silastic Electrode Positioner Extrusion as a Late Complication of Cochlear Implantation Surgery.

Authors:  Masoud Motasaddi Zarandy; Saman Rezaeian; Mina Motasaddizarandy
Journal:  J Int Adv Otol       Date:  2022-07       Impact factor: 1.316

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.